{"title":"Conventional Fire Alarm Panels","description":"\u003cp\u003eConventional fire alarm panels divide a building into detection zones, with each zone wired as its own circuit. When a detector or call point operates, the panel shows which zone is in alarm, which makes them a practical choice for shops, small offices, schools and other single-site premises where the layout is straightforward.\u003c\/p\u003e\u003cp\u003eThis range covers conventional control panels from 2 up to 32 zones, including 2-wire and AlarmSense models from brands such as Advanced, C-TEC, Kentec, HAES, Zeta, Fike and FireClass. Zone counts are listed in each product title, so you can match the panel to the zones on your design and leave some spare capacity for future changes.\u003c\/p\u003e\u003ch2\u003eChoosing a conventional panel\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e BS 5839-1 sets limits on the area and search distance of a detection zone, so count zones from the design rather than from the number of rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e 2-wire panels carry detectors and sounders on the same pair of cables, while 4-wire panels use separate sounder circuits. See our \u003ca href=\"\/collections\/two-wire-fire-alarm-panels\"\u003e2-wire fire alarm panels\u003c\/a\u003e for that variant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e check that detectors, sounders and call points are suitable for the panel you choose.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor larger or multi-storey buildings where you need to identify individual devices, see our \u003ca href=\"\/collections\/addressable-fire-alarm-panels\"\u003eaddressable fire alarm panels\u003c\/a\u003e. The full range is on the \u003ca href=\"\/collections\/fire-alarm-panels\"\u003efire alarm panels\u003c\/a\u003e page, and you can browse by manufacturer through \u003ca href=\"\/collections\/c-tec\"\u003eC-TEC\u003c\/a\u003e and \u003ca href=\"\/collections\/kentec\"\u003eKentec\u003c\/a\u003e. Panels should be designed, installed and commissioned by a competent person in line with BS 5839-1.\u003c\/p\u003e","products":[{"product_id":"fireclass-508-032-730-essential-2-zone-panel","title":"FireClass 508.032.730 Essential 2 Zone Panel","description":"\u003ch2\u003eFireClass 508.032.730 Essential 2 Zone Panel\u003c\/h2\u003e\n\u003cp\u003eThe Fireclass Essential Panel range is an EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants.\u003c\/p\u003e\n\u003cp\u003eThe panels can support up to 128 devices with a maximum of 32 devices on each zone.\u003c\/p\u003e\n\u003cp\u003eThe panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch3\u003eThe panel UI has the following features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e18 LEDs on the 2 Zone Panel and 22 LEDs on the 4 Zone Panel\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOne piezo buzzer for audible indication\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEight push buttons for user inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePlease note: For full details on all the supported devices, refer to the EN 54-13 certificate.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149567443317,"sku":"508.032.730","price":122.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/508-032-730.jpg?v=1769635953"},{"product_id":"fireclass-508-032-731-essential-4-zone-panel","title":"FireClass 508.032.731 Essential 4 Zone Panel","description":"\u003ch2\u003eFireClass 508.032.731 Essential 4 Zone Panel\u003c\/h2\u003e\n\u003cp\u003eThe Fireclass Essential Panel range is an EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants.\u003c\/p\u003e\n\u003cp\u003eThe panels can support up to 128 devices with a maximum of 32 devices on each zone.\u003c\/p\u003e\n\u003cp\u003eThe panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch3\u003eThe panel UI has the following features:\u003c\/h3\u003e\n\u003cp\u003e18 LEDs on the 2 Zone Panel and 22 LEDs on the 4 Zone Panel\u003cbr\u003eOne piezo buzzer for audible indication\u003cbr\u003eEight push buttons for user inputs\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModern and aesthetic design\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePlease note: For full details on all the supported devices, refer to the EN 54-13 certificate.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149567902069,"sku":"508.032.731","price":134.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/20241223_112214_c4a4ecad-4407-4997-a924-983ed0b28350.jpg?v=1782725646"},{"product_id":"advanced-qzxl-32-quickzone-xl-32-zone-panel","title":"Advanced QZXL-32 QuickZone XL 32 Zone panel","description":"\u003cp\u003eThe Advanced QZXL-32 QuickZone XL is a 32 zone conventional fire alarm control panel with an integral power supply and space for standby batteries. It is approved to EN 54-2 and EN 54-4 and works with a wide range of conventional fire detectors, including Apollo, Argus, Hochiki and Nittan.\u003c\/p\u003e\u003cp\u003eDependency modes A, B and C help reduce false alarms, and a one-man walk test simplifies maintenance.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32 conventional fire zones\u003c\/li\u003e\n\u003cli\u003eFour monitored sounder circuits with 500mA resettable fuses\u003c\/li\u003e\n\u003cli\u003eFire and fault volt-free changeover relays, plus programmable switched negative outputs for fire, fault, disablement and reset\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs\u003c\/li\u003e\n\u003cli\u003eFire alarm routing output\u003c\/li\u003e\n\u003cli\u003eThree dependency modes to manage false alarms\u003c\/li\u003e\n\u003cli\u003eOne-man walk test, with or without sounders\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003eKey switch or code entry for access level 2\u003c\/li\u003e\n\u003cli\u003eNetworks up to 8 control panels\u003c\/li\u003e\n\u003cli\u003eIntegral 5A switch mode PSU with space for two 18Ah batteries\u003c\/li\u003e\n\u003cli\u003eSpacious enclosure for easy installation and cabling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 32, conventional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indicators:\u003c\/strong\u003e 33 red (1 x fire, 32 zonal), 1 green (power), plus amber zonal, fault and system LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e Colour-coded Resound, Silence and Reset buttons, 1-4 numerical buttons and Enter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Via on-board buttons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 4 monitored (500mA resettable fuse)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 auxiliary clean changeover relays (1 fire, 1 fault), 3A max at 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 28V DC 400mA continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50Hz (+10% \/ -15%), 1.9A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 2 x 18Ah 12V SLA, internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e Limited to 2.0A (27.0V DC at 20°C, temperature compensated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking:\u003c\/strong\u003e Up to 8 control panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Lockable steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 41 x top, 35 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Back box 400 x 450 x 130mm; door 410 x 465 x 25mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2, EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332017533301,"sku":"QZXL-32","price":1667.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/8759_2nd.jpg?v=1771961068"},{"product_id":"advanced-qzxl-24-quickzone-xl-24-zone-panel","title":"Advanced QZXL-24 QuickZone XL 24 Zone panel","description":"\u003cp\u003eThe Advanced QZXL-24 is the 24-zone version of the QuickZone XL conventional fire alarm control panel, with an integral power supply and space for standby batteries. It suits conventional detection systems and supports an extensive range of conventional fire detectors, including Apollo, Argus, Hochiki and Nittan.\u003c\/p\u003e\u003cp\u003eFour monitored sounder circuits, fire and fault volt-free changeover relays, and programmable fire, fault, disablement and reset switched negative outputs are provided, along with class change and alert inputs. Dependency modes A, B and C help reduce false alarms, and the panel allows one-man walk testing.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e24 conventional fire zones\u003c\/li\u003e\n\u003cli\u003e3 dependency modes (A, B and C) to help manage false alarms\u003c\/li\u003e\n\u003cli\u003eOne-man walk test; test mode with or without sounders\u003c\/li\u003e\n\u003cli\u003eKey switch or code entry for Level 2 access\u003c\/li\u003e\n\u003cli\u003eIntegral 5A switch mode power supply\u003c\/li\u003e\n\u003cli\u003eSpace for two 18Ah batteries\u003c\/li\u003e\n\u003cli\u003eFour monitored sounder circuits with 500mA resettable fuses\u003c\/li\u003e\n\u003cli\u003eProgrammable relays and outputs, including fire alarm routing output\u003c\/li\u003e\n\u003cli\u003eClass change and alert programmable inputs\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003eNetwork up to 8 control panels\u003c\/li\u003e\n\u003cli\u003eSpacious enclosure for easy installation and cabling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire zones:\u003c\/strong\u003e 24 (conventional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e Colour-coded Resound, Silence and Reset buttons, 1-4 numerical buttons and Enter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 4 x monitored (500mA resettable fuse)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e 2 x auxiliary clean changeover, 3A at 30V DC max (1 x fire, 1 x fault)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50Hz (+10% \/ -15%), 1.9A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 28V DC 400mA (continuous load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable inputs:\u003c\/strong\u003e Class change and alert\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 2 x 18Ah internal 12V SLA (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e Limited to 2.0A (27.0V DC at 20°C, temperature compensated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking:\u003c\/strong\u003e Up to 8 control panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Lockable steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 41 x top, 35 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Back box 400 x 450 x 130mm; door 410 x 465 x 25mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332021727605,"sku":"QZXL-24","price":1344.