{"title":"Addressable Fire Alarm Panels","description":"\u003cp\u003eAddressable fire alarm panels connect detectors, manual call points, sounders and interface units on one or more loops. Every device has its own address, so the panel can show exactly which device has operated or developed a fault, rather than just a zone. That makes them well suited to offices, hotels, hospitals, schools and other larger or multi-storey buildings.\u003c\/p\u003e\u003cp\u003eThis range covers addressable panels from single-loop units up to 8-loop systems, from brands including Advanced, C-TEC, Kentec, Zeta, Ziton, EMS and FireClass. Loop counts appear in each product title, and many models list their protocol, such as Apollo, Hochiki ESP or C-TEC CAST.\u003c\/p\u003e\u003ch2\u003eChoosing an addressable panel\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops and devices:\u003c\/strong\u003e the number of devices per loop depends on the protocol, so check the panel's capacity against the design and allow spare addresses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e detectors and modules must use the panel's protocol. If you are matching existing devices, see \u003ca href=\"\/collections\/apollo\"\u003eApollo\u003c\/a\u003e or \u003ca href=\"\/collections\/ziton\"\u003eZiton\u003c\/a\u003e products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking and repeaters:\u003c\/strong\u003e larger sites may need \u003ca href=\"\/collections\/fire-alarm-repeater-panels\"\u003erepeater panels\u003c\/a\u003e or networked panels.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor smaller premises with simple zone-based layouts, see \u003ca href=\"\/collections\/conventional-fire-alarm-panels\"\u003econventional fire alarm panels\u003c\/a\u003e. The complete range is on the \u003ca href=\"\/collections\/fire-alarm-panels\"\u003efire alarm panels\u003c\/a\u003e page. Systems should be designed and commissioned by a competent person in line with BS 5839-1.\u003c\/p\u003e","products":[{"product_id":"nittan-evolution-1-single-loop-control-panel-with-touch-screen-display","title":"Nittan Evolution 1 Single Loop Control Panel Touch Screen Display (F12-83101)","description":"\u003cp\u003eThe Nittan evolution 1 (part no. F12-83101) is a single-loop analogue addressable fire alarm control panel with a 4.3-inch colour touch screen. It is fully compatible with the Nittan Evolution range of detection and alarm devices and is certified to EN 54-2 and EN 54-4.\u003c\/p\u003e\u003cp\u003eCause and effect can be set up on the panel itself or with the PC configuration tool and then downloaded. Panels can be networked, up to 16 in total, without extra hardware. The ABS enclosure has a fully removable front cover to make cabling and termination easier.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4.3-inch colour touch screen with an intuitive menu structure\u003c\/li\u003e\n\u003cli\u003eUp to 254 devices on the loop and 254 zones\u003c\/li\u003e\n\u003cli\u003eFull cause-and-effect programming at the panel or with the PC configuration tool\u003c\/li\u003e\n\u003cli\u003eNetwork up to 16 panels\u003c\/li\u003e\n\u003cli\u003e2 x configurable RS485 ports\u003c\/li\u003e\n\u003cli\u003eUp to 8 password-protected users\u003c\/li\u003e\n\u003cli\u003eSwitch-mode power supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMains supply: 230 V AC (+10% \/ -15%), 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOperating current: 1.0 A max.\u003c\/li\u003e\n\u003cli\u003eSystem voltage: 24 V DC nominal\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max.; loop length up to 2 km\u003c\/li\u003e\n\u003cli\u003eFire and fault relays: 1 x each, 230 V AC at 1 A\u003c\/li\u003e\n\u003cli\u003eEnclosure rating: IP30 (indoor use)\u003c\/li\u003e\n\u003cli\u003eConventional sounder outputs: 2 x 100 mA at 24 V DC\u003c\/li\u003e\n\u003cli\u003eCharger voltage: 27.6 V DC\u003c\/li\u003e\n\u003cli\u003eBatteries: up to 2 x 7.0 Ah 12 V DC sealed lead acid\u003c\/li\u003e\n\u003cli\u003eEnclosure: W 370 x H 311 x D 113 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 2.7 kg without batteries (7.35 kg with batteries)\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-2:1997 + A1:2006; EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNote: Nittan advises that panels with firmware 22.0.0 or newer cannot be networked with panels running firmware 21.09.05.20 or older.\u003c\/p\u003e","brand":"Nittan","offers":[{"title":"Default Title","offer_id":55107177906549,"sku":"F12-83101","price":330.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/NittanEvolution1SingleLoopControlPanelwithTouchScreenDisplay.png?v=1765896128"},{"product_id":"fireclass-fc602s-two-loop-addressable-fire-panel-557-200-650","title":"FireClass 557.200.650 FC602S Two Loop Addressable Fire Panel","description":"\u003cp\u003eFireClass FC602S Two Loop Addressable Fire Alarm Control Panel 557.200.650 The FireClass FC602S Two Loop Addressable Fire Alarm Control Panel (SKU: 557.200.650) is a compact, networkable fire alarm control panel designed for commercial and industrial fire detection systems. Featuring a shallow enclosure, intuitive colour LCD display and support for up to 250 addressable devices, it delivers reliable performance while simplifying installation, commissioning and day-to-day operation. Part of the trusted FireClass FC600 Series, the FC602S is built around the highly resilient FireClass loop protocol, offering dependable communication even in electrically noisy environments. The proven platform is shared with the FireClass FC700 range, providing outstanding reliability and flexibility for a wide variety of fire protection applications.\u003c\/p\u003e\n\u003ch3\u003eComponents \u0026amp; features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFireClass\u003c\/li\u003e\n  \u003cli\u003eFC602S addressable fire alarm control panel\u003c\/li\u003e\n  \u003cli\u003eManufacturer\u003c\/li\u003e\n  \u003cli\u003eSKU: 557.200.650 Supports two standard-power loops or one high-power loop\u003c\/li\u003e\n  \u003cli\u003eMaximum capacity of 250 addressable devices per panel\u003c\/li\u003e\n  \u003cli\u003eNetworkable architecture for larger fire alarm systems\u003c\/li\u003e\n  \u003cli\u003eHigh-resolution colour\u003c\/li\u003e\n  \u003cli\u003eLCD display for clear system status\u003c\/li\u003e\n  \u003cli\u003e32 dedicated zonal\u003c\/li\u003e\n  \u003cli\u003eLED indicators\u003c\/li\u003e\n  \u003cli\u003eCompact shallow housing for easier installation\u003c\/li\u003e\n  \u003cli\u003eSupports batteries up to 17Ah\u003c\/li\u003e\n  \u003cli\u003eBuilt on the proven\u003c\/li\u003e\n  \u003cli\u003eFC600 and FC700 hardware platform\u003c\/li\u003e\n  \u003cli\u003eHighly resistant to electrical interference and false alarm sources\u003c\/li\u003e\n  \u003cli\u003eDesigned for\u003c\/li\u003e\n  \u003cli\u003eReliable Fire\u003c\/li\u003e\n  \u003cli\u003eDetection The FC602S provides dependable operation using the advanced\u003c\/li\u003e\n  \u003cli\u003eCommercial\u003c\/li\u003e\n  \u003cli\u003eApplications\u003c\/li\u003e\n  \u003cli\u003eSuitable for offices, schools, healthcare facilities, retail premises, hotels, warehouses and other commercial buildings, the FireClass\u003c\/li\u003e\n  \u003cli\u003eFC602S offers a scalable solution that can expand alongside your fire detection requirements. Why\u003c\/li\u003e\n  \u003cli\u003eBuy from JEM UK? Competitive pricing on genuine\u003c\/li\u003e\n  \u003cli\u003eFireClass products\u003c\/li\u003e\n  \u003cli\u003eExpert technical support before and after purchase Fast\u003c\/li\u003e\n  \u003cli\u003eUK dispatch on stocked items\u003c\/li\u003e\n  \u003cli\u003eTrusted supplier of professional fire alarm equipment\u003c\/li\u003e\n  \u003cli\u003eDedicated customer service for installers and end users\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149648314741,"sku":"557.200.650","price":802.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/fireclass-default-title-fireclass-557-200-650-fc602s-two-loop-addressable-fire-panel-557-200-650-64081900208501.png?v=1766067448"},{"product_id":"fireclass-557-200-651-fc604s-four-loop-addressable-fire-panel","title":"FireClass 557.200.651 FC604S Four Loop Addressable Fire Panel","description":"\u003ch2\u003eFC604S 2-4 Loop FireClass Panel Shallow\u003c\/h2\u003e\n\u003cp\u003eThe FC604S is a four loop FireClass networkable panel with a shallow housing. This panel can have four standard-power loops or two high-power loops with each panel having a maximum of 500 addresses. It features a colour LCD display with 32 zonal LEDs, and has a maximum capacity of 17 Ah batteries.\u003c\/p\u003e\n\u003cp\u003eThe FC600 FireClass range is a powerful fire detection and alarm system that uses the robust FireClass loop protocol at its heart. The FireClass loop protocol was originally designed for operation in the most hostile of environments, therefore the system is highly resilient to external factors such as electrical noise, including interference from electrical signals from other devices, and sources of false alarm. The FC600 FireClass range uses the same hardware and software platform already well-known from the FC700 FireClass panel range.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149648675189,"sku":"557.200.651","price":981.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/fireclass-default-title-fireclass-557-200-651-fc604s-four-loop-addressable-fire-panel-557-200-651-64081892999541.png?v=1766067446"},{"product_id":"fireclass-557-200-719-fc501-l-triple-circuit-single-loop-panel-with-1-5a-psu","title":"FireClass 557.200.719 FC501-L Triple Circuit Single Loop Panel with 1.5A PSU","description":"\u003ch2\u003eFireClass 557.200.719 FC501-L Triple Circuit Single Loop Panel Icons - 1,5A PSU\u003c\/h2\u003e\n\u003cp\u003eFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use, the FC501 is an “out of the box” panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.\u003c\/p\u003e\n\u003cp\u003eAuto Addressing, Intelli-Zone, On line Help function, USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the instal­lation and configuration of the FC501 in just a few simple steps.\u003c\/p\u003e\n\u003cp\u003eThis 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones, according to the physical loop they are connected to, the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149651100021,"sku":"557.200.719","price":355.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/20250225_093506_2.jpg?v=1769533792"},{"product_id":"fireclass-557-200-949","title":"FireClass 557.200.949 FC702S 2 Loop Panel","description":"\u003cp\u003eThe FireClass FC702S (order number 557.200.949) is a 1-2 loop addressable fire control panel in a compact, shallow enclosure. It has a fully programmable 8.4-inch TFT colour touch-screen user interface with context-sensitive help and on-screen instructions, and it can be used with or without gloves.\u003c\/p\u003e\u003cp\u003eThe panel supports 250 addresses in total. Its addressable loop can be connected as one high power (HP) loop or as two shared power (SP) loops, so you can give all the power and 250 addresses to one loop or share them across two. FC702S panels can be networked together. The panel is certified to EN 54-2 and EN 54-4.