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/8758_2nd.jpg?v=1771961064"},{"product_id":"advanced-qzxl-16-quickzone-xl-16-zone-panel","title":"Advanced QZXL-16 QuickZone XL 16 Zone panel","description":"\u003cp\u003eThe Advanced QZXL-16 QuickZone XL is a 16-zone conventional fire alarm control panel with an integral power supply and space for standby batteries, approved to EN 54-2 and EN 54-4. It works with a wide range of conventional fire detectors, including Apollo, Argus, Hochiki and Nittan.\u003c\/p\u003e\u003cp\u003eDependency modes A, B and C help reduce false alarms, and a one-man walk test simplifies maintenance.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 conventional fire zones\u003c\/li\u003e\n\u003cli\u003eFour monitored sounder circuits with 500mA resettable fuses\u003c\/li\u003e\n\u003cli\u003eFire and fault volt-free changeover relays, plus programmable switched negative outputs for fire, fault, disablement and reset\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs\u003c\/li\u003e\n\u003cli\u003eFire alarm routing output\u003c\/li\u003e\n\u003cli\u003eThree dependency modes to manage false alarms\u003c\/li\u003e\n\u003cli\u003eOne-man walk test, with or without sounders\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003eKey switch or code entry for access level 2\u003c\/li\u003e\n\u003cli\u003eNetworks up to 8 control panels\u003c\/li\u003e\n\u003cli\u003eIntegral 5A switch mode PSU with space for two 18Ah batteries\u003c\/li\u003e\n\u003cli\u003eSpacious enclosure for easy installation and cabling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 16, conventional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e Colour-coded Resound, Silence and Reset buttons, 1-4 numerical buttons and Enter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Via on-board buttons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 4 monitored (500mA resettable fuse)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 auxiliary clean changeover relays (1 fire, 1 fault), 3A max at 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 28V DC 400mA continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50Hz (+10% \/ -15%), 1.9A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 2 x 18Ah 12V SLA, internal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger:\u003c\/strong\u003e Limited to 2.0A (27.0V DC at 20°C, temperature compensated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking:\u003c\/strong\u003e Up to 8 control panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Lockable steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 41 x top, 35 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Back box 400 x 450 x 130mm; door 410 x 465 x 25mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2:1997 + A1:2006; EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332023923061,"sku":"QZXL-16","price":994.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/8757_2nd.jpg?v=1771961050"},{"product_id":"advanced-qzxl-12hs-quickzone-xl-12-zone-panel-high-spec","title":"Advanced QZXL-12HS QuickZone XL - 12 Zone panel (high spec)","description":"\u003cp\u003eThe Advanced QZXL-12HS is a QuickZone XL 12 zone conventional \/ twin wire (Sav-Wire) fire alarm control panel, fitted with one standard and one high specification zone card. It has an integral power supply and space for standby batteries.\u003c\/p\u003e\u003cp\u003eIt is approved to EN 54-2 and EN 54-4 and supports a wide range of conventional fire detectors, including Apollo, Argus, Hochiki and Nittan. The high specification card adds two monitored sounder outputs, programmable switched negative outputs and a programmable relay.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e12 conventional or twin wire zones (selectable by DIL switches)\u003c\/li\u003e\n\u003cli\u003eTwo monitored sounder circuits as standard, plus two more from the high specification card\u003c\/li\u003e\n\u003cli\u003eAlarm load of 2.4A shared across all sounder outputs\u003c\/li\u003e\n\u003cli\u003eFire and fault volt-free changeover relays, plus programmable relays and outputs\u003c\/li\u003e\n\u003cli\u003eClass change and alert programmable inputs\u003c\/li\u003e\n\u003cli\u003eDependency modes A, B and C\u003c\/li\u003e\n\u003cli\u003eTest mode, with or without sounders\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003eSupports up to 8 fully functional repeater panels\u003c\/li\u003e\n\u003cli\u003eKey switch or code entry for access level 2\u003c\/li\u003e\n\u003cli\u003eIntegral 3A switch mode PSU with space for 2 x 7.0Ah batteries\u003c\/li\u003e\n\u003cli\u003eOne-year warranty as standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 12 (1 x standard and 1 x high specification zone card)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indicators:\u003c\/strong\u003e 13 red (1 x fire, 12 x zonal), 1 green (power), 22 amber (12 x zonal, 10 fault and system)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e Colour-coded Resound, Silence and Reset buttons, 1-4 numerical buttons and Enter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 monitored (1A resettable fuse), further 2 via high specification card\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 auxiliary clean changeover relays (1 fire, 1 fault), 3A max at 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50Hz (+10% \/ -15%), 1.2A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 28V DC 400mA continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 2 x 7.0Ah 12V SLA, internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger current:\u003c\/strong\u003e 1.34A (27.0V DC at 20°C, temperature compensated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking:\u003c\/strong\u003e Fully functional repeater panels via plug-in communications PCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Lockable steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 20 x top, 8 x rear, 4 x base (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Back box 300 x 450 x 85mm; door 310 x 460 x 25mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2:1997 + A1:2006, EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332026478965,"sku":"QZXL-12HS","price":711.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/11581_2nd.jpg?v=1771961038"},{"product_id":"advanced-qzxl-8hs-quickzone-xl-8-zone-panel-high-spec","title":"Advanced QZXL-8HS QuickZone XL - 8 Zone panel (high spec)","description":"\u003cp\u003eThe Advanced QZXL-8HS QuickZone XL is an 8-zone conventional \/ Twin Wire (Sav-Wire) fire alarm control panel with integral power supply and space for standby batteries, approved to EN 54-2 and EN 54-4. It is supplied with the high specification zone card fitted, which adds two further monitored sounder circuits, programmable switched negative outputs and a programmable relay. The panel is easy to install and maintain and simple for the end user to operate.\u003c\/p\u003e\u003cp\u003eLevel 2 controls include Resound, Silence and Reset, plus disable and test modes; Level 3 allows sounder resound options, dependency settings, buzzer volume, the event log and panel-wide settings such as access codes and delays. It supports an extensive range of conventional fire detectors, including Apollo, Argus, Hochiki and Nittan; Twin Wire mode requires special 'Sav-Wire' detector bases and polarised 470 ohm call points.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 fire zones (high specification zone card fitted)\u003c\/li\u003e\n\u003cli\u003eTwo additional monitored sounder circuits, programmable switched negative outputs and one programmable relay from the high specification card\u003c\/li\u003e\n\u003cli\u003eConventional or Twin Wire (Sav-Wire) zone circuits, selectable by DIL switch\u003c\/li\u003e\n\u003cli\u003eTwo monitored sounder circuits as standard\u003c\/li\u003e\n\u003cli\u003eFire and fault volt-free changeover relays, plus fire and fault switched negative outputs\u003c\/li\u003e\n\u003cli\u003eClass change and alert programmable inputs\u003c\/li\u003e\n\u003cli\u003eDependency modes A, B and C\u003c\/li\u003e\n\u003cli\u003eTest mode, with or without sounders\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003eKey switch or code entry for activation of controls\u003c\/li\u003e\n\u003cli\u003eIntegral 3A switch mode PSU with space for up to 2 x 7.0Ah batteries\u003c\/li\u003e\n\u003cli\u003eCan support up to 8 fully functional repeater panels\u003c\/li\u003e\n\u003cli\u003eModular expansion zone cards available\u003c\/li\u003e\n\u003cli\u003eAlarm load of 2.4A shared across all sounder outputs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of fire zones:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZonal circuit configuration:\u003c\/strong\u003e Conventional or Twin Wire (selectable by DIL switches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e 3 colour-coded buttons (Resound, Silence and Reset), 1-4 numerical buttons and Enter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey switch input:\u003c\/strong\u003e Level 2 access enable key switch or code entry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board sounder circuits:\u003c\/strong\u003e 2 monitored (1A resettable fuse); a further two available with the high specification card\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 auxiliary clean changeover relays (1 Fire, 1 Fault), 3A max at 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50Hz (+10% \/ -15%), 1.2A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 28V DC 400mA continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable inputs:\u003c\/strong\u003e Class change and alert\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 2 x 7.0Ah 12V SLA, internal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger current:\u003c\/strong\u003e 1.34A (27.0V DC at 20°C, temperature compensated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking:\u003c\/strong\u003e Fully functional repeater panel via plug-in communications PCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Lockable steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 20 x top, 8 x rear, 4 x base (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Back box 300 x 450 x 85mm; door 310 x 460 x 25mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2:1997 + A1:2006; EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332026937717,"sku":"QZXL-8HS","price":566.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/8749_2nd.jpg?v=1771961035"},{"product_id":"advanced-qzxl-4-quickzone-xl-4-zone-panel","title":"Advanced QZXL-4 QuickZone XL - 4 Zone Panel","description":"\u003cp\u003eThe Advanced QZXL-4 QuickZone XL is a 4-zone conventional \/ Twin Wire (Sav-Wire) fire alarm control panel with integral power supply and space for standby batteries, approved to EN 54-2 and EN 54-4. It can be expanded up to 12 zones with modular expansion zone cards. The panel is easy to install and maintain and simple for the end user to operate.\u003c\/p\u003e\u003cp\u003eLevel 2 controls include Resound, Silence and Reset, plus disable and test modes; Level 3 allows sounder resound options, dependency settings, buzzer volume, the event log and panel-wide settings such as access codes and delays. It supports an extensive range of conventional fire detectors, including Apollo, Argus, Hochiki and Nittan; Twin Wire mode requires special 'Sav-Wire' detector bases and polarised 470 ohm call points.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 fire zones (expandable to 12)\u003c\/li\u003e\n\u003cli\u003eConventional or Twin Wire (Sav-Wire) zone circuits, selectable by DIL switch\u003c\/li\u003e\n\u003cli\u003eTwo monitored sounder circuits as standard\u003c\/li\u003e\n\u003cli\u003eFire and fault volt-free changeover relays, plus fire and fault switched negative outputs\u003c\/li\u003e\n\u003cli\u003eClass change and alert programmable inputs\u003c\/li\u003e\n\u003cli\u003eDependency modes A, B and C\u003c\/li\u003e\n\u003cli\u003eTest mode, with or without sounders\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003eKey switch or code entry for activation of controls\u003c\/li\u003e\n\u003cli\u003eIntegral 3A switch mode PSU with space for up to 2 x 7.0Ah batteries\u003c\/li\u003e\n\u003cli\u003eCan support up to 8 fully functional repeater panels\u003c\/li\u003e\n\u003cli\u003eModular expansion zone cards available\u003c\/li\u003e\n\u003cli\u003eAlarm load of 2.4A shared across all sounder outputs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of fire zones:\u003c\/strong\u003e 4 (4 to 12 with expansion)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZonal circuit configuration:\u003c\/strong\u003e Conventional or Twin Wire (selectable by DIL switches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e 3 colour-coded buttons (Resound, Silence and Reset), 1-4 numerical buttons and Enter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey switch input:\u003c\/strong\u003e Level 2 access enable key switch or code entry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board sounder circuits:\u003c\/strong\u003e 2 monitored (1A resettable fuse); a further two available with the high specification card\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 auxiliary clean changeover relays (1 Fire, 1 Fault), 3A max at 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50Hz (+10% \/ -15%), 1.2A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 28V DC 400mA continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable inputs:\u003c\/strong\u003e Class change and alert\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 2 x 7.0Ah 12V SLA, internal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger current:\u003c\/strong\u003e 1.34A (27.0V DC at 20°C, temperature compensated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking:\u003c\/strong\u003e Fully functional repeater panel via plug-in communications PCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Lockable steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 20 x top, 8 x rear, 4 x base (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Back box 300 x 450 x 85mm; door 310 x 460 x 25mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2:1997 + A1:2006; EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332036047221,"sku":"QZXL-4","price":421.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/8743_2nd.jpg?v=1771961018"},{"product_id":"advanced-qz-4-quickzone-4-zone-panel","title":"Advanced QZ-4 QuickZone - 4 Zone panel","description":"\u003cp\u003eThe Advanced QZ-4 QuickZone is a 4-zone conventional \/ Twin Wire (Sav-Wire) fire alarm control panel with integral power supply and space for standby batteries, approved to EN 54-2 and EN 54-4. It is easy to install and maintain and simple for the end user to operate.\u003c\/p\u003e\u003cp\u003eFour fire zone circuits are provided plus two monitored sounder circuits, fire and fault volt-free changeover relays, fire and fault switched negative outputs, and class change and alert inputs. It supports an extensive range of conventional fire detectors, including Apollo, Argus, Hochiki and Nittan; Twin Wire mode requires special 'Sav-Wire' detector bases and polarised 470 ohm call points.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 fire zones, conventional or Twin Wire (selectable by DIL switch)\u003c\/li\u003e\n\u003cli\u003e2 monitored sounder circuits\u003c\/li\u003e\n\u003cli\u003eFire and fault relays\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs\u003c\/li\u003e\n\u003cli\u003eSimple colour-coded buttons for controls and programming\u003c\/li\u003e\n\u003cli\u003eTest mode\u003c\/li\u003e\n\u003cli\u003eKey switch or code entry for activation of controls\u003c\/li\u003e\n\u003cli\u003eIntegral 1A switch mode PSU with space for up to 2 x 3.2Ah batteries\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of fire zones:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indicators:\u003c\/strong\u003e 5 red (1 x Fire, 4 x zonal), 1 green (Power), 13 amber (4 x zonal, 9 x Fault and System)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e 3 colour-coded buttons (Resound, Silence and Reset), 1-4 numerical buttons and Enter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey switch input:\u003c\/strong\u003e Level 2 access enable key switch or code entry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZonal circuit configuration:\u003c\/strong\u003e Conventional or Twin Wire (selectable by DIL switches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board sounder circuits:\u003c\/strong\u003e 2 monitored (fused 500mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 auxiliary clean changeover relays (1 Fire, 1 Fault), 3A max at 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 28V DC 400mA continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 2 x 3.2Ah 12V SLA, internal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger current:\u003c\/strong\u003e 630mA (27.0V DC at 20°C, temperature compensated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Lockable steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 13 x top, 7 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Back box 250 x 300 x 80mm; door 260 x 308 x 23mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2:1997 + A1:2006; EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332053807477,"sku":"QZ-4","price":297.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/8740.jpg?v=1771960988"},{"product_id":"advanced-qz-2-quickzone-2-zone-panel","title":"Advanced QZ-2 QuickZone - 2 Zone panel","description":"\u003cp\u003eThe Advanced QZ-2 QuickZone is a 2 zone conventional \/ twin wire (Sav-Wire) fire alarm control panel with an integral power supply and space for standby batteries. It is approved to EN 54-2 and EN 54-4 and supports a wide range of conventional detectors, including Apollo, Argus, Hochiki and Nittan.\u003c\/p\u003e\u003cp\u003eTwo fire zone circuits and two monitored sounder circuits are provided, with fire and fault volt-free changeover relays, fire and fault switched negative outputs, and class change and alert inputs. Twin wire mode is selected by DIL switch and needs Sav-Wire detector bases and polarised 470Ω call points.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 conventional or twin wire zones\u003c\/li\u003e\n\u003cli\u003e2 monitored sounder circuits\u003c\/li\u003e\n\u003cli\u003eFire and fault relays\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs\u003c\/li\u003e\n\u003cli\u003eType A dependency option\u003c\/li\u003e\n\u003cli\u003eTest mode\u003c\/li\u003e\n\u003cli\u003eKey switch or code entry for activation of controls\u003c\/li\u003e\n\u003cli\u003eSimple colour-coded buttons for control and programming\u003c\/li\u003e\n\u003cli\u003eIntegral 1A switch mode PSU with space for 2 x 3.2Ah batteries\u003c\/li\u003e\n\u003cli\u003eOne-year warranty as standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indicators:\u003c\/strong\u003e 5 red (1 x fire, 4 x zonal), 1 green (power), 13 amber (4 x zonal, 9 x fault and system)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder circuits:\u003c\/strong\u003e 2 monitored (500mA fused)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-board relays:\u003c\/strong\u003e 2 auxiliary clean changeover relays (1 fire, 1 fault), 3A max at 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50Hz (+10% \/ -15%), 1.0A max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 28V DC 400mA continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 2 x 3.2Ah 12V SLA, internal (batteries not included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger current:\u003c\/strong\u003e 630mA (27.0V DC at 20°C, temperature compensated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Lockable steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries:\u003c\/strong\u003e 13 x top, 7 x rear (20mm knockouts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e Back box 250 x 300 x 80mm; door 260 x 308 x 23mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2:1997 + A1:2006, EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332055740789,"sku":"QZ-2","price":253.