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8.4-inch TFT colour touch-screen, multilingual user interface\u003c\/li\u003e\n\u003cli\u003eTouch-sensitive status LEDs with instant access to detailed event information\u003c\/li\u003e\n\u003cli\u003eUser-configurable on-screen site maps and programmable graphic quiescent display\u003c\/li\u003e\n\u003cli\u003eComprehensive point management and disable functions\u003c\/li\u003e\n\u003cli\u003e10,000-event log with dynamic filters\u003c\/li\u003e\n\u003cli\u003eKeyless log-on using RFID tags that identify and log user actions\u003c\/li\u003e\n\u003cli\u003eFlexible single or dual hardware loop configuration (1 HP or 2 SP loops)\u003c\/li\u003e\n\u003cli\u003eCompact shallow housing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOrder number: 557.200.949 (FC702S)\u003c\/li\u003e\n\u003cli\u003eLoops: 1 HP or 2 SP; up to 250 addresses per loop, 250 in total\u003c\/li\u003e\n\u003cli\u003eZonal LEDs: 16; zones supported: 240\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 480 x 410 x 140 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 9.7 kg (excluding batteries)\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 17 Ah\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230 V AC 50\/60 Hz; input current 1.6 A\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C; storage -20°C to +70°C; 90% RH non-condensing\u003c\/li\u003e\n\u003cli\u003eIP rating: IP30\u003c\/li\u003e\n\u003cli\u003eColour: RAL 7035 back box and door; RAL 7016 user interface surround\u003c\/li\u003e\n\u003cli\u003eEMC: EN 50130-4, EN 61000-6-3\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2, EN 54-4 (DoP-2018-4263; 2831-CPR-F2668; 0832-UKCA-CPR-F0388)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149655097717,"sku":"557.200.949","price":871.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/20250102_142556.jpg?v=1782723801"},{"product_id":"fireclass-557-200-951-fc708d-4-8-loop-touchscreen-fire-alarm-control-panel","title":"FireClass 557.200.951 FC708D 4-8 Loop Touchscreen Fire Alarm Control Panel","description":"\u003ch2\u003eFireClass 557.200.951 FC708D 4-8 Loop Touchscreen Fire Alarm Control Panel\u003c\/h2\u003e\n\u003cp\u003eThe FireClass range of fire alarm control panels provide a great deal of flexibility in terms of hardware configuration, scalability and feature set. They are easy to operate, easy to install, easy to service and provide the system designer with a wide range of practical engineering solutions. Remote connectivity and backwards compatibility make it a future proof investment with long term support and reduced life time cost.\u003c\/p\u003e\n\u003cp\u003eThe eight loop addressable panel from FireClass is a highly featured digital addressable fire alarm system with an advanced TFT colour touch-screen user interface that is ergonomically engineered specifically for fire alarm control. Operation of the touch screen is possible with or without gloves and provides easy-to-use, intuitive user controls including keyless log-on using RFID cards.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eErgonomic Icon Display - simple to operate user interface eliminates operator errors\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTouch sensitive status LEDs provide event summary information - instant access to detailed event information\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eContext sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser configurable on screen site maps - no need for additional site plans\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgrammable graphic quiescent display - opportunity for customer branding\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eComprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSelectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eKeyless log-on using RFID tags – identifies and logs user actions\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlexible single or dual hardware loop configurations - optimise loop power and address capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntegral slot card cage – easily expanded with a number of slot card options?\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149655720309,"sku":"557.200.951","price":1354.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/fireclass-control-panels-default-title-fireclass-557-200-951-fc708d-4-8-loop-touchscreen-fire-alarm-control-panel-557-200-951-64082164482421.jpg?v=1766067442"},{"product_id":"advanced-mx-5802a-2-8-loop-addressable-fire-control-panel-extended-core-protocol","title":"Advanced MX-5802A 2-8 Loop Addressable Fire Control Panel, Extended Core Protocol","description":"\u003cp\u003eThe Advanced MX-5802A\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 2 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 2 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (2 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332006424949,"sku":"MX-5802A\/FT","price":4236.04,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-control-panels-default-title-advanced-mx-5802a-2-8-loop-addressable-fire-control-panel-extended-core-protocol-mx-5802a-ft-66816182911349.jpg?v=1766068009"},{"product_id":"advanced-mx-5802-mxpro-5-series-2-8-loop-fire-control-panel-standard-network","title":"Advanced MX-5802 MxPro 5-Series 2-8 Loop Fire Control Panel Standard Network","description":"\u003cp\u003eThe Advanced MX-5802 is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 2 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 2 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (2 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332009013621,"sku":"MX-5802","price":4117.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5802-1_2.jpg?v=1771961081"},{"product_id":"advanced-mx-5101d-1-loop-fire-panel-deep-apo-hoch","title":"Advanced MX-5101D 1-Loop Fire Panel - Deep (Apo\/Hoch)","description":"\u003cp\u003eThe Advanced MX-5101D is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the large-deep enclosure, for use with Apollo (XP95 \/ Discovery) and Hochiki ESP protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApollo (XP95 \/ Discovery) and Hochiki ESP protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Apollo XP95 \/ Discovery and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 475 x 450 x 190mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 30 x top, 11 x rear, 3 x bottom (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 45Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023333237,"sku":"MX-5101D","price":1089.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5401-1_1.jpg?v=1771961053"},{"product_id":"advanced-mx-5101ad-1-loop-fire-panel-deep-coreprotocol","title":"Advanced MX-5101AD 1-Loop Fire Panel - Deep (CoreProtocol)","description":"\u003cp\u003eThe Advanced MX-5101AD is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the large-deep enclosure, for use with Apollo Soteria (CoreProtocol) protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003cp\u003eAdvanced specifies the MXP-568 loop driver card for Apollo Soteria.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApollo Soteria (CoreProtocol) protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Apollo Soteria (CoreProtocol); Advanced specifies the MXP-568 loop driver card for Soteria\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 475 x 450 x 190mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 30 x top, 11 x rear, 3 x bottom (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 45Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023366005,"sku":"MX-5101AD","price":977.55,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101ad-1-loop-fire-panel-deep-coreprotocol-mx-5101ad-66749851697525.webp?v=1766067978"},{"product_id":"advanced-mx-5101vd-1-loop-fire-panel-deep-argus","title":"Advanced MX-5101VD 1-Loop Fire Panel - Deep (Argus)","description":"\u003cp\u003eThe Advanced MX-5101VD is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the large-deep enclosure, for use with Argus Vega protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eArgus Vega protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Argus Vega\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 475 x 450 x 190mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 30 x top, 11 x rear, 3 x bottom (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 45Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023398773,"sku":"MX-5101VD","price":977.55,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101vd-1-loop-fire-panel-deep-argus-mx-5101vd-66749851926901.webp?v=1766067974"},{"product_id":"advanced-mx-5101nd-1-loop-fire-panel-deep-nittan","title":"Advanced MX-5101ND 1-Loop Fire Panel - Deep (Nittan)","description":"\u003cp\u003eThe Advanced MX-5101ND is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the large-deep enclosure, for use with Nittan Evolution protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNittan Evolution protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Nittan Evolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 475 x 450 x 190mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 30 x top, 11 x rear, 3 x bottom (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 45Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023431541,"sku":"MX-5101ND","price":977.55,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101nd-1-loop-fire-panel-deep-nittan-mx-5101nd-66749852156277.webp?v=1766067974"},{"product_id":"advanced-mx-5101l-1-loop-fire-panel-large-apo-hoch","title":"Advanced MX-5101L 1-Loop Fire Panel - Large (Apo\/Hoch)","description":"\u003cp\u003eThe Advanced MX-5101L is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the large enclosure, for use with Apollo (XP95 \/ Discovery) and Hochiki ESP protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApollo (XP95 \/ Discovery) and Hochiki ESP protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Apollo XP95 \/ Discovery and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 475 x 450 x 120mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 19 x top, 11 x rear, 2 x bottom (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 18Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023529845,"sku":"MX-5101L","price":1037.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5401-1.jpg?v=1771961051"},{"product_id":"advanced-mx-5101al-1-loop-fire-panel-large-coreprotocol","title":"Advanced MX-5101AL 1-Loop Fire Panel - Large (CoreProtocol)","description":"\u003cp\u003eThe Advanced MX-5101AL is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the large enclosure, for use with Apollo Soteria (CoreProtocol) protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003cp\u003eAdvanced specifies the MXP-568 loop driver card for Apollo Soteria.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApollo Soteria (CoreProtocol) protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Apollo Soteria (CoreProtocol); Advanced specifies the MXP-568 loop driver card for Soteria\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 475 x 450 x 120mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 19 x top, 11 x rear, 2 x bottom (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 18Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023562613,"sku":"MX-5101AL","price":930.67,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101al-1-loop-fire-panel-large-coreprotocol-mx-5101al-66749853139317.webp?v=1766067974"},{"product_id":"advanced-mx-5101vl-1-loop-fire-panel-large-argus","title":"Advanced MX-5101VL 1-Loop Fire Panel - Large (Argus)","description":"\u003cp\u003eThe Advanced MX-5101VL is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the large enclosure, for use with Argus Vega protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eArgus Vega protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Argus Vega\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 475 x 450 x 120mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 19 x top, 11 x rear, 2 x bottom (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 18Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023628149,"sku":"MX-5101VL","price":930.67,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101vl-1-loop-fire-panel-large-argus-mx-5101vl-66749853532533.webp?v=1766067973"},{"product_id":"advanced-mx-5101nl-1-loop-fire-panel-large-nittan","title":"Advanced MX-5101NL 1-Loop Fire Panel - Large (Nittan)","description":"\u003cp\u003eThe Advanced MX-5101NL is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the large enclosure, for use with Nittan Evolution protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNittan Evolution protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Nittan Evolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 475 x 450 x 120mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 19 x top, 11 x rear, 2 x bottom (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 18Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023693685,"sku":"MX-5101NL","price":1037.