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/8738_2nd.jpg?v=1771960979"},{"product_id":"c-tec-cfp-alarmsense-2-zone-2-wire-fire-alarm-panel-cfp702-2","title":"C-TEC CFP AlarmSense 2 Zone 2-Wire Fire Alarm Panel (CFP702-2)","description":"\u003ch2\u003eC-TEC CFP AlarmSense 2 Zone 2-Wire Fire Alarm Panel (CFP702-2)\u003c\/h2\u003e\n\u003cp\u003eLPCB certified to EN54-2\/4, C-TEC's CFP two-wire 2 zone AlarmSense fire panel is designed to work with Apollo's AlarmSense range of detectors, call points, sounders and visual indicators.\u003c\/p\u003e\n\u003cp\u003eMost conventional fire systems work with two pairs of wires per zone: one pair for detection devices; the other for alarm devices. By using different voltage bands for quiescent and alarm states, AlarmSense components can be connected to the same pair of supply wires. This reliable technology takes all of the complexity out of fire system design, leading to quicker, more flexible installation and around a 20-25% reduction of labour over a standard four wire system.\u003c\/p\u003e\n\u003cp\u003eThe CFP702-2 includes two AlarmSense zones, four conventional sounder circuits, class change \u0026amp; alert inputs and on-board fire \u0026amp; fault relays. A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities.\u003c\/p\u003e\n\u003cp\u003eKey Features of the CFP702-2\u003cbr\u003e\u003cbr\u003e\u0026gt; Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).\u003cbr\u003e\u0026gt; Intuitive user-friendly interface with colour-coded buttons and combined keypad\/keyswitch entry.\u003cbr\u003e\u0026gt; Manufactured by C-TEC in the UK.\u003cbr\u003e\u0026gt; Two AlarmSense zone circuits - compatible with Apollo's AlarmSense detectors, call points, sounders and visual indicators.\u003cbr\u003e\u0026gt; Four conventional sounder circuits.\u003cbr\u003e\u0026gt; Integral 1.5A EN54-4\/A2 compliant switch mode PSU.\u003cbr\u003e\u0026gt; Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.\u003cbr\u003e\u0026gt; Two on-board relays (Fire and Fault).\u003cbr\u003e\u0026gt; Two open-collector outputs (Remote and Reset).\u003cbr\u003e\u0026gt; 'Class change' and alert inputs.\u003cbr\u003e\u0026gt; Installer-friendly design.\u003cbr\u003e\u0026gt; Attractive flush or surface mountable plastic lid and enclosure - no bezel required.\u003cbr\u003e\u0026gt; Low 25mA quiescent current.\u003cbr\u003e\u0026gt; Multiple indicators.\u003cbr\u003e\u0026gt; System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).\u003cbr\u003e\u0026gt; Space for two x 12V 3.3Ah VRLA batteries.\u003c\/p\u003e","brand":"C-TEC","offers":[{"title":"Default Title","offer_id":56492160418165,"sku":"CFP702-2","price":158.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/C-TECCFPAlarmSense2Zone2-WireFireAlarmPanel_CFP702-2.webp?v=1766069478"},{"product_id":"kentec-sigma-cp-a-2-zone-alarmsense-fire-panel-ka11020m2","title":"Kentec Sigma CP-A 2 Zone Alarmsense Fire Panel (KA11020M2)","description":"\u003cp\u003eThe Kentec Sigma CP-A KA11020M2 is a 2 zone conventional fire alarm control panel for the Apollo AlarmSense two-wire system, certified to EN54-2 and EN54-4. AlarmSense lets compatible smoke and heat detectors, call points, sounders, sounder beacons and alarm relays share a single pair of wires on each zone, so separate sounder circuit cables are not needed. The panel has an integral, mains-powered power supply and battery charger.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with EN54-2 and EN54-4\u003c\/li\u003e\n\u003cli\u003e2 AlarmSense zones for Apollo AlarmSense detectors, call points, sounders, sounder beacons and alarm relays\u003c\/li\u003e\n\u003cli\u003eZoned or two-stage sounder operation without separate sounder cabling\u003c\/li\u003e\n\u003cli\u003ePriority\/non-priority sounder scheme: only the sounder local to the activated detector can be set to operate first, subject to a configurable alarm verification period; suited to Houses of Multiple Occupation and full compliance with BS 5839-6\u003c\/li\u003e\n\u003cli\u003eConfigurable alarm verification delay of 30, 60 or 120 seconds\u003c\/li\u003e\n\u003cli\u003eDedicated (common) sounder outputs in addition to the zonal sounders\u003c\/li\u003e\n\u003cli\u003eVolt-free fire, local fire and fault relay contacts\u003c\/li\u003e\n\u003cli\u003eTest mode with automatic resetting of zones for testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZones: 2 (AlarmSense)\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC +10%\/-15% (100W max)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge\u003c\/li\u003e\n\u003cli\u003eOutput voltage: 18.5 to 29V DC\u003c\/li\u003e\n\u003cli\u003eBatteries: two 12V sealed lead acid, 7Ah max\u003c\/li\u003e\n\u003cli\u003eStandby battery for a fully loaded panel: 3Ah (24h), 4.6Ah (48h)\u003c\/li\u003e\n\u003cli\u003eStandby current: 0.065A; max panel alarm current: 0.10A\u003c\/li\u003e\n\u003cli\u003eDetectors per zone: up to 20\u003c\/li\u003e\n\u003cli\u003eDedicated sounder outputs: 24V, 500mA each; zonal sounder outputs: 24V, 200mA; 1.6A total across all circuits\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fire, local fire, fault): 30V DC 1A max\u003c\/li\u003e\n\u003cli\u003eDetection circuit EOL: 3k3 resistor; sounder circuit EOL: 10k resistor (supplied)\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm²\u003c\/li\u003e\n\u003cli\u003eIP rating: IP30\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C, max 95% relative humidity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784507240821,"sku":"KA11020M2","price":288.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/11398_2nd.jpg?v=1771962668"},{"product_id":"kentec-sigma-cp-a-4-zone-alarmsense-fire-panel-ka11040m2","title":"Kentec Sigma CP-A 4 Zone Alarmsense Fire Panel (KA11040M2)","description":"\u003cp\u003eThe Kentec Sigma CP-A KA11040M2 is a 4 zone conventional fire alarm control panel for the Apollo AlarmSense two-wire system, certified to EN54-2 and EN54-4. AlarmSense lets compatible smoke and heat detectors, call points, sounders, sounder beacons and alarm relays share a single pair of wires on each zone, so separate sounder circuit cables are not needed. The panel has an integral, mains-powered power supply and battery charger.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with EN54-2 and EN54-4\u003c\/li\u003e\n\u003cli\u003eFour AlarmSense zones for Apollo AlarmSense detectors, call points, sounder bases, sounder beacon bases and alarm relays\u003c\/li\u003e\n\u003cli\u003ePriority\/non-priority sounder scheme: sounders can be set so that only the sounder near the activated detector operates first, subject to a configurable alarm verification period; ideal for Houses of Multiple Occupation and full compliance with BS 5839-6\u003c\/li\u003e\n\u003cli\u003eConfigurable alarm verification delay of 30, 60 or 120 seconds\u003c\/li\u003e\n\u003cli\u003eTwo common (conventional) sounder circuits in addition to the zonal sounders\u003c\/li\u003e\n\u003cli\u003eVolt-free fire, local fire and fault relay contacts\u003c\/li\u003e\n\u003cli\u003eTest mode with automatic resetting of zones for testing\u003c\/li\u003e\n\u003cli\u003eTwo seven-segment LED displays and MODE, SELECT and ENTER buttons for configuration\u003c\/li\u003e\n\u003cli\u003eConnections for repeater panels, ancillary boards and 8-way sounder boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZones: 4 (AlarmSense)\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC +10%\/-15% (100W max)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge\u003c\/li\u003e\n\u003cli\u003eOutput voltage: 18.5 to 29V DC\u003c\/li\u003e\n\u003cli\u003eBatteries: two 12V sealed lead acid, 7Ah max\u003c\/li\u003e\n\u003cli\u003eStandby battery for a fully loaded panel: 3.3Ah (24h), 5.1Ah (48h), 6.9Ah (72h)\u003c\/li\u003e\n\u003cli\u003eStandby current: 0.075A; max panel alarm current: 0.21A\u003c\/li\u003e\n\u003cli\u003eDetectors per zone: up to 20\u003c\/li\u003e\n\u003cli\u003eDedicated sounder outputs: 24V, 500mA each; zonal sounder outputs: 24V, 200mA; 1.6A total across all circuits\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fire, local fire, fault): 30V DC 1A max\u003c\/li\u003e\n\u003cli\u003eDetection circuit EOL: 3k3 resistor; sounder circuit EOL: 10k resistor (supplied)\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm²\u003c\/li\u003e\n\u003cli\u003eIP rating: IP30\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C, max 95% relative humidity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784507371893,"sku":"KA11040M2","price":363.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/11401_2nd.jpg?v=1771962678"},{"product_id":"kentec-sigma-cp-a-8-zone-alarmsense-fire-panel-ka11080m2","title":"Kentec Sigma CP-A 8 Zone Alarmsense Fire Panel (KA11080M2)","description":"\u003cp\u003eThe Kentec Sigma CP-A KA11080M2 is an 8 zone conventional fire alarm control panel for the Apollo AlarmSense two-wire system, certified to EN54-2 and EN54-4. AlarmSense lets compatible smoke and heat detectors, call points, sounders, sounder beacons and alarm relays share a single pair of wires on each zone, so separate sounder circuit cables are not needed. The panel has an integral, mains-powered power supply and battery charger.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with EN54-2 and EN54-4\u003c\/li\u003e\n\u003cli\u003e8 AlarmSense zones for Apollo AlarmSense detectors, call points, sounders, sounder beacons and alarm relays\u003c\/li\u003e\n\u003cli\u003eZoned or two-stage sounder operation without separate sounder cabling\u003c\/li\u003e\n\u003cli\u003ePriority\/non-priority sounder scheme: only the sounder local to the activated detector can be set to operate first, subject to a configurable alarm verification period; suited to Houses of Multiple Occupation and full compliance with BS 5839-6\u003c\/li\u003e\n\u003cli\u003eConfigurable alarm verification delay of 30, 60 or 120 seconds\u003c\/li\u003e\n\u003cli\u003eDedicated (common) sounder outputs in addition to the zonal sounders\u003c\/li\u003e\n\u003cli\u003eVolt-free fire, local fire and fault relay contacts\u003c\/li\u003e\n\u003cli\u003eTest mode with automatic resetting of zones for testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZones: 8 (AlarmSense)\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC +10%\/-15% (100W max)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge\u003c\/li\u003e\n\u003cli\u003eOutput voltage: 18.5 to 29V DC\u003c\/li\u003e\n\u003cli\u003eBatteries: two 12V sealed lead acid, 7Ah max\u003c\/li\u003e\n\u003cli\u003eStandby battery for a fully loaded panel: 3.75Ah (24h), 5.95Ah (48h)\u003c\/li\u003e\n\u003cli\u003eStandby current: 0.093A; max panel alarm current: 0.55A\u003c\/li\u003e\n\u003cli\u003eDetectors per zone: up to 20\u003c\/li\u003e\n\u003cli\u003eDedicated sounder outputs: 24V, 500mA each; zonal sounder outputs: 24V, 200mA; 1.6A total across all circuits\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fire, local fire, fault): 30V DC 1A max\u003c\/li\u003e\n\u003cli\u003eDetection circuit EOL: 3k3 resistor; sounder circuit EOL: 10k resistor (supplied)\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm²\u003c\/li\u003e\n\u003cli\u003eIP rating: IP30\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C, max 95% relative humidity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784507634037,"sku":"KA11080M2","price":324.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/11404_2nd.jpg?v=1771962696"},{"product_id":"zeta-infinity-id2-2-zone-intelligent-2-wire-fire-alarm-panel-id2-2","title":"Zeta Infinity ID2 2 Zone Intelligent 2-Wire Fire Alarm Panel (ID2\/2)","description":"\u003cp\u003eThe Zeta Infinity ID2\/2 is a 2-zone intelligent 2-wire fire alarm control panel. It gives the benefits of a 2-wire installation (less cable, quicker installation, lower labour and product costs) and can also individually identify ('I.D.') each device. The ID2 is built on Zeta's proven communication protocol and runs Zeta's MKII addressable devices. Detectors, call points, interfaces and sounders all connect to the same circuit.\u003c\/p\u003e\u003cp\u003eBecause ID2 devices sit on radial circuits, the panel suits new installations, retrofits to conventional systems, and replacement of existing 2-wire systems, often without re-wiring. It can also be wired as a single loop.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned to EN 54 parts 2 and 4; the system meets BS 5839 parts 1 and 6\u003c\/li\u003e\n\u003cli\u003eEach device uniquely identified by the panel, with 20-character zone and device descriptions\u003c\/li\u003e\n\u003cli\u003eDevice count verification and alarm verification\u003c\/li\u003e\n\u003cli\u003e2048-event history\u003c\/li\u003e\n\u003cli\u003eAll devices on 2-core zone cable, with no separate sounder circuits needed; loop-powered sounders supported\u003c\/li\u003e\n\u003cli\u003eDetectors available with integrated sandwich sounder\u003c\/li\u003e\n\u003cli\u003eCable break protection (loop mode) and short-circuit protection with isolators\u003c\/li\u003e\n\u003cli\u003eOne-man walk test, zone check facility and auto-configuration\u003c\/li\u003e\n\u003cli\u003eID2 smartphone app (iOS and Android) to help set device address switches\u003c\/li\u003e\n\u003cli\u003eSupports a fully functional repeater panel via RS-485\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModel: ID2\/2 (part no. 37-660)\u003c\/li\u003e\n\u003cli\u003eZones: 2; zone capacity 15 devices per zone\u003c\/li\u003e\n\u003cli\u003eDetection circuits: radial mode up to 8 radial circuits; loop mode 1 loop circuit\u003c\/li\u003e\n\u003cli\u003eMaximum loop sounder quantity: 80\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230 V AC +10% \/ -15% at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eSystem voltage: 29 V DC nominal (19–30 V)\u003c\/li\u003e\n\u003cli\u003eSounder output: 2 x conventional sounder circuits, 28 V nominal, 150 mA (20–30 V DC)\u003c\/li\u003e\n\u003cli\u003eFault output: 1 x fault relay, SELV at 1 A (normally energised)\u003c\/li\u003e\n\u003cli\u003eFire output: 1 x fire relay, SELV at 1 A\u003c\/li\u003e\n\u003cli\u003eRepeater connection: RS-485\u003c\/li\u003e\n\u003cli\u003eDimensions: 370 W x 311 H x 113 D mm\u003c\/li\u003e\n\u003cli\u003eApprovals: Kitemark KM 575040; CPR 2797-CPR-670814\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zeta","offers":[{"title":"Default Title","offer_id":56784929096053,"sku":"ID2\/2","price":306.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/infinityid2panel.jpg?v=1771971299"},{"product_id":"c-tec-cfp-alarmsense-4-zone-2-wire-fire-alarm-panel-cfp704-2","title":"C-TEC CFP AlarmSense 4 Zone 2-Wire Fire Alarm Panel (CFP704-2)","description":"\u003cp\u003eThe C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel (CFP704-2) is an LPCB certified EN 54-2\/4 control panel designed to work with Apollo's AlarmSense range. By using different voltage bands for quiescent and alarm states, AlarmSense detectors, call points, sounders and visual indicators can all be connected to the same pair of wires on each zone.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for Apollo AlarmSense detectors, call points, sounders and visual indicators: detection and alarm devices share the same pair of wires, giving around a 20-25% labour saving over a standard four-wire system\u003c\/li\u003e\n\u003cli\u003eFour additional conventional sounder circuits\u003c\/li\u003e\n\u003cli\u003eIntegral 1.5A EN 54-4\/A2 compliant switch mode PSU\u003c\/li\u003e\n\u003cli\u003eEngineering functions including zone test, coincidence (double knock), zone delays, non-latching zones and one-man walk test\u003c\/li\u003e\n\u003cli\u003eFire and fault relays (volt-free changeover, 1A 30V DC) and two open-collector outputs (remote and reset)\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs\u003c\/li\u003e\n\u003cli\u003eColour-coded buttons with combined keypad\/keyswitch entry\u003c\/li\u003e\n\u003cli\u003eFlush or surface mountable plastic enclosure, no bezel required\u003c\/li\u003e\n\u003cli\u003eExpansion for up to eight repeaters (one CFP761 network card per system), relay output cards and EN 54-13 sounder circuit boards\u003c\/li\u003e\n\u003cli\u003eManufactured in the UK by C-TEC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e CFP704-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarmSense zones:\u003c\/strong\u003e 4 (max. 500m per circuit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional sounder circuits:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50\/60Hz, 350mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal power supply:\u003c\/strong\u003e 19-28.5V (27V nominal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiescent current:\u003c\/strong\u003e 25mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah VRLA (in series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2\/4, LPCB certified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"C-TEC","offers":[{"title":"Default Title","offer_id":56784964026741,"sku":"CFP704-2","price":196.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/cfppanel-1_4.jpg?v=1771972211"},{"product_id":"c-tec-cfp-alarmsense-8-zone-2-wire-fire-alarm-panel-cfp708-2","title":"C-TEC CFP AlarmSense 8 Zone 2-Wire Fire Alarm Panel (CFP708-2)","description":"\u003cp\u003eThe C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel (CFP708-2) is an LPCB certified EN 54-2\/4 control panel designed to work with Apollo's AlarmSense range. By using different voltage bands for quiescent and alarm states, AlarmSense detectors, call points, sounders and visual indicators can all be connected to the same pair of wires on each zone.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for Apollo AlarmSense detectors, call points, sounders and visual indicators: detection and alarm devices share the same pair of wires, giving around a 20-25% labour saving over a standard four-wire system\u003c\/li\u003e\n\u003cli\u003eFour additional conventional sounder circuits\u003c\/li\u003e\n\u003cli\u003eIntegral 1.5A EN 54-4\/A2 compliant switch mode PSU\u003c\/li\u003e\n\u003cli\u003eEngineering functions including zone test, coincidence (double knock), zone delays, non-latching zones and one-man walk test\u003c\/li\u003e\n\u003cli\u003eFire and fault relays (volt-free changeover, 1A 30V DC) and two open-collector outputs (remote and reset)\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs\u003c\/li\u003e\n\u003cli\u003eColour-coded buttons with combined keypad\/keyswitch entry\u003c\/li\u003e\n\u003cli\u003eFlush or surface mountable plastic enclosure, no bezel required\u003c\/li\u003e\n\u003cli\u003eExpansion for up to eight repeaters (one CFP761 network card per system), relay output cards and EN 54-13 sounder circuit boards\u003c\/li\u003e\n\u003cli\u003eManufactured in the UK by C-TEC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e CFP708-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarmSense zones:\u003c\/strong\u003e 8 (max. 500m per circuit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per zone:\u003c\/strong\u003e Up to 25 AlarmSense detectors\/call points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional sounder circuits:\u003c\/strong\u003e 4 (max. 500m per circuit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSounder current:\u003c\/strong\u003e 200mA per circuit; total sounder load max. 1.25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V 50\/60Hz, 350mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal power supply:\u003c\/strong\u003e 19-28.5V (27V nominal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiescent current:\u003c\/strong\u003e 25mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah VRLA (in series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 380 x 235 x 96mm (W x H x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Plastic lid and base, RAL 7035 textured, IP30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.75kg without batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e EN 54-2\/4, LPCB certified (0832-CPR-F0386)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"C-TEC","offers":[{"title":"Default Title","offer_id":56784964092277,"sku":"CFP708-2","price":236.