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101nl-1-loop-fire-panel-large-nittan-mx-5101nl-66749853761909.webp?v=1766067973"},{"product_id":"advanced-mx-5101m-1-loop-fire-panel-medium-apo-hoch","title":"Advanced MX-5101M 1-Loop Fire Panel - Medium (Apo\/Hoch)","description":"\u003cp\u003eThe Advanced MX-5101M is a single-loop MxPro 5 series analogue addressable fire alarm control panel in the medium enclosure, supplied with one loop driver card for Apollo (XP95 \/ Discovery) and Hochiki ESP devices.\u003c\/p\u003e\u003cp\u003eIt offers the same MxPro 5 graphical interface, cause-and-effect programming and optional peer-to-peer networking as the larger panels in the range, making it suitable for smaller sites and for nodes on larger networked systems.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle loop driver card supplied (Apollo XP95 \/ Discovery and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003e2 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default for full EN 54 compliance without additional hardware; up to 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003e8 programmable key switch inputs and space for the optional on-board printer (medium enclosure)\u003c\/li\u003e\n\u003cli\u003eOptional plug-in network card: MXP-503 (standard) or MXP-509 (fault-tolerant)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eNumber of loops: 1\u003c\/li\u003e\n\u003cli\u003eDevices per loop: protocol dependent\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 12 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eFire zones: 200 per panel; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 2 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 2 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 4 using MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 1 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable input: 1 x monitored on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 8\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 3 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 50-60 Hz (+10%, -15%), 1.0 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 1 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 12 Ah max\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial port: 1 x RS232; USB: 1 x type B\u003c\/li\u003e\n\u003cli\u003eEvent log: 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 345 x 430 x 120 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 17 x top, 11 x rear\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332024086901,"sku":"MX-5101M","price":986.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5201-1.jpg?v=1771961048"},{"product_id":"advanced-mx-5101am-1-loop-fire-panel-medium-coreprotocol","title":"Advanced MX-5101AM 1-Loop Fire Panel - Medium (CoreProtocol)","description":"\u003cp\u003eThe Advanced MX-5101AM is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the medium enclosure, for use with Apollo Soteria (CoreProtocol) protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003cp\u003eAdvanced specifies the MXP-568 loop driver card for Apollo Soteria.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApollo Soteria (CoreProtocol) protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Apollo Soteria (CoreProtocol); Advanced specifies the MXP-568 loop driver card for Soteria\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 345 x 430 x 120mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 17 x top, 11 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 12Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332024152437,"sku":"MX-5101AM","price":884.93,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101am-1-loop-fire-panel-medium-coreprotocol-mx-5101am-66749855629685.webp?v=1766067973"},{"product_id":"advanced-mx-5101vm-1-loop-fire-panel-medium-argus","title":"Advanced MX-5101VM 1-Loop Fire Panel - Medium (Argus)","description":"\u003cp\u003eThe Advanced MX-5101VM is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the medium enclosure, for use with Argus Vega protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to complex multi-area systems.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eArgus Vega protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and deep enclosures only)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Argus Vega\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; key switch inputs: 8 inputs (medium enclosure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 345 x 430 x 120mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 17 x top, 11 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 12Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332024250741,"sku":"MX-5101VM","price":986.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101vm-1-loop-fire-panel-medium-argus-mx-5101vm-66749856088437.webp?v=1766067973"},{"product_id":"advanced-mx-5101nm-1-loop-fire-panel-medium-nittan","title":"Advanced MX-5101NM 1-Loop Fire Panel - Medium (Nittan)","description":"\u003cp\u003eThe Advanced MX-5101NM is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the medium enclosure, for use with Nittan Evolution protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNittan Evolution protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eOptional on-board printer (medium, large and large-deep enclosures)\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Nittan Evolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 8 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 345 x 430 x 120mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 17 x top, 11 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 12Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332024349045,"sku":"MX-5101NM","price":884.93,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101nm-1-loop-fire-panel-medium-nittan-mx-5101nm-66749856317813.webp?v=1766067973"},{"product_id":"advanced-mx-5101-1-loop-fire-panel-small-apo-hoch","title":"Advanced MX-5101 1-Loop Fire Panel - Small (Apollo\/Hochiki)","description":"\u003cp\u003eThe Advanced MX-5101 is a single-loop MxPro 5 series addressable fire alarm control panel in the compact standard enclosure, for use with Apollo (XP95 \/ Discovery) and Hochiki ESP protocol devices. It brings the same interface, programming and networking capability as the larger MxPro 5 panels to smaller sites.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApollo (XP95 \/ Discovery) and Hochiki ESP protocol support\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel as standard, and up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming with dynamic zoning and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facilities for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote monitoring (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eUSB and RS232 ports for PC or modem connection; programmable from the keypad or with PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for expansion with option cards; add a network card for a peer-to-peer Ad-NeT network\u003c\/li\u003e\n\u003cli\u003e3 year manufacturer's warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (expandable to 4 with MXP-507)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz, 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 events and diagnostics plus 500 fire events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 345 x 345 x 85mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 7Ah maximum (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332025004405,"sku":"MX-5101","price":935.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5101-1_1.jpg?v=1771961047"},{"product_id":"advanced-mx-5101a-1-loop-fire-panel-small-coreprotocol","title":"Advanced MX-5101A 1-Loop Fire Panel - Small (CoreProtocol)","description":"\u003cp\u003eThe Advanced MX-5101A is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the standard (small) enclosure, for use with Apollo Soteria (CoreProtocol) protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to complex multi-area systems.\u003c\/p\u003e\u003cp\u003eAdvanced specifies the MXP-568 loop driver card for Apollo Soteria.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApollo Soteria (CoreProtocol) protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; key switch inputs: 1 volt-free input (standard enclosure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 345 x 345 x 85mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 13 x top, 8 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 7Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332025037173,"sku":"MX-5101A","price":839.17,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5101a-1-loop-fire-panel-small-coreprotocol-mx-5101a-66749861036405.webp?v=1766067972"},{"product_id":"advanced-mx-5101v-1-loop-fire-panel-small-argus","title":"Advanced MX-5101V 1-Loop Fire Panel - Small (Argus)","description":"\u003cp\u003eThe Advanced MX-5101V is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the standard (small) enclosure, for use with Argus Vega protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to complex multi-area systems.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eArgus Vega protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Argus Vega\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; key switch inputs: 1 volt-free input (standard enclosure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 345 x 345 x 85mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 13 x top, 8 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 7Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332025069941,"sku":"MX-5101V","price":935.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5101-1_3.jpg?v=1771961046"},{"product_id":"advanced-mx-5101n-1-loop-fire-panel-small-nittan","title":"Advanced MX-5101N 1-Loop Fire Panel - Small (Nittan)","description":"\u003cp\u003eThe Advanced MX-5101N is an MxPro 5 series single-loop analogue addressable fire alarm control panel in the standard (small) enclosure, for use with Nittan Evolution protocol devices. It is supplied with a single loop driver card, two on-board sounder circuits, 20 programmable zonal LEDs with slide-in labels and 25 system LEDs.\u003c\/p\u003e\u003cp\u003ePowerful cause-and-effect programming, dynamic zoning and enhanced trace diagnostics make it suitable for a wide range of sites, from small buildings to large, complex multi-area systems. It is compatible with AdvancedLive fire panel monitoring (UK and Ireland only).