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/cfppanel-1_5.jpg?v=1771972214"},{"product_id":"fike-twinflexpro-2-zone-fire-alarm-panel-505-0002","title":"Fike TwinflexPro² 2 Zone Fire Alarm Panel (505-0002)","description":"\u003cp\u003eThe Fike TwinflexPro² 2 zone fire alarm control panel (505-0002) is the control panel for the Fike Twinflex intelligent 2-wire fire alarm system. The system uses a conventional cabling format but is classed as analogue non-addressable, and allows detectors and sounders to be connected on the same pair of wires, making it well suited to smaller applications such as shops, offices, schools, nursing homes, B\u0026amp;Bs, museums and restaurants.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntelligent 2-wire system: detectors, call points and sounders share one 2-core screened cable per zone\u003c\/li\u003e\n\u003cli\u003eUp to 32 Twinflex devices per zone\u003c\/li\u003e\n\u003cli\u003eIdentifies and displays whether an alarm came from a smoke detector, heat detector or manual call point\u003c\/li\u003e\n\u003cli\u003eMonitors each zone for detector head removal, device fault, end-of-line fault and open or short circuit\u003c\/li\u003e\n\u003cli\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli\u003eCheckpoint alarm confirmation to reduce false alarms; operating a call point overrides any delays or confirmation\u003c\/li\u003e\n\u003cli\u003eDay\/night detection mode per zone and 3 enhanced test modes\u003c\/li\u003e\n\u003cli\u003e500 event log\u003c\/li\u003e\n\u003cli\u003e2 monitored outputs configurable as conventional sounder circuits or 24V monitored relay circuits\u003c\/li\u003e\n\u003cli\u003eVolt-free common fire and common fault relays\u003c\/li\u003e\n\u003cli\u003eTwo multifunction latching\/non-latching inputs and one monitored programmable input (e.g. class change, remote fire)\u003c\/li\u003e\n\u003cli\u003eDual-purpose flush or surface housing\u003c\/li\u003e\n\u003cli\u003eProgrammable from the keypad or with TwinflexPro OSP PC software\u003c\/li\u003e\n\u003cli\u003eLPCB approved\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per zone:\u003c\/strong\u003e Up to 32 (up to 160 DLUs per zone)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice protocol:\u003c\/strong\u003e Twinflex V3 and TwinflexPro²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V AC nominal, 700mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePSU output:\u003c\/strong\u003e 2.1A (4 hour continuous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 24V DC nominal (21-31V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah sealed lead acid (not included), for up to 48 hours standby; 72 hours with the optional battery box and 2 x 12V 7Ah batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 250mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Common fire and common fault, volt-free SPCO, 1A 30V max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 2-core 1.5mm² screened fire-rated, up to 500m per zone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 331 x 331 x 99mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (excluding batteries):\u003c\/strong\u003e 2.25kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e V0 rated ABS, IP30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e 13 x 20mm knockouts and 1 x 50 x 50mm pull-out tab\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e BS EN 54-2 and BS EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":56784969597301,"sku":"505-0002","price":244.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/505-0002-1.jpg?v=1771972261"},{"product_id":"fike-twinflexpro-2-zone-fire-alarm-panel-black-505-0002-b","title":"Fike TwinflexPro² 2 Zone Fire Alarm Panel (Black) (505-0002-B)","description":"\u003cp\u003eThe Fike TwinflexPro² 2 zone fire alarm control panel (505-0002-B) in a black housing is the control panel for the Fike Twinflex intelligent 2-wire fire alarm system. The system uses a conventional cabling format but is classed as analogue non-addressable, and allows detectors and sounders to be connected on the same pair of wires, making it well suited to smaller applications such as shops, offices, schools, nursing homes, B\u0026amp;Bs, museums and restaurants.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntelligent 2-wire system: detectors, call points and sounders share one 2-core screened cable per zone\u003c\/li\u003e\n\u003cli\u003eUp to 32 Twinflex devices per zone\u003c\/li\u003e\n\u003cli\u003eIdentifies and displays whether an alarm came from a smoke detector, heat detector or manual call point\u003c\/li\u003e\n\u003cli\u003eMonitors each zone for detector head removal, device fault, end-of-line fault and open or short circuit\u003c\/li\u003e\n\u003cli\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli\u003eCheckpoint alarm confirmation to reduce false alarms; operating a call point overrides any delays or confirmation\u003c\/li\u003e\n\u003cli\u003eDay\/night detection mode per zone and 3 enhanced test modes\u003c\/li\u003e\n\u003cli\u003e500 event log\u003c\/li\u003e\n\u003cli\u003e2 monitored outputs configurable as conventional sounder circuits or 24V monitored relay circuits\u003c\/li\u003e\n\u003cli\u003eVolt-free common fire and common fault relays\u003c\/li\u003e\n\u003cli\u003eTwo multifunction latching\/non-latching inputs and one monitored programmable input (e.g. class change, remote fire)\u003c\/li\u003e\n\u003cli\u003eDual-purpose flush or surface housing\u003c\/li\u003e\n\u003cli\u003eProgrammable from the keypad or with TwinflexPro OSP PC software\u003c\/li\u003e\n\u003cli\u003eLPCB approved\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per zone:\u003c\/strong\u003e Up to 32 (up to 160 DLUs per zone)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice protocol:\u003c\/strong\u003e Twinflex V3 and TwinflexPro²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V AC nominal, 700mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePSU output:\u003c\/strong\u003e 2.1A (4 hour continuous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 24V DC nominal (21-31V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah sealed lead acid (not included), for up to 48 hours standby; 72 hours with the optional battery box and 2 x 12V 7Ah batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 250mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Common fire and common fault, volt-free SPCO, 1A 30V max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 2-core 1.5mm² screened fire-rated, up to 500m per zone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 331 x 331 x 99mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (excluding batteries):\u003c\/strong\u003e 2.25kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e V0 rated ABS, IP30, black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e 13 x 20mm knockouts and 1 x 50 x 50mm pull-out tab\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e BS EN 54-2 and BS EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":56784969662837,"sku":"505-0002-B","price":246.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/twinflexpro2blackpanel.jpg?v=1771972263"},{"product_id":"fike-twinflexpro-4-zone-fire-alarm-panel-black-505-0004-b","title":"Fike TwinflexPro² 4 Zone Fire Alarm Panel (Black) (505-0004-B)","description":"\u003cp\u003eThe Fike TwinflexPro² 4 zone fire alarm control panel (505-0004-B) in a black housing is the control panel for the Fike Twinflex intelligent 2-wire fire alarm system. The system uses a conventional cabling format but is classed as analogue non-addressable, and allows detectors and sounders to be connected on the same pair of wires, making it well suited to smaller applications such as shops, offices, schools, nursing homes, B\u0026amp;Bs, museums and restaurants. The 4 and 8 zone panels can also be fitted with the optional conventional zone card to accept conventional devices on zones 5 to 8.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntelligent 2-wire system: detectors, call points and sounders share one 2-core screened cable per zone\u003c\/li\u003e\n\u003cli\u003eUp to 32 Twinflex devices per zone\u003c\/li\u003e\n\u003cli\u003eIdentifies and displays whether an alarm came from a smoke detector, heat detector or manual call point\u003c\/li\u003e\n\u003cli\u003eMonitors each zone for detector head removal, device fault, end-of-line fault and open or short circuit\u003c\/li\u003e\n\u003cli\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli\u003eCheckpoint alarm confirmation to reduce false alarms; operating a call point overrides any delays or confirmation\u003c\/li\u003e\n\u003cli\u003eDay\/night detection mode per zone and 3 enhanced test modes\u003c\/li\u003e\n\u003cli\u003e500 event log\u003c\/li\u003e\n\u003cli\u003e2 monitored outputs configurable as conventional sounder circuits or 24V monitored relay circuits\u003c\/li\u003e\n\u003cli\u003eVolt-free common fire and common fault relays\u003c\/li\u003e\n\u003cli\u003eTwo multifunction latching\/non-latching inputs and one monitored programmable input (e.g. class change, remote fire)\u003c\/li\u003e\n\u003cli\u003eDual-purpose flush or surface housing\u003c\/li\u003e\n\u003cli\u003eProgrammable from the keypad or with TwinflexPro OSP PC software\u003c\/li\u003e\n\u003cli\u003eLPCB approved\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per zone:\u003c\/strong\u003e Up to 32 (up to 160 DLUs per zone)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice protocol:\u003c\/strong\u003e Twinflex V3 and TwinflexPro²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V AC nominal, 700mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePSU output:\u003c\/strong\u003e 2.1A (4 hour continuous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 24V DC nominal (21-31V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah sealed lead acid (not included), for up to 48 hours standby; 72 hours with the optional battery box and 2 x 12V 7Ah batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 250mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Common fire and common fault, volt-free SPCO, 1A 30V max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 2-core 1.5mm² screened fire-rated, up to 500m per zone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 331 x 331 x 99mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (excluding batteries):\u003c\/strong\u003e 2.28kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e V0 rated ABS, IP30, black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e 13 x 20mm knockouts and 1 x 50 x 50mm pull-out tab\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e BS EN 54-2 and BS EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":56784969695605,"sku":"505-0004-B","price":277.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/twinflexpro2blackpanel_1.jpg?v=1771972265"},{"product_id":"fike-twinflexpro-4-zone-fire-alarm-panel-505-0004","title":"Fike TwinflexPro² 4 Zone Fire Alarm Panel (505-0004)","description":"\u003cp\u003eThe Fike TwinflexPro² 4 zone fire alarm control panel (505-0004) is the control panel for the Fike Twinflex intelligent 2-wire fire alarm system. The system uses a conventional cabling format but is classed as analogue non-addressable, and allows detectors and sounders to be connected on the same pair of wires, making it well suited to smaller applications such as shops, offices, schools, nursing homes, B\u0026amp;Bs, museums and restaurants. The 4 and 8 zone panels can also be fitted with the optional conventional zone card to accept conventional devices on zones 5 to 8.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntelligent 2-wire system: detectors, call points and sounders share one 2-core screened cable per zone\u003c\/li\u003e\n\u003cli\u003eUp to 32 Twinflex devices per zone\u003c\/li\u003e\n\u003cli\u003eIdentifies and displays whether an alarm came from a smoke detector, heat detector or manual call point\u003c\/li\u003e\n\u003cli\u003eMonitors each zone for detector head removal, device fault, end-of-line fault and open or short circuit\u003c\/li\u003e\n\u003cli\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli\u003eCheckpoint alarm confirmation to reduce false alarms; operating a call point overrides any delays or confirmation\u003c\/li\u003e\n\u003cli\u003eDay\/night detection mode per zone and 3 enhanced test modes\u003c\/li\u003e\n\u003cli\u003e500 event log\u003c\/li\u003e\n\u003cli\u003e2 monitored outputs configurable as conventional sounder circuits or 24V monitored relay circuits\u003c\/li\u003e\n\u003cli\u003eVolt-free common fire and common fault relays\u003c\/li\u003e\n\u003cli\u003eTwo multifunction latching\/non-latching inputs and one monitored programmable input (e.g. class change, remote fire)\u003c\/li\u003e\n\u003cli\u003eDual-purpose flush or surface housing\u003c\/li\u003e\n\u003cli\u003eProgrammable from the keypad or with TwinflexPro OSP PC software\u003c\/li\u003e\n\u003cli\u003eLPCB approved\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per zone:\u003c\/strong\u003e Up to 32 (up to 160 DLUs per zone)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice protocol:\u003c\/strong\u003e Twinflex V3 and TwinflexPro²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V AC nominal, 700mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePSU output:\u003c\/strong\u003e 2.1A (4 hour continuous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 24V DC nominal (21-31V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah sealed lead acid (not included), for up to 48 hours standby; 72 hours with the optional battery box and 2 x 12V 7Ah batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 250mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Common fire and common fault, volt-free SPCO, 1A 30V max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 2-core 1.5mm² screened fire-rated, up to 500m per zone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 331 x 331 x 99mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (excluding batteries):\u003c\/strong\u003e 2.28kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e V0 rated ABS, IP30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e 13 x 20mm knockouts and 1 x 50 x 50mm pull-out tab\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e BS EN 54-2 and BS EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":56784969826677,"sku":"505-0004","price":293.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/505-0004-1.jpg?v=1771972267"},{"product_id":"fike-twinflexpro-8-zone-fire-alarm-panel-black-505-0008-b","title":"Fike TwinflexPro² 8 Zone Fire Alarm Panel (Black) (505-0008-B)","description":"\u003cp\u003eThe Fike TwinflexPro² 8 zone fire alarm control panel (505-0008-B) in a black housing is the control panel for the Fike Twinflex intelligent 2-wire fire alarm system. The system uses a conventional cabling format but is classed as analogue non-addressable, and allows detectors and sounders to be connected on the same pair of wires, making it well suited to smaller applications such as shops, offices, schools, nursing homes, B\u0026amp;Bs, museums and restaurants. The 4 and 8 zone panels can also be fitted with the optional conventional zone card to accept conventional devices on zones 5 to 8.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntelligent 2-wire system: detectors, call points and sounders share one 2-core screened cable per zone\u003c\/li\u003e\n\u003cli\u003eUp to 32 Twinflex devices per zone\u003c\/li\u003e\n\u003cli\u003eIdentifies and displays whether an alarm came from a smoke detector, heat detector or manual call point\u003c\/li\u003e\n\u003cli\u003eMonitors each zone for detector head removal, device fault, end-of-line fault and open or short circuit\u003c\/li\u003e\n\u003cli\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli\u003eCheckpoint alarm confirmation to reduce false alarms; operating a call point overrides any delays or confirmation\u003c\/li\u003e\n\u003cli\u003eDay\/night detection mode per zone and 3 enhanced test modes\u003c\/li\u003e\n\u003cli\u003e500 event log\u003c\/li\u003e\n\u003cli\u003e2 monitored outputs configurable as conventional sounder circuits or 24V monitored relay circuits\u003c\/li\u003e\n\u003cli\u003eVolt-free common fire and common fault relays\u003c\/li\u003e\n\u003cli\u003eTwo multifunction latching\/non-latching inputs and one monitored programmable input (e.g. class change, remote fire)\u003c\/li\u003e\n\u003cli\u003eDual-purpose flush or surface housing\u003c\/li\u003e\n\u003cli\u003eProgrammable from the keypad or with TwinflexPro OSP PC software\u003c\/li\u003e\n\u003cli\u003eLPCB approved\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per zone:\u003c\/strong\u003e Up to 32 (up to 160 DLUs per zone)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice protocol:\u003c\/strong\u003e Twinflex V3 and TwinflexPro²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V AC nominal, 700mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePSU output:\u003c\/strong\u003e 2.1A (4 hour continuous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 24V DC nominal (21-31V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah sealed lead acid (not included), for up to 48 hours standby; 72 hours with the optional battery box and 2 x 12V 7Ah batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 250mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Common fire and common fault, volt-free SPCO, 1A 30V max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 2-core 1.5mm² screened fire-rated, up to 500m per zone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 331 x 331 x 99mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (excluding batteries):\u003c\/strong\u003e 2.36kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e V0 rated ABS, IP30, black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e 13 x 20mm knockouts and 1 x 50 x 50mm pull-out tab\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e BS EN 54-2 and BS EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":56784969892213,"sku":"505-0008-B","price":382.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/twinflexpro2blackpanel_2.jpg?v=1771972270"},{"product_id":"fike-twinflexpro-8-zone-fire-alarm-panel-505-0008","title":"Fike TwinflexPro² 8 Zone Fire Alarm Panel (505-0008)","description":"\u003cp\u003eThe Fike TwinflexPro² 8 zone fire alarm control panel (505-0008) is the control panel for the Fike Twinflex intelligent 2-wire fire alarm system. The system uses a conventional cabling format but is classed as analogue non-addressable, and allows detectors and sounders to be connected on the same pair of wires, making it well suited to smaller applications such as shops, offices, schools, nursing homes, B\u0026amp;Bs, museums and restaurants. The 4 and 8 zone panels can also be fitted with the optional conventional zone card to accept conventional devices on zones 5 to 8.