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNittan Evolution protocol support\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with real-time clock and enhanced trace diagnostics\u003c\/li\u003e\n\u003cli\u003eWhite backlit 240 x 64 graphical LCD with tactile alphanumeric keypad\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs\u003c\/li\u003e\n\u003cli\u003e4 programmable function buttons with LED confirmation\u003c\/li\u003e\n\u003cli\u003eUp to 200 fire zones per panel by default, allowing full EN 54 compliance without additional hardware; up to 2,000 zones when networked\u003c\/li\u003e\n\u003cli\u003eAuto-learn, loop detection and on-board scope facility for easier commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eDedicated USB and RS232 ports; programmable from the keypad or with PC-NeT-022 configuration software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with option cards\u003c\/li\u003e\n\u003cli\u003eOptional network card (MXP-503 standard or MXP-509 fault-tolerant) for peer-to-peer networking in a fault-tolerant loop or radial format\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Nittan Evolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e Protocol dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop current:\u003c\/strong\u003e 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 200 per panel, 2,000 networked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 x 1A programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 x 1A 30V AC\/DC programmable (10mA, 5V min), expandable to 4 with MXP-507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 1 x 24V 500mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 1 x monitored programmable input; programmable key switch inputs: 1 volt-free input (standard enclosure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 3A maximum (loop, sounders and auxiliary combined)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 200-240V AC 50-60Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e 1A, temperature compensated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10-Base-T \/ 100-Base-T (AdvancedLive connectivity, UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 1 x RS232, 1 x USB B type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent log:\u003c\/strong\u003e 5,000 event and diagnostic plus 500 fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 345 x 345 x 85mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 13 x top, 8 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 24V 4Ah minimum, 24V 7Ah maximum internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 95% RH max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332025102709,"sku":"MX-5101N","price":935.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5101-1_2.jpg?v=1771961045"},{"product_id":"advanced-mxm-028-termination-enclosure-1-4-loop-panel","title":"Advanced MXM-028 Termination Enclosure - 1-4 Loop Panel","description":"\u003cp\u003eThe Advanced MXM-028 is a terminal enclosure for the MxPro 4 series 1-4 loop fire alarm control panel (Mx-4400), listed by Advanced as \"Terminal enclosure - 1-4 loop panel\" in its MxPro 4 enclosures, doors and back boxes range.\u003c\/p\u003e\u003cp\u003eAdvanced's MxPro 4 metalwork is colour-matched to the MxPro range and is ideal for first fix installations or for housing matching third-party equipment. The MxPro 4 range is now listed as obsolete, so this item suits the maintenance of existing systems.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTerminal enclosure for the MxPro 4 1-4 loop panel\u003c\/li\u003e\n\u003cli\u003eColour-matched to the MxPro range\u003c\/li\u003e\n\u003cli\u003eIdeal for first fix\u003c\/li\u003e\n\u003cli\u003eNot suitable for use with MxPro 5 series metalwork\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart code:\u003c\/strong\u003e MXM-028\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer description:\u003c\/strong\u003e Terminal enclosure - 1-4 loop panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e MxPro 4 enclosures, doors and back boxes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e MxPro 4 series; not suitable for MxPro 5 series metalwork\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332031885685,"sku":"MXM-028","price":402.15,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mxm-028-termination-enclosure-1-4-loop-panel-mxm-028-66749884727669.webp?v=1766067967"},{"product_id":"ziton-zp3-series-zp3-2l-2-loop-analogue-control-panel-english-71401n","title":"ZITON ZP3 Series, ZP3-2L, 2-Loop Analogue Control Panel, English (71401N)","description":"\u003ch2\u003eZITON ZP3 Series, ZP3-2L, 2-loop analogue control panel, English (71401N)\u003c\/h2\u003e\n\u003cdiv class=\"o-grid__item u-2-of-2 u-1-of-2-bp4 js-match-description ng-star-inserted\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"align-second-content\"\u003e\n\u003cdiv class=\"c-checkout__section-text\"\u003e\n\u003cp class=\"u-font-small leaflet ng-star-inserted\"\u003eUp to 127 line devices (detectors, call points, sounders or interface units) may be connected to each of the ZP3 loops.\u003c\/p\u003e\n\u003cp class=\"u-font-small leaflet ng-star-inserted\"\u003eAll loop devices incorporate switch settings enabling them to be assigned a unique address, the location of which is pinpointed and polled by the panel every two seconds.\u003c\/p\u003e\n\u003cp class=\"u-font-small leaflet ng-star-inserted\"\u003eVariations in the detector's environment caused by increases of temperature or products of combustion are reported to the panel where they are processed and compared to known fire data prior to any alarm output being activated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul class=\"u-font-small\"\u003e\n\u003cli class=\"product-detail__key-feature ng-star-inserted\"\u003eCPR Certified to EN54:2 and 4\u003c\/li\u003e\n\u003cli class=\"product-detail__key-feature ng-star-inserted\"\u003eAdvanced sensing techniques\u003c\/li\u003e\n\u003cli class=\"product-detail__key-feature ng-star-inserted\"\u003eExtensive networking ability\u003c\/li\u003e\n\u003cli class=\"product-detail__key-feature ng-star-inserted\"\u003eLoop powered sounders support\u003c\/li\u003e\n\u003cli class=\"product-detail__key-feature ng-star-inserted\"\u003eEase of operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ziton","offers":[{"title":"Default Title","offer_id":56593238819189,"sku":"71401N","price":1323.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/71501.png?v=1792404180"},{"product_id":"morley-ias-722-001-301","title":"Morley-IAS 722-001-301 ZX1Se single loop control panel, 230Vac","description":"\u003cp\u003eZX1Se single loop control panel. 230Vac, 2 sounder circuits, 4 line display and networking capability. 400 x 400 x 135mm (H x W x D). Order loop cards separately. Languages supplied: English, Italian, Spanish, Portuguese, Polish, Dutch, Slovenian and Croatian. Supplied with 20 zonal LED's , not expandable\u003c\/p\u003e","brand":"Morley-IAS","offers":[{"title":"Default Title","offer_id":56706875523445,"sku":"722-001-301","price":941.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_e7e8eb5b-ba70-4d66-a465-402e5e1be00d.png?v=1770372970"},{"product_id":"notifier-europe-002-456","title":"Notifier Europe 002-456 ID60 single loop intelligent fire alarm panel","description":"\u003cp\u003eID60 single loop intelligent fire alarm panel. Supports VIEW™. Complete with 16 zonal LEDs, 4 programmable outputs, 1.5A power supply and space for 12Ah batteries. Black\/Grey. LPCB Approved. H:385mm W:380mm D:110mm\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706888401269,"sku":"002-456","price":781.9,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_c8b8984a-9a1f-4a69-b104-34c966fda4c2.png?v=1770373293"},{"product_id":"notifier-europe-002-461","title":"Notifier Europe 002-461 ID62 single loop intelligent fire alarm panel","description":"\u003cp\u003eID62 single loop intelligent fire alarm panel. Supports VIEW™. Complete with 16 zonal LEDs, 4 programmable outputs, separate 3A power supply, printer option and space for 42Ah batteries. Black\/Grey. LPCB approved. H:620mm W:500mm D:220mm\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706889613685,"sku":"002-461","price":1469.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_8108613d-4aef-4856-9a64-0997b031a1f7.png?v=1770373295"},{"product_id":"notifier-europe-002-463","title":"Notifier Europe 002-463 ID61 single loop intelligent fire alarm panel","description":"\u003cp\u003eID61 single loop intelligent fire alarm panel. Supports VIEW™. Complete with 16 zonal LEDs, 4 programmable outputs, separate 3A power supply, printer option and space for 12Ah batteries. Black\/Grey. LPCB approved. H:400mm W:500mm D:122mm\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706889646453,"sku":"002-463","price":1419.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_71202a9a-53bc-4510-ae9a-9b5c076ca924.png?v=1770373297"},{"product_id":"notifier-europe-002-474","title":"Notifier Europe 002-474 ID3002 Fixed 2 Loop Intelligent Fire Alarm Panel (No Zonal LEDs)","description":"\u003cp\u003eID3002 Fixed 2 loop intelligent fire alarm panel (No zonal LEDs), fully assembled. LPCB Approved. 3A PSU. Space for up to 12Ah batteries. H:400mm W:500mm D:122mm\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706889711989,"sku":"002-474","price":2335.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_f2c9fc7a-e11b-4426-8ec4-820ab3678afa.png?v=1770373302"},{"product_id":"notifier-europe-020-727","title":"Notifier 020-727 ID3000 4 LOOP Intelligent Fire Alarm Panel","description":"\u003ch2\u003eNotifier 020-727 ID3000 4 LOOP Intelligent Fire Alarm Panel with 4.5A power supply. LPCB approved. \u003c\/h2\u003e\n\u003cp\u003eKit includes: \u003cbr\u003e1 x 020-538 - Basic Equipment kit 2-8 Loops\u003cbr\u003e1 x 020-579 - 7A PSU 4.5A or 7A User selectable\u003cbr\u003e1 x 020-543  - Dual transmission path board kit\u003cbr\u003e1 x 020-588 - Dual loop board kit \u003cbr\u003e1 x 020-474-009 - Extended deep back-box kit\u003cbr\u003eSpace for up to 38Ah batteries. H:620mm W:500mm D:220mm.\u003cbr\u003e1 x 020-480-009 - Main cover kit\u003cbr\u003e1 x 020-485-009 - Extension cover blanking kit\u003cbr\u003e1 x 020-481-009 - Extension cover kit\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706896757109,"sku":"020-727","price":3759.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/020-727-400x400.jpg?v=1772476425"},{"product_id":"notifier-europe-020-730","title":"Notifier 020-730 ID3000 4 LOOP Intelligent Fire Alarm Panel","description":"\u003ch2\u003eNotifier 020-730 ID3000 4 LOOP Intelligent Fire Alarm Panel with 4.5A power supply and 64 ZONE LED user interface. LPCB approved.\u003c\/h2\u003e\n\u003cp\u003eKit includes:    \u003c\/p\u003e\n\u003cp\u003e1 x 020-538 - Basic Equipment kit 2-8 loops\u003cbr\u003e1 x 020-588 - Dual loop board kit \u003cbr\u003e1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable\u003cbr\u003e1 x 020-543  - Dual transmission path board kit \u003cbr\u003e1 x 020-474-009 - Extended deep back-box kit\u003cbr\u003eSpace for up to 38Ah batteries. H:620mm W:500mm D:220mm. \u003cbr\u003e1 x 020-480-009 - Main cover kit\u003cbr\u003e1 x 020-481-009 - Extension cover kit\u003cbr\u003e1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer \u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706896822645,"sku":"020-730","price":3661.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/020-730-400x400.jpg?v=1772476273"},{"product_id":"notifier-europe-020-734","title":"Notifier Europe 020-734 ID3000 6 LOOP intelligent fire alarm panel","description":"\u003cp\u003eID3000 6 LOOP intelligent fire alarm panel with 4.5A power supply and 64 ZONE LED user interface. LPCB approved. Kit includes:  \u003cbr\u003e\n1 x 020-538 - Basic Equipment kit 2-8 loops\u003cbr\u003e\n2 x 020-588 - Dual loop board kit\u003cbr\u003e\n1 x 020-579 - PSU 7A power supply . 4.5A or 7A user selectable\u003cbr\u003e\n1 x 020-543  - Dual transmission path board kit \u003cbr\u003e\n1 x 020-474-009 - Extended deep back-box kit \u003cbr\u003e\nSpace for up to 38Ah batteries. H:620mm W:500mm D:220mm.\u003cbr\u003e\n1 x 020-480-009 - Main cover kit\u003cbr\u003e\n1 x 020-481-009 - Extension cover kit\u003cbr\u003e\n1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706896855413,"sku":"020-734","price":4100.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_12465303-4477-4daf-8225-b5b2f09b4982.png?v=1770373419"},{"product_id":"notifier-europe-020-738","title":"Notifier Europe 020-738 ID3000 8 LOOP intelligent fire alarm panel","description":"\u003cp\u003eID3000 8 LOOP intelligent fire alarm panel with 7A power supply and 64 ZONE LED user interface. LPCB approved. Kit includes:\u003cbr\u003e\n1 x 020-538 - Basic Equipment kit 2-8 loops\u003cbr\u003e\n3 x 020-588 - Dual loop board kit\u003cbr\u003e\n1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable\u003cbr\u003e\n1 x 020-543  - Dual transmission path board kit\u003cbr\u003e\n1x 020-548 - Optional status indicator board kit for 7A PSU\u003cbr\u003e\n1 x 020-473-009 - Extended back-box kit\u003cbr\u003e\nSpace for up to 17Ah batteries. H:620mm W:500mm D:122mm. \u003cbr\u003e\n1 x 020-480-009 - Main cover kit\u003cbr\u003e\n1 x 020-481-009 - Extension cover kit\u003cbr\u003e\n1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer\u003cbr\u003e\n1 x 020-541-009 - 7A PSU\/78Ah battery cabinet kit\u003cbr\u003e\nPSU: H:510mm W:680mm D:241mm\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706896920949,"sku":"020-738","price":4874.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_4dd9703c-43ad-4a78-bd89-650ad51056b6.png?v=1770373421"},{"product_id":"notifier-europe-prl-led-en","title":"Notifier PRL-LED-EN Pearl Addressable Fire Alarm Panel (2-Loop)","description":"\u003cp\u003ePearl fixed 2 loop intelligent fire alarm panel complete with 64 zonal LEDs. Space for up to 12Ah batteries. H:355mm W:436mm D:142mm\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706913141109,"sku":"PRL-LED-EN","price":1604.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_fc63283f-ca4d-4142-9bf5-756997bd680d.png?v=1770373915"},{"product_id":"notifier-europe-prl-led-en-1","title":"Notifier PRL-LED-EN-1 Pearl Addressable Fire Alarm Panel (1-Loop)","description":"\u003cp\u003ePearl fixed 1 loop intelligent fire alarm panel complete with 64 zonal LEDs. Space for up to 12Ah batteries. H:355mm W:436mm D:142mm\u003c\/p\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706913239413,"sku":"PRL-LED-EN-1","price":1270.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_1aa5d9b1-9d65-4777-8fe0-2eb0c7e82b8d.png?v=1770373916"},{"product_id":"kentec-syncro-asm-1-loop-marine-approved-addressable-fire-panel-apollo-protocol-ma80161m2","title":"Kentec Syncro ASM 1 Loop Marine Approved Addressable Fire Panel - Apollo Protocol (MA80161M2)","description":"\u003cp\u003eThe Kentec Syncro ASM MA80161M2 is a marine and offshore analogue addressable fire alarm control panel for the Apollo Discovery protocol. It has 16 zones and one detection loop, expandable to two. Based on the Syncro AS panel, the Syncro ASM is Marine Equipment Directive approved and is certified with a number of classification societies. It suits small to medium-sized vessels and works with marine-approved Apollo devices.\u003c\/p\u003e\u003cp\u003eUp to 64 Syncro ASM panels can be networked, giving integrated control and indication of more than 16,000 fire alarm points. An optional Voyage Data Recorder interface, which outputs the standard NMEA 0183 protocol, can be fitted inside any panel on the network.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBased on the Syncro AS 1-2 loop analogue addressable panel\u003c\/li\u003e\n\u003cli\u003eMarine Equipment Directive approved and certified with a number of classification societies\u003c\/li\u003e\n\u003cli\u003eNetwork up to 64 panels (optional fault-tolerant network card)\u003c\/li\u003e\n\u003cli\u003e2 programmable sounder circuits, 5 programmable inputs and 3 programmable relays\u003c\/li\u003e\n\u003cli\u003e3 A power supply\u003c\/li\u003e\n\u003cli\u003eSensitivity adjustment and drift compensation\u003c\/li\u003e\n\u003cli\u003eCompatible with Syncro View Marine repeaters\u003c\/li\u003e\n\u003cli\u003eEvent log of the last 500 events\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly removable equipment chassis\u003c\/li\u003e\n\u003cli\u003eApproved and certified to EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: MA80161M2\u003c\/li\u003e\n\u003cli\u003eProtocol: Apollo Discovery\u003c\/li\u003e\n\u003cli\u003eZones: 16; loops: 1\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30\u003c\/li\u003e\n\u003cli\u003eColour: BS 00 A 05 grey lid and box; RAL 7047 light grey control plates\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 310 x 90 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 6 kg (standard panel)\u003c\/li\u003e\n\u003cli\u003eDisplay: 8 lines of 40 characters graphic LCD\u003c\/li\u003e\n\u003cli\u003ePower supply: 24 V DC, 3 A; mains fuse 1.6 A 250 V\u003c\/li\u003e\n\u003cli\u003eBatteries: max. 2 x 12 V 7 Ah (non-networked)\u003c\/li\u003e\n\u003cli\u003eAux 25 V supply: fused at 500 mA\u003c\/li\u003e\n\u003cli\u003eSounder outputs: fused at 1 A each\u003c\/li\u003e\n\u003cli\u003eFault, fire and alarm contacts: 30 V DC 1 A\u003c\/li\u003e\n\u003cli\u003eDetection loop: 400 mA output\u003c\/li\u003e\n\u003cli\u003eRemote inputs (switched -ve): silence, fault, reset, alert and evacuate\u003c\/li\u003e\n\u003cli\u003ePorts: RS232 printer and PC ports; RS485 serial expansion port for Syncro I\/O modules\u003c\/li\u003e\n\u003cli\u003eConfiguration: Loop Explorer PC utility (S187 standard or X187LS economy download lead)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784782918005,"sku":"MA80161M2","price":689.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroasm-1.jpg?v=1771967722"},{"product_id":"kentec-syncro-asm-1-loop-marine-approved-addressable-fire-panel-hochiki-protocol-mh80161m2","title":"Kentec Syncro ASM 1 Loop Marine Approved Addressable Fire Panel - Hochiki Protocol (MH80161M2)","description":"\u003cp\u003eThe Kentec Syncro ASM MH80161M2 is a marine and offshore analogue addressable fire alarm control panel for the Hochiki ESP protocol. It has 16 zones and one detection loop, expandable to two. Based on the Syncro AS panel, the Syncro ASM is Marine Equipment Directive approved and is certified with a number of classification societies. It suits small to medium-sized vessels and works with marine-approved Hochiki devices.\u003c\/p\u003e\u003cp\u003eUp to 64 Syncro ASM panels can be networked, giving integrated control and indication of more than 16,000 fire alarm points. An optional Voyage Data Recorder interface, which outputs the standard NMEA 0183 protocol, can be fitted inside any panel on the network.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBased on the Syncro AS 1-2 loop analogue addressable panel\u003c\/li\u003e\n\u003cli\u003eMarine Equipment Directive approved and certified with a number of classification societies\u003c\/li\u003e\n\u003cli\u003eNetwork up to 64 panels (optional fault-tolerant network card)\u003c\/li\u003e\n\u003cli\u003e2 programmable sounder circuits, 5 programmable inputs and 3 programmable relays\u003c\/li\u003e\n\u003cli\u003e3 A power supply\u003c\/li\u003e\n\u003cli\u003eSensitivity adjustment and drift compensation\u003c\/li\u003e\n\u003cli\u003eCompatible with Syncro View Marine repeaters\u003c\/li\u003e\n\u003cli\u003eEvent log of the last 500 events\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly removable equipment chassis\u003c\/li\u003e\n\u003cli\u003eApproved and certified to EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: MH80161M2\u003c\/li\u003e\n\u003cli\u003eProtocol: Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eZones: 16; loops: 1\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30\u003c\/li\u003e\n\u003cli\u003eColour: BS 00 A 05 grey lid and box; RAL 7047 light grey control plates\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 310 x 90 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 6 kg (standard panel)\u003c\/li\u003e\n\u003cli\u003eDisplay: 8 lines of 40 characters graphic LCD\u003c\/li\u003e\n\u003cli\u003ePower supply: 24 V DC, 3 A; mains fuse 1.6 A 250 V\u003c\/li\u003e\n\u003cli\u003eBatteries: max. 2 x 12 V 7 Ah (non-networked)\u003c\/li\u003e\n\u003cli\u003eAux 25 V supply: fused at 500 mA\u003c\/li\u003e\n\u003cli\u003eSounder outputs: fused at 1 A each\u003c\/li\u003e\n\u003cli\u003eFault, fire and alarm contacts: 30 V DC 1 A\u003c\/li\u003e\n\u003cli\u003eDetection loop: 400 mA output\u003c\/li\u003e\n\u003cli\u003eRemote inputs (switched -ve): silence, fault, reset, alert and evacuate\u003c\/li\u003e\n\u003cli\u003ePorts: RS232 printer and PC ports; RS485 serial expansion port for Syncro I\/O modules\u003c\/li\u003e\n\u003cli\u003eConfiguration: Loop Explorer PC utility (S187 standard or X187LS economy download lead)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784783049077,"sku":"MH80161M2","price":689.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroasm-1_1.jpg?v=1771967724"},{"product_id":"kentec-syncro-asm-2-loop-marine-approved-addressable-fire-panel-apollo-protocol-ma80162m2","title":"Kentec Syncro ASM 2 Loop Marine Approved Addressable Fire Panel - Apollo Protocol (MA80162M2)","description":"\u003cp\u003eThe Kentec Syncro ASM MA80162M2 is a marine and offshore analogue addressable fire alarm control panel for the Apollo Discovery protocol. It has 16 zones and two detection loops. Based on the Syncro AS panel, the Syncro ASM is Marine Equipment Directive approved and is certified with a number of classification societies. It suits small to medium-sized vessels and works with marine-approved Apollo devices.\u003c\/p\u003e\u003cp\u003eUp to 64 Syncro ASM panels can be networked, giving integrated control and indication of more than 16,000 fire alarm points. An optional Voyage Data Recorder interface, which outputs the standard NMEA 0183 protocol, can be fitted inside any panel on the network.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBased on the Syncro AS 1-2 loop analogue addressable panel\u003c\/li\u003e\n\u003cli\u003eMarine Equipment Directive approved and certified with a number of classification societies\u003c\/li\u003e\n\u003cli\u003eNetwork up to 64 panels (optional fault-tolerant network card)\u003c\/li\u003e\n\u003cli\u003e2 programmable sounder circuits, 5 programmable inputs and 3 programmable relays\u003c\/li\u003e\n\u003cli\u003e3 A power supply\u003c\/li\u003e\n\u003cli\u003eSensitivity adjustment and drift compensation\u003c\/li\u003e\n\u003cli\u003eCompatible with Syncro View Marine repeaters\u003c\/li\u003e\n\u003cli\u003eEvent log of the last 500 events\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly removable equipment chassis\u003c\/li\u003e\n\u003cli\u003eApproved and certified to EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: MA80162M2\u003c\/li\u003e\n\u003cli\u003eProtocol: Apollo Discovery\u003c\/li\u003e\n\u003cli\u003eZones: 16; loops: 2\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30\u003c\/li\u003e\n\u003cli\u003eColour: BS 00 A 05 grey lid and box; RAL 7047 light grey control plates\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 310 x 90 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 6 kg (standard panel)\u003c\/li\u003e\n\u003cli\u003eDisplay: 8 lines of 40 characters graphic LCD\u003c\/li\u003e\n\u003cli\u003ePower supply: 24 V DC, 3 A; mains fuse 1.6 A 250 V\u003c\/li\u003e\n\u003cli\u003eBatteries: max. 2 x 12 V 7 Ah (non-networked)\u003c\/li\u003e\n\u003cli\u003eAux 25 V supply: fused at 500 mA\u003c\/li\u003e\n\u003cli\u003eSounder outputs: fused at 1 A each\u003c\/li\u003e\n\u003cli\u003eFault, fire and alarm contacts: 30 V DC 1 A\u003c\/li\u003e\n\u003cli\u003eDetection loop: 400 mA output\u003c\/li\u003e\n\u003cli\u003eRemote inputs (switched -ve): silence, fault, reset, alert and evacuate\u003c\/li\u003e\n\u003cli\u003ePorts: RS232 printer and PC ports; RS485 serial expansion port for Syncro I\/O modules\u003c\/li\u003e\n\u003cli\u003eConfiguration: Loop Explorer PC utility (S187 standard or X187LS economy download lead)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784783343989,"sku":"MA80162M2","price":984.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroasm-1_2.jpg?v=1771967729"},{"product_id":"kentec-syncro-asm-2-loop-marine-approved-addressable-fire-panel-hochiki-protocol-mh80162m2","title":"Kentec Syncro ASM 2 Loop Marine Approved Addressable Fire Panel - Hochiki Protocol (MH80162M2)","description":"\u003cp\u003eThe Kentec Syncro ASM MH80162M2 is a marine and offshore analogue addressable fire alarm control panel for the Hochiki ESP protocol. It has 16 zones and two detection loops. Based on the Syncro AS panel, the Syncro ASM is Marine Equipment Directive approved and is certified with a number of classification societies. It suits small to medium-sized vessels and works with marine-approved Hochiki devices.\u003c\/p\u003e\u003cp\u003eUp to 64 Syncro ASM panels can be networked, giving integrated control and indication of more than 16,000 fire alarm points. An optional Voyage Data Recorder interface, which outputs the standard NMEA 0183 protocol, can be fitted inside any panel on the network.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBased on the Syncro AS 1-2 loop analogue addressable panel\u003c\/li\u003e\n\u003cli\u003eMarine Equipment Directive approved and certified with a number of classification societies\u003c\/li\u003e\n\u003cli\u003eNetwork up to 64 panels (optional fault-tolerant network card)\u003c\/li\u003e\n\u003cli\u003e2 programmable sounder circuits, 5 programmable inputs and 3 programmable relays\u003c\/li\u003e\n\u003cli\u003e3 A power supply\u003c\/li\u003e\n\u003cli\u003eSensitivity adjustment and drift compensation\u003c\/li\u003e\n\u003cli\u003eCompatible with Syncro View Marine repeaters\u003c\/li\u003e\n\u003cli\u003eEvent log of the last 500 events\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly removable equipment chassis\u003c\/li\u003e\n\u003cli\u003eApproved and certified to EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: MH80162M2\u003c\/li\u003e\n\u003cli\u003eProtocol: Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eZones: 16; loops: 2\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30\u003c\/li\u003e\n\u003cli\u003eColour: BS 00 A 05 grey lid and box; RAL 7047 light grey control plates\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 310 x 90 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 6 kg (standard panel)\u003c\/li\u003e\n\u003cli\u003eDisplay: 8 lines of 40 characters graphic LCD\u003c\/li\u003e\n\u003cli\u003ePower supply: 24 V DC, 3 A; mains fuse 1.6 A 250 V\u003c\/li\u003e\n\u003cli\u003eBatteries: max. 2 x 12 V 7 Ah (non-networked)\u003c\/li\u003e\n\u003cli\u003eAux 25 V supply: fused at 500 mA\u003c\/li\u003e\n\u003cli\u003eSounder outputs: fused at 1 A each\u003c\/li\u003e\n\u003cli\u003eFault, fire and alarm contacts: 30 V DC 1 A\u003c\/li\u003e\n\u003cli\u003eDetection loop: 400 mA output\u003c\/li\u003e\n\u003cli\u003eRemote inputs (switched -ve): silence, fault, reset, alert and evacuate\u003c\/li\u003e\n\u003cli\u003ePorts: RS232 printer and PC ports; RS485 serial expansion port for Syncro I\/O modules\u003c\/li\u003e\n\u003cli\u003eConfiguration: Loop Explorer PC utility (S187 standard or X187LS economy download lead)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784783442293,"sku":"MH80162M2","price":984.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroasm-1_3.jpg?v=1771967730"},{"product_id":"global-fire-gekko-2-loop-fire-control-panel-gekko-2","title":"Global Fire GEKKO 2 Loop Fire Control Panel (GEKKO-2)","description":"\u003cp\u003eThe Global Fire Equipment GEKKO is an analogue addressable fire alarm control panel certified to EN 54-2 and EN 54-4, and the successor to the GFE JUNIOR V4. This version is fitted for 2 loops. It is housed in an ABS enclosure whose cover is closed and fixed with just two screws.\u003c\/p\u003e\u003cp\u003eThe panel has room for two 12 V 7 Ah sealed lead-acid batteries, which GFE states give 24 hours of standby for the panel and its low-current devices. It works with GFE and ZEOS addressable loop devices, and can be networked with other GFE Chameleon panels such as the G-One, OCTO+ and NODE+.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAddressable panel expandable from 1 to 4 loops\u003c\/li\u003e\n\u003cli\u003eUp to 250 devices per loop (125 address limit)\u003c\/li\u003e\n\u003cli\u003eUp to 96 ultra-low-current addressable VULCAN 2 and\/or VALKYRIE sounders; 32 individually programmable sounder addresses per loop\u003c\/li\u003e\n\u003cli\u003eChameleon peer-to-peer network protocol for up to 32 panels, and networked systems of up to 128 loops\u003c\/li\u003e\n\u003cli\u003eRepeater connection via RS422, fibre optic or TCP\/IP\u003c\/li\u003e\n\u003cli\u003eFull self-addressing device support\u003c\/li\u003e\n\u003cli\u003eBuilt-in fire and fault relays and 2 individually programmable conventional alarm outputs\u003c\/li\u003e\n\u003cli\u003e384 fully programmable zones; 512 sounder groups and input\/output groups\u003c\/li\u003e\n\u003cli\u003eRemote access with ODYSSEY graphics software and BMS integration via Modbus\u003c\/li\u003e\n\u003cli\u003eCause-and-effect and site configuration loaded with CHAMELEON CONNECTOR software\u003c\/li\u003e\n\u003cli\u003eSupport for non-European languages\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLoops: 2 (range expandable from 1 to 4)\u003c\/li\u003e\n\u003cli\u003eMains supply: 90 V to 253 V, 50 Hz, 65 W\u003c\/li\u003e\n\u003cli\u003ePrimary DC supply: 28.5 V DC at 2.4 A max.\u003c\/li\u003e\n\u003cli\u003eSecondary supply: 21.6 V min. to 27.2 V DC max.; battery charger 27.5 V DC\u003c\/li\u003e\n\u003cli\u003eLoop output voltage: 28.5 V DC; conventional sounder output voltage: 28 V DC\u003c\/li\u003e\n\u003cli\u003eInternal batteries: standard box 2 x 12 V 7 Ah; larger box available for bigger batteries\u003c\/li\u003e\n\u003cli\u003eQuiescent current (no devices): 60 mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary power output: 2 x 24 V DC 300 mA \/ 1 x 24 V switched output\u003c\/li\u003e\n\u003cli\u003eLoop output current: 900 mA alarm peak \/ 165 mA quiescent per loop\u003c\/li\u003e\n\u003cli\u003eLoop topology: Class A (loop) or Class B (radial)\u003c\/li\u003e\n\u003cli\u003eLoop\/sounder cable: fire resistant 2 x 1.5 mm² (max. 1200 m) or 2 x 2.5 mm² (max. 2000 m)\u003c\/li\u003e\n\u003cli\u003eConventional sounder circuits: 500 mA max.\u003c\/li\u003e\n\u003cli\u003eRelays: 2 x fire and 1 x fault, each rated 2 A at 30 V DC \/ 0.5 A at 120 V AC \/ 0.25 A at 240 V AC resistive\u003c\/li\u003e\n\u003cli\u003eDisplay: high-contrast blue backlit graphical LCD, 240 x 64 pixels\u003c\/li\u003e\n\u003cli\u003eCommunication: 2 x configurable ports; USB type B for software\u003c\/li\u003e\n\u003cli\u003eBMS outputs: ODYSSEY software, TCP\/IP WEB remote monitoring, Modbus RTU, ESPA 4.4.4\u003c\/li\u003e\n\u003cli\u003eEvent log: 10,000 events\u003c\/li\u003e\n\u003cli\u003eOperating\/storage temperature: -10°C to +50°C; humidity 85% RH non-condensing\u003c\/li\u003e\n\u003cli\u003eIngress protection \/ material: IP30 \/ ABS\u003c\/li\u003e\n\u003cli\u003eDimensions: standard box 273 (W) x 403 (H) x 106 (D) mm; large box 273 x 403 x 142 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 1.6 kg (without batteries)\u003c\/li\u003e\n\u003cli\u003eCertification: EN 54-2 and EN 54-4 (1328-CPR-0737)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Global Fire Equipment","offers":[{"title":"Default Title","offer_id":56784962322805,"sku":"GEKKO-2","price":604.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/gekko-1_1.jpg?v=1771972155"},{"product_id":"global-fire-gekko-0-loop-fire-control-panel-gekko-0","title":"Global Fire GEKKO 0 Loop Fire Control Panel (GEKKO-0)","description":"\u003cp\u003eThe Global Fire Equipment GEKKO is an analogue addressable fire alarm control panel certified to EN 54-2 and EN 54-4, and the successor to the GFE JUNIOR V4. This listing (GEKKO-0) is the GEKKO panel with no loops fitted; the GEKKO platform is expandable from 1 to 4 loops. It is housed in an ABS enclosure whose cover is closed and fixed with just two screws.\u003c\/p\u003e\u003cp\u003eThe panel has room for two 12 V 7 Ah sealed lead-acid batteries, which GFE states give 24 hours of standby for the panel and its low-current devices. It works with GFE and ZEOS addressable loop devices, and can be networked with other GFE Chameleon panels such as the G-One, OCTO+ and NODE+.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAddressable panel expandable from 1 to 4 loops\u003c\/li\u003e\n\u003cli\u003eUp to 250 devices per loop (125 address limit)\u003c\/li\u003e\n\u003cli\u003eUp to 96 ultra-low-current addressable VULCAN 2 and\/or VALKYRIE sounders; 32 individually programmable sounder addresses per loop\u003c\/li\u003e\n\u003cli\u003eChameleon peer-to-peer network protocol for up to 32 panels, and networked systems of up to 128 loops\u003c\/li\u003e\n\u003cli\u003eRepeater connection via RS422, fibre optic or TCP\/IP\u003c\/li\u003e\n\u003cli\u003eFull self-addressing device support\u003c\/li\u003e\n\u003cli\u003eBuilt-in fire and fault relays and 2 individually programmable conventional alarm outputs\u003c\/li\u003e\n\u003cli\u003e384 fully programmable zones; 512 sounder groups and input\/output groups\u003c\/li\u003e\n\u003cli\u003eRemote access with ODYSSEY graphics software and BMS integration via Modbus\u003c\/li\u003e\n\u003cli\u003eCause-and-effect and site configuration loaded with CHAMELEON CONNECTOR software\u003c\/li\u003e\n\u003cli\u003eSupport for non-European languages\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLoops: none fitted as listed (range expandable from 1 to 4)\u003c\/li\u003e\n\u003cli\u003eMains supply: 90 V to 253 V, 50 Hz, 65 W\u003c\/li\u003e\n\u003cli\u003ePrimary DC supply: 28.5 V DC at 2.4 A max.\u003c\/li\u003e\n\u003cli\u003eSecondary supply: 21.6 V min. to 27.2 V DC max.; battery charger 27.5 V DC\u003c\/li\u003e\n\u003cli\u003eLoop output voltage: 28.5 V DC; conventional sounder output voltage: 28 V DC\u003c\/li\u003e\n\u003cli\u003eInternal batteries: standard box 2 x 12 V 7 Ah; larger box available for bigger batteries\u003c\/li\u003e\n\u003cli\u003eQuiescent current (no devices): 60 mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary power output: 2 x 24 V DC 300 mA \/ 1 x 24 V switched output\u003c\/li\u003e\n\u003cli\u003eLoop output current: 900 mA alarm peak \/ 165 mA quiescent per loop\u003c\/li\u003e\n\u003cli\u003eLoop topology: Class A (loop) or Class B (radial)\u003c\/li\u003e\n\u003cli\u003eLoop\/sounder cable: fire resistant 2 x 1.5 mm² (max. 1200 m) or 2 x 2.5 mm² (max. 2000 m)\u003c\/li\u003e\n\u003cli\u003eConventional sounder circuits: 500 mA max.\u003c\/li\u003e\n\u003cli\u003eRelays: 2 x fire and 1 x fault, each rated 2 A at 30 V DC \/ 0.5 A at 120 V AC \/ 0.25 A at 240 V AC resistive\u003c\/li\u003e\n\u003cli\u003eDisplay: high-contrast blue backlit graphical LCD, 240 x 64 pixels\u003c\/li\u003e\n\u003cli\u003eCommunication: 2 x configurable ports; USB type B for software\u003c\/li\u003e\n\u003cli\u003eBMS outputs: ODYSSEY software, TCP\/IP WEB remote monitoring, Modbus RTU, ESPA 4.4.4\u003c\/li\u003e\n\u003cli\u003eEvent log: 10,000 events\u003c\/li\u003e\n\u003cli\u003eOperating\/storage temperature: -10°C to +50°C; humidity 85% RH non-condensing\u003c\/li\u003e\n\u003cli\u003eIngress protection \/ material: IP30 \/ ABS\u003c\/li\u003e\n\u003cli\u003eDimensions: standard box 273 (W) x 403 (H) x 106 (D) mm; large box 273 x 403 x 142 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 1.6 kg (without batteries)\u003c\/li\u003e\n\u003cli\u003eCertification: EN 54-2 and EN 54-4 (1328-CPR-0737)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Global Fire Equipment","offers":[{"title":"Default Title","offer_id":56784980574581,"sku":"GEKKO-0","price":350.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/gekko-1.jpg?v=1771972515"},{"product_id":"global-fire-g-one-1-loop-fire-control-panel-non-expandable-g-1","title":"Global Fire G-ONE 1 Loop Fire Control Panel - Non Expandable (G-1)","description":"\u003cp\u003eThe Global Fire Equipment G-One is a single-loop analogue addressable fire alarm control panel. It is fixed at one loop and cannot be expanded. It is CPR certified to EN 54-2 and EN 54-4 and suits single-loop sites such as offices, restaurants, shops and schools.\u003c\/p\u003e\u003cp\u003eThe panel works with the ZEOS, GFE and Apollo digital analogue addressable protocols and with all GFE addressable ancillary modules. Its Chameleon peer-to-peer networking lets it join up to 32 GFE panels.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e900 mA single-loop addressable panel, 250 devices per loop (125 address limit)\u003c\/li\u003e\n\u003cli\u003eNetwork up to 32 G-One, GEKKO, OCTO+ and NODE+ panels; repeaters via RS422, fibre optic or TCP\/IP\u003c\/li\u003e\n\u003cli\u003eCompatible with ZEOS, GFE and Apollo digital analogue addressable protocols\u003c\/li\u003e\n\u003cli\u003eUp to 95 VULCAN 2 addressable ultra-low-current base sounders per loop (32 address limit)\u003c\/li\u003e\n\u003cli\u003eFull self-addressing device support and automatic self-learn facility\u003c\/li\u003e\n\u003cli\u003e384 programmable network zones, 512 alarm (sounder) groups and 512 I\/O groups; 16 integrated programmable fire zone LEDs\u003c\/li\u003e\n\u003cli\u003e2 fire relays (change-over), 1 fault relay (NC) and 2 programmable conventional alarm outputs\u003c\/li\u003e\n\u003cli\u003eSMS and email notification via the TCP IP-WEB interface\u003c\/li\u003e\n\u003cli\u003eProgramming via integrated keypad or USB loader PC software; multiple menu languages\u003c\/li\u003e\n\u003cli\u003eSurface or recessed mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMains supply: 90 V AC to 230 V AC\u003c\/li\u003e\n\u003cli\u003ePrimary DC supply: 28.5 V DC at 2.4 A max.\u003c\/li\u003e\n\u003cli\u003eSecondary supply: 21.6 V min. to 27.2 V DC max.; battery charger 27.5 V DC\u003c\/li\u003e\n\u003cli\u003eBatteries: standard box 2 x 12 V 7 Ah; deep box 2 x 12 V 12 Ah\u003c\/li\u003e\n\u003cli\u003eQuiescent current (no devices): 52 mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary power output: 2 x 24 V DC 300 mA \/ 1 x 24 V switched output\u003c\/li\u003e\n\u003cli\u003eLoop output current: 900 mA alarm peak \/ 165 mA quiescent\u003c\/li\u003e\n\u003cli\u003eLoop topology: Class A (loop) or Class B (radial)\u003c\/li\u003e\n\u003cli\u003eLoop cable: fire resistant 2 x 1.5 mm² (max. 1200 m) or 2 x 2.5 mm² (max. 2000 m)\u003c\/li\u003e\n\u003cli\u003eConventional sounder circuits: 500 mA for circuits A + B\u003c\/li\u003e\n\u003cli\u003eRelays: rated 2 A at 30 V DC \/ 0.5 A at 120 V AC \/ 0.25 A at 240 V AC resistive\u003c\/li\u003e\n\u003cli\u003eDisplay: high-contrast blue backlit graphical LCD, 240 x 64 pixels\u003c\/li\u003e\n\u003cli\u003eBMS outputs: ODYSSEY, TCP IP-WEB, Modbus RTU, ESPA 4.4.4; USB type B software connection\u003c\/li\u003e\n\u003cli\u003eEvent log: 10,000 events\u003c\/li\u003e\n\u003cli\u003eOperating\/storage temperature: -10°C to +55°C; humidity max. 85% RH non-condensing\u003c\/li\u003e\n\u003cli\u003eIngress protection \/ material: IP30 \/ ABS\u003c\/li\u003e\n\u003cli\u003eDimensions: standard box 273 (L) x 404 (H) x 107 (W) mm; deep box 273 x 404 x 142 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 1.6 kg (without batteries)\u003c\/li\u003e\n\u003cli\u003eCertification: EN 54-2 and EN 54-4 (1328-CPR-0811)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Global Fire Equipment","offers":[{"title":"Default Title","offer_id":56784980803957,"sku":"G-1","price":364.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/g-one-1.jpg?v=1771972517"},{"product_id":"global-fire-g-one-1-loop-fire-control-panel-non-expandable-black-g-1blk","title":"Global Fire G-ONE 1 Loop Fire Control Panel - Non Expandable (Black) (G-1BLK)","description":"\u003cp\u003eThe Global Fire Equipment G-One is a single-loop analogue addressable fire alarm control panel. It is fixed at one loop and cannot be expanded. This listing is the dark (black) finish version, G-1BLK. It is CPR certified to EN 54-2 and EN 54-4 and suits single-loop sites such as offices, restaurants, shops and schools.\u003c\/p\u003e\u003cp\u003eThe panel works with the ZEOS, GFE and Apollo digital analogue addressable protocols and with all GFE addressable ancillary modules. Its Chameleon peer-to-peer networking lets it join up to 32 GFE panels.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e900 mA single-loop addressable panel, 250 devices per loop (125 address limit)\u003c\/li\u003e\n\u003cli\u003eNetwork up to 32 G-One, GEKKO, OCTO+ and NODE+ panels; repeaters via RS422, fibre optic or TCP\/IP\u003c\/li\u003e\n\u003cli\u003eCompatible with ZEOS, GFE and Apollo digital analogue addressable protocols\u003c\/li\u003e\n\u003cli\u003eUp to 95 VULCAN 2 addressable ultra-low-current base sounders per loop (32 address limit)\u003c\/li\u003e\n\u003cli\u003eFull self-addressing device support and automatic self-learn facility\u003c\/li\u003e\n\u003cli\u003e384 programmable network zones, 512 alarm (sounder) groups and 512 I\/O groups; 16 integrated programmable fire zone LEDs\u003c\/li\u003e\n\u003cli\u003e2 fire relays (change-over), 1 fault relay (NC) and 2 programmable conventional alarm outputs\u003c\/li\u003e\n\u003cli\u003eSMS and email notification via the TCP IP-WEB interface\u003c\/li\u003e\n\u003cli\u003eProgramming via integrated keypad or USB loader PC software; multiple menu languages\u003c\/li\u003e\n\u003cli\u003eSurface or recessed mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMains supply: 90 V AC to 230 V AC\u003c\/li\u003e\n\u003cli\u003ePrimary DC supply: 28.5 V DC at 2.4 A max.\u003c\/li\u003e\n\u003cli\u003eSecondary supply: 21.6 V min. to 27.2 V DC max.; battery charger 27.5 V DC\u003c\/li\u003e\n\u003cli\u003eBatteries: standard box 2 x 12 V 7 Ah; deep box 2 x 12 V 12 Ah\u003c\/li\u003e\n\u003cli\u003eQuiescent current (no devices): 52 mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary power output: 2 x 24 V DC 300 mA \/ 1 x 24 V switched output\u003c\/li\u003e\n\u003cli\u003eLoop output current: 900 mA alarm peak \/ 165 mA quiescent\u003c\/li\u003e\n\u003cli\u003eLoop topology: Class A (loop) or Class B (radial)\u003c\/li\u003e\n\u003cli\u003eLoop cable: fire resistant 2 x 1.5 mm² (max. 1200 m) or 2 x 2.5 mm² (max. 2000 m)\u003c\/li\u003e\n\u003cli\u003eConventional sounder circuits: 500 mA for circuits A + B\u003c\/li\u003e\n\u003cli\u003eRelays: rated 2 A at 30 V DC \/ 0.5 A at 120 V AC \/ 0.25 A at 240 V AC resistive\u003c\/li\u003e\n\u003cli\u003eDisplay: high-contrast blue backlit graphical LCD, 240 x 64 pixels\u003c\/li\u003e\n\u003cli\u003eBMS outputs: ODYSSEY, TCP IP-WEB, Modbus RTU, ESPA 4.4.4; USB type B software connection\u003c\/li\u003e\n\u003cli\u003eEvent log: 10,000 events\u003c\/li\u003e\n\u003cli\u003eOperating\/storage temperature: -10°C to +55°C; humidity max. 85% RH non-condensing\u003c\/li\u003e\n\u003cli\u003eIngress protection \/ material: IP30 \/ ABS\u003c\/li\u003e\n\u003cli\u003eDimensions: standard box 273 (L) x 404 (H) x 107 (W) mm; deep box 273 x 404 x 142 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 1.6 kg (without batteries)\u003c\/li\u003e\n\u003cli\u003eCertification: EN 54-2 and EN 54-4 (1328-CPR-0811)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Global Fire Equipment","offers":[{"title":"Default Title","offer_id":56784980967797,"sku":"G-1(BLK)","price":364.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/g-oneblk-1.jpg?v=1771972519"},{"product_id":"c-tec-xfp-1-loop-16-zone-addressable-fire-panel-hochiki-esp-protocol-xfp501e-h","title":"C-TEC XFP 1 Loop 16 Zone Addressable Fire Panel (Hochiki ESP Protocol) (XFP501E\/H)","description":"\u003cp\u003eThe C-TEC XFP501E\/H is a single-loop, 16 zone addressable fire alarm panel for Hochiki ESP protocol devices. LPCB certified to EN 54-2 and 4, it is one of Europe's best-selling entry-level addressable panels, suitable for small stand-alone sites or larger applications thanks to its ability to network with up to 8 XFP main panels. It is also fully compatible with C-TEC's Hush Button fire alarm solution.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHochiki ESP protocol, up to 126 addressable devices on the loop\u003c\/li\u003e\n\u003cli\u003eTwo independently programmable conventional sounder circuits and two programmable inputs\u003c\/li\u003e\n\u003cli\u003eFault relay plus three programmable volt-free changeover relays\u003c\/li\u003e\n\u003cli\u003eZone dependency\/coincidence, day\/night, investigation delay and phased evacuation functions\u003c\/li\u003e\n\u003cli\u003eShort-circuit protected loop driver supporting up to 40 loop-powered 10mA sounders\u003c\/li\u003e\n\u003cli\u003eIntegral EN 54-4\/A2 switch mode power supply\u003c\/li\u003e\n\u003cli\u003eAdjustable contamination levels, earth fault monitoring and an alarm counter\u003c\/li\u003e\n\u003cli\u003eCombined keypad\/keyswitch entry to access levels 2 and 3\u003c\/li\u003e\n\u003cli\u003e999 event log\u003c\/li\u003e\n\u003cli\u003eWindows upload\/download PC software (XFP507, sold separately)\u003c\/li\u003e\n\u003cli\u003eNetworks up to 8 XFP main panels, or up to 8 XFP repeaters on a non-networked main panel (optional network card)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e XFP501E\/H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Hochiki ESP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop output current:\u003c\/strong\u003e 500mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. loop length:\u003c\/strong\u003e 1km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per loop:\u003c\/strong\u003e 126\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 (max. 400mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e 3 programmable + 1 fault, 1A 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50\/60Hz, 350mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal output current:\u003c\/strong\u003e 1.4A at 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah VRLA (in series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 2 line x 40 character backlit LCD, 16 zonal LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 380 x 235 x 96mm (W x H x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Plastic lid and base, RAL 7035 textured, IP30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.8kg without batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating conditions:\u003c\/strong\u003e -5°C to +40°C, max. 95% RH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"C-TEC","offers":[{"title":"Default Title","offer_id":56784981033333,"sku":"XFP501E\/H","price":394.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/9742_2nd.jpg?v=1771972520"},{"product_id":"haes-esprit-1-2-loop-addressable-fire-panel-argus-protocol-esa-1001","title":"HAES Esprit 1-2 Loop Addressable Fire Panel (Argus Protocol) (ESA-1001)","description":"\u003cp\u003eThe HAES Esprit ESA-1001 is an analogue addressable fire alarm control panel for the Argus protocol, supplied with one loop and extendable to 2 loops. With up to 240 devices per loop, its compact styling and programming power suit small and medium sites.\u003c\/p\u003e\u003cp\u003eA large graphical display gives an easy-to-navigate menu system for set-up and maintenance, and the panel has 18 zonal LEDs and a 1.2A integral power supply.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne to 2 loops, up to 240 devices per loop\u003c\/li\u003e\n\u003cli\u003eLarge backlit graphical display with easy-to-navigate menus\u003c\/li\u003e\n\u003cli\u003e2 programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003e255 date and time stamped event log entries\u003c\/li\u003e\n\u003cli\u003eAuto learn function and loop fault diagnostics\u003c\/li\u003e\n\u003cli\u003eFalse alarm management and delays to outputs\u003c\/li\u003e\n\u003cli\u003e64 programmable groups\u003c\/li\u003e\n\u003cli\u003e18 zonal LEDs; 1.2A integral PSU\u003c\/li\u003e\n\u003cli\u003eProgrammable company logo\u003c\/li\u003e\n\u003cli\u003eApproved to EN54-2 and EN54-4\u003c\/li\u003e\n\u003cli\u003eRobust metal enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 350mm W x 300mm H x 80mm D; lid 357mm W x 310mm H x 25mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: universal switch mode PSU, 1.2A\u003c\/li\u003e\n\u003cli\u003eBattery capacity: up to 7Ah 24V\u003c\/li\u003e\n\u003cli\u003eCharger current: 700mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 400mA (21-28V DC)\u003c\/li\u003e\n\u003cli\u003eLoop: Argus protocol, up to 2 loops, 500mA maximum per loop\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x 400mA, 21-28V DC\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: class change, pulsing\u003c\/li\u003e\n\u003cli\u003eEvent log: 255 events, time and date stamped\u003c\/li\u003e\n\u003cli\u003eEarth fault monitoring: yes\u003c\/li\u003e\n\u003cli\u003eDisplay: 240 x 64 backlit graphical LCD\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784981295477,"sku":"ESA-1001","price":518.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/esa-1006-1_1.jpg?v=1771972534"},{"product_id":"haes-esprit-1-2-loop-addressable-fire-panel-apollo-protocol-esa-1007","title":"HAES Esprit 1-2 Loop Addressable Fire Panel (Apollo Protocol) (ESA-1006)","description":"\u003cp\u003eThe HAES Esprit ESA-1006 is an analogue addressable fire alarm control panel for the Apollo protocol, supplied with one loop and extendable to 2 loops. With up to 240 devices per loop, its compact styling and programming power suit small and medium sites.\u003c\/p\u003e\u003cp\u003eIt supports the full range of Apollo protocol devices, including Apollo wireless and Soteria products (up to 240 addresses per loop when using Soteria devices), and is supplied with a 3.4A internal switch mode power supply.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne to 2 loops, up to 240 devices per loop\u003c\/li\u003e\n\u003cli\u003eLarge backlit graphical display with easy-to-navigate menus\u003c\/li\u003e\n\u003cli\u003e2 programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003e255 date and time stamped event log entries\u003c\/li\u003e\n\u003cli\u003eAuto learn function and loop fault diagnostics\u003c\/li\u003e\n\u003cli\u003eFalse alarm management and delays to outputs\u003c\/li\u003e\n\u003cli\u003e64 programmable groups\u003c\/li\u003e\n\u003cli\u003e18 zonal LEDs; 3.4A integral PSU\u003c\/li\u003e\n\u003cli\u003eProgrammable company logo\u003c\/li\u003e\n\u003cli\u003eApproved to EN54-2 and EN54-4\u003c\/li\u003e\n\u003cli\u003eRobust metal enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 350mm W x 300mm H x 80mm D; lid 357mm W x 310mm H x 25mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: universal switch mode PSU, 230V AC ±10% 50Hz, 1.2A input current\u003c\/li\u003e\n\u003cli\u003eBattery capacity: up to 7Ah 24V, fire retardant\u003c\/li\u003e\n\u003cli\u003eCharger current: 700mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 400mA, 28V\u003c\/li\u003e\n\u003cli\u003eLoop: Apollo protocol, up to 2 loops, 500mA per loop\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x 400mA, 28V DC\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: class change, pulsing\u003c\/li\u003e\n\u003cli\u003eEvent log: 255 events, time and date stamped\u003c\/li\u003e\n\u003cli\u003eEarth fault monitoring: yes\u003c\/li\u003e\n\u003cli\u003eDisplay: 240 x 64 backlit graphical LCD\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784981328245,"sku":"ESA-1006","price":489.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/esa-1006-1_78e56679-187a-426b-96dc-87d77b10f010.jpg?v=1771972537"},{"product_id":"nittan-evolution-1-single-loop-touch-screen-addressable-fire-alarm-panel-evolution1","title":"Nittan Evolution 1 Single Loop Touch-Screen Addressable Fire Alarm Panel (evolution1)","description":"\u003cp\u003eThe Nittan evolution 1 (part no. F12-83101) is a single-loop analogue addressable fire alarm control panel with a 4.3-inch colour touch screen. It is fully compatible with the Nittan Evolution range of detection and alarm devices and is certified to EN 54-2 and EN 54-4.\u003c\/p\u003e\u003cp\u003eCause and effect can be set up on the panel itself or with the PC configuration tool and downloaded. A built-in network card lets you link up to 16 panels without extra hardware. The ABS enclosure has a fully removable front cover for easier cabling and termination.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4.3-inch colour touch screen with an intuitive menu\u003c\/li\u003e\n\u003cli\u003eUp to 254 devices on the loop and 254 zones\u003c\/li\u003e\n\u003cli\u003eFull cause-and-effect programming at the panel or with the PC configuration tool\u003c\/li\u003e\n\u003cli\u003eBuilt-in network card: network up to 16 panels\u003c\/li\u003e\n\u003cli\u003e2 x configurable RS485 ports\u003c\/li\u003e\n\u003cli\u003eUp to 8 password-protected users\u003c\/li\u003e\n\u003cli\u003eSwitch-mode power supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMains supply: 230 V AC (+10% \/ -15%), 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOperating current: 1.0 A max.\u003c\/li\u003e\n\u003cli\u003eSystem voltage: 24 V DC nominal\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA\u003c\/li\u003e\n\u003cli\u003eSounder outputs: 2 x 200 mA at 24 V DC\u003c\/li\u003e\n\u003cli\u003eFault relay: 1 x volt-free, SELV, 1 A max.\u003c\/li\u003e\n\u003cli\u003eCharger voltage: 27.6 V DC\u003c\/li\u003e\n\u003cli\u003eBattery cut-off: 0.9 ohm\u003c\/li\u003e\n\u003cli\u003eBatteries: 2 x 7.0 Ah 12 V DC sealed lead acid max.\u003c\/li\u003e\n\u003cli\u003eEnclosure: W 370 x H 311 x D 113 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 2.7 kg without batteries (7.35 kg with batteries)\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-2:1997 + A1:2006; EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNote: Nittan advises that panels with firmware 22.0.0 or newer cannot be networked with panels running firmware 21.09.05.20 or older.\u003c\/p\u003e","brand":"Nittan","offers":[{"title":"Default Title","offer_id":56784981426549,"sku":"evolution1","price":495.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/10677_2nd.jpg?v=1771972541"},{"product_id":"c-tec-xfp-1-loop-32-zone-addressable-fire-panel-xp95-discovery-protocol-xfp501-x","title":"C-TEC XFP 1 Loop 32 Zone Addressable Fire Panel (XP95\/Discovery Protocol) (XFP501\/X)","description":"\u003cp\u003eThe C-TEC XFP501\/X is a single loop, 32 zone analogue addressable fire alarm panel for Apollo XP95 and Discovery protocol devices. It is LPCB certified to EN54-2 and EN54-4, comes in a durable metal enclosure and suits small stand-alone sites as well as larger buildings, as up to eight XFP master panels can be networked. It is also compatible with C-TEC's Hush Button solution and its EN54 certified addressable sounders and VADs.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThird-party certified to EN54-2\/4 by the LPCB\u003c\/li\u003e\n\u003cli\u003eCompatible with Apollo XP95\/Discovery protocol\u003c\/li\u003e\n\u003cli\u003eCombined keypad\/keyswitch entry to Access Levels 2 and 3\u003c\/li\u003e\n\u003cli\u003eTwo independently programmable conventional sounder circuits\u003c\/li\u003e\n\u003cli\u003eTwo programmable inputs\u003c\/li\u003e\n\u003cli\u003eFault output relay plus three programmable volt-free changeover relays\u003c\/li\u003e\n\u003cli\u003eZone dependency\/coincidence functions, day\/night mode and investigation delay\u003c\/li\u003e\n\u003cli\u003ePhased evacuation facility and alarm counter\u003c\/li\u003e\n\u003cli\u003eShort circuit protected loop driver supporting up to 40 loop-powered 10mA sounders per loop\u003c\/li\u003e\n\u003cli\u003eIntegral EN54-4\/A2 switch mode power supply\u003c\/li\u003e\n\u003cli\u003eAdjustable contamination levels and earth fault monitoring\u003c\/li\u003e\n\u003cli\u003e999 event log\u003c\/li\u003e\n\u003cli\u003eWindows-based upload\/download PC program\u003c\/li\u003e\n\u003cli\u003eUp to 8 XFP main panels on a two-wire RS485 network, or up to 8 XFP repeaters on a non-networked main panel\u003c\/li\u003e\n\u003cli\u003eOptional flush-mounting bezel and glazed stainless steel enclosure available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eApprovals: EN54-2 \u0026amp; EN54-4 (LPCB)\u003c\/li\u003e\n\u003cli\u003eProtocol: Apollo XP95\/Discovery\u003c\/li\u003e\n\u003cli\u003eLoops: 1; max. 126 addressable devices per loop\u003c\/li\u003e\n\u003cli\u003eZones: 32 (zonal LEDs)\u003c\/li\u003e\n\u003cli\u003eMax. loop output current: 500mA (25V min., 34V max.)\u003c\/li\u003e\n\u003cli\u003eMax. loop length: 1km\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V 50\/60Hz, 680mA max.\u003c\/li\u003e\n\u003cli\u003eInternal power supply: 27V DC nominal; total output current limited to 3A\u003c\/li\u003e\n\u003cli\u003eQuiescent current: 80mA (loop unloaded)\u003c\/li\u003e\n\u003cli\u003eBatteries: 2 x 12V 7Ah VRLA in series\u003c\/li\u003e\n\u003cli\u003eConventional sounder circuits: 2 (max. 500m each), max. 400mA sounder output current\u003c\/li\u003e\n\u003cli\u003eEnd-of-line resistor: 6k8Ω\u003c\/li\u003e\n\u003cli\u003eRelays: 3 programmable plus 1 fault relay, volt-free single pole changeover, max. 1A at 30V DC\u003c\/li\u003e\n\u003cli\u003eAuxiliary 24V output: max. 100mA, resettable fuse\u003c\/li\u003e\n\u003cli\u003eInputs: 2 programmable (connect to 0V to trigger)\u003c\/li\u003e\n\u003cli\u003eDisplay: 2 line x 40 character backlit LCD\u003c\/li\u003e\n\u003cli\u003ePC connection: RS232 (upload\/download software kit XFP507)\u003c\/li\u003e\n\u003cli\u003eNetwork\/repeater connection: via optional AFP711 network card\u003c\/li\u003e\n\u003cli\u003eDimensions: base 410mm (W) x 250mm (H) x 80mm (D); lid 439mm (W) x 274mm (H) x 7mm (D)\u003c\/li\u003e\n\u003cli\u003eConstruction: metal, IP30\u003c\/li\u003e\n\u003cli\u003eWeight: 4.5kg (without batteries)\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C, max. 95% relative humidity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"C-TEC","offers":[{"title":"Default Title","offer_id":56784981524853,"sku":"XFP501\/X","price":534.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/9728_2nd.jpg?v=1771972546"}],"url":"https:\/\/jemsystems.co.uk\/collections\/addressable-fire-alarm-panels.oembed","provider":"JEM Systems UK","version":"1.0","type":"link"}