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntelligent 2-wire system: detectors, call points and sounders share one 2-core screened cable per zone\u003c\/li\u003e\n\u003cli\u003eUp to 32 Twinflex devices per zone\u003c\/li\u003e\n\u003cli\u003eIdentifies and displays whether an alarm came from a smoke detector, heat detector or manual call point\u003c\/li\u003e\n\u003cli\u003eMonitors each zone for detector head removal, device fault, end-of-line fault and open or short circuit\u003c\/li\u003e\n\u003cli\u003e4 line x 20 character LCD display\u003c\/li\u003e\n\u003cli\u003eCheckpoint alarm confirmation to reduce false alarms; operating a call point overrides any delays or confirmation\u003c\/li\u003e\n\u003cli\u003eDay\/night detection mode per zone and 3 enhanced test modes\u003c\/li\u003e\n\u003cli\u003e500 event log\u003c\/li\u003e\n\u003cli\u003e2 monitored outputs configurable as conventional sounder circuits or 24V monitored relay circuits\u003c\/li\u003e\n\u003cli\u003eVolt-free common fire and common fault relays\u003c\/li\u003e\n\u003cli\u003eTwo multifunction latching\/non-latching inputs and one monitored programmable input (e.g. class change, remote fire)\u003c\/li\u003e\n\u003cli\u003eDual-purpose flush or surface housing\u003c\/li\u003e\n\u003cli\u003eProgrammable from the keypad or with TwinflexPro OSP PC software\u003c\/li\u003e\n\u003cli\u003eLPCB approved\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per zone:\u003c\/strong\u003e Up to 32 (up to 160 DLUs per zone)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice protocol:\u003c\/strong\u003e Twinflex V3 and TwinflexPro²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains supply:\u003c\/strong\u003e 230V AC nominal, 700mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePSU output:\u003c\/strong\u003e 2.1A (4 hour continuous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 24V DC nominal (21-31V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 2 x 12V 3.2Ah sealed lead acid (not included), for up to 48 hours standby; 72 hours with the optional battery box and 2 x 12V 7Ah batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary supply:\u003c\/strong\u003e 250mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Common fire and common fault, volt-free SPCO, 1A 30V max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 2-core 1.5mm² screened fire-rated, up to 500m per zone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 331 x 331 x 99mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (excluding batteries):\u003c\/strong\u003e 2.36kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e V0 rated ABS, IP30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e 13 x 20mm knockouts and 1 x 50 x 50mm pull-out tab\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 5°C to 40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e BS EN 54-2 and BS EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":56784969990517,"sku":"505-0008","price":378.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/505-0004-1_1.jpg?v=1771972272"},{"product_id":"haes-alarmsense-2-zone-fire-alarm-control-panel-als-2","title":"HAES AlarmSense 2 Zone Fire Alarm Control Panel (ALS-2)","description":"\u003cp\u003eThe HAES AlarmSense 2 zone (ALS-2) is a compact fire alarm control panel for use with Apollo's AlarmSense range of 2-wire devices. It provides 2 AlarmSense zones and 2 conventional monitored sounder outputs.\u003c\/p\u003e\u003cp\u003eNon-priority alarm and coincidence alarm can be selected per zone, and controls are activated by key switch or code entry. Note that this panel does not support repeater panels.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 x AlarmSense zones\u003c\/li\u003e\n\u003cli\u003eCompatible with the Apollo AlarmSense range of devices\u003c\/li\u003e\n\u003cli\u003eControls activated by key switch or code entry\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003e1.25A switch mode power supply, nominal 27V DC\u003c\/li\u003e\n\u003cli\u003e2 conventional monitored sounder outputs, fused at 500mA (resettable)\u003c\/li\u003e\n\u003cli\u003e2 voltage-free changeover relays (1 x Fire, 1 x Fault)\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs; fire and fault switched -ve outputs\u003c\/li\u003e\n\u003cli\u003eTest mode with or without sounders; disable zones, sounder outputs and aux outputs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 300mm W x 250mm H x 80mm D; lid 308mm W x 260mm H x 23mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: 1.25A internal switch mode PSU, nominal 27V DC\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 2 x 3.2Ah 12V VRSLA\u003c\/li\u003e\n\u003cli\u003eDetection zones: 2 x AlarmSense protocol, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x conventional monitored, fused at 500mA, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 1 x Fire, 1 x Fault, 3A 30V volt-free changeover\u003c\/li\u003e\n\u003cli\u003eOutputs: 1 x Fire, 1 x Fault, 40mA switched -ve\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: class change and alert (pulsing)\u003c\/li\u003e\n\u003cli\u003eNon-priority alarm: selectable per zone\u003c\/li\u003e\n\u003cli\u003eCoincidence alarm: selectable per zone\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784971366773,"sku":"ALS-2","price":164.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/haesals-1.jpg?v=1771972311"},{"product_id":"haes-alarmsense-4-zone-fire-alarm-control-panel-als-4","title":"HAES AlarmSense 4 Zone Fire Alarm Control Panel (ALS-4)","description":"\u003cp\u003eThe HAES AlarmSense ALS-4 is a 4-zone fire alarm control panel for Apollo's AlarmSense range of 2-wire devices. Each zone uses the AlarmSense protocol, and the panel also has two conventional monitored sounder circuits. Repeater panels are not supported.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 x AlarmSense zones, compatible with Apollo AlarmSense devices\u003c\/li\u003e\n\u003cli\u003eControls activated by key switch or code entry\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003e2 x conventional monitored sounder outputs, fused at 500 mA with resettable fuses\u003c\/li\u003e\n\u003cli\u003eFire and fault volt-free relays; fire and fault switched -ve outputs\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs\u003c\/li\u003e\n\u003cli\u003eNon-priority alarm and coincidence alarm selectable per zone\u003c\/li\u003e\n\u003cli\u003eTest mode with or without sounders; disablement of zones, sounder outputs and aux outputs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2 mm mild steel, IP30, colour ref. MW334E Interpon powder coat\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 300 W x 250 H x 80 D mm; lid 308 W x 260 H x 23 D mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 1.25 A internal switch-mode PSU, nominal 27 V DC\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 2 x 3.2 Ah 12 V VRSLA\u003c\/li\u003e\n\u003cli\u003eDetection zones: 4 x AlarmSense protocol, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x conventional monitored, fused at 500 mA, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 1 x fire, 1 x fault, 3 A, 30 V volt-free changeover\u003c\/li\u003e\n\u003cli\u003eOutputs: 1 x fire, 1 x fault, 40 mA switched -ve\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784971497845,"sku":"ALS-4","price":196.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/haesals-1_1.jpg?v=1771972315"},{"product_id":"haes-alarmsense-plus-4-zone-fire-alarm-control-panel-asp-4","title":"HAES AlarmSense PLUS 4 Zone Fire Alarm Control Panel (ASP-4)","description":"\u003cp\u003eThe HAES AlarmSense PLUS 4 zone (ASP-4) is a fire alarm control panel for use with Apollo's AlarmSense range of 2-wire devices. It has 4 AlarmSense zones, is expandable to 12 zones and is suitable for use with a fully functional repeater panel.\u003c\/p\u003e\u003cp\u003eNon-priority alarm and coincidence alarm can be selected per zone, and controls are activated by key switch or code entry.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 x AlarmSense zones\u003c\/li\u003e\n\u003cli\u003eCompatible with the Apollo AlarmSense range of devices\u003c\/li\u003e\n\u003cli\u003eControls activated by key switch or code entry\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003e3A switch mode power supply, nominal 27V DC\u003c\/li\u003e\n\u003cli\u003e2 conventional monitored sounder outputs, fused at 500mA (resettable)\u003c\/li\u003e\n\u003cli\u003e2 voltage-free changeover relays (1 x Fire, 1 x Fault)\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs; fire and fault switched -ve outputs\u003c\/li\u003e\n\u003cli\u003eTest mode with or without sounders; disable zones, sounder outputs and aux outputs\u003c\/li\u003e\n\u003cli\u003eFully functional repeater available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 450mm W x 300mm H x 85mm D; lid 460mm W x 310mm H x 25mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: 3A internal switch mode PSU, nominal 27V DC\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 2 x 7.0Ah 12V VRSLA\u003c\/li\u003e\n\u003cli\u003eDetection zones: 4 x AlarmSense protocol, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x conventional monitored, fused at 500mA, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 1 x Fire, 1 x Fault, 3A 30V volt-free changeover\u003c\/li\u003e\n\u003cli\u003eOutputs: 1 x Fire, 1 x Fault, 40mA switched -ve\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: class change and alert (pulsing)\u003c\/li\u003e\n\u003cli\u003eEvent log: 40 events\u003c\/li\u003e\n\u003cli\u003eNon-priority alarm: selectable per zone\u003c\/li\u003e\n\u003cli\u003eCoincidence alarm: selectable per zone\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784971628917,"sku":"ASP-4","price":282.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/haesasp-1.jpg?v=1771972321"},{"product_id":"haes-alarmsense-plus-8-zone-fire-alarm-control-panel-asp-8","title":"HAES AlarmSense PLUS 8 Zone Fire Alarm Control Panel (ASP-8)","description":"\u003cp\u003eThe HAES AlarmSense PLUS 8 zone (ASP-8) is a fire alarm control panel for use with Apollo's AlarmSense range of 2-wire devices. It has 8 AlarmSense zones, is expandable to 12 zones and is suitable for use with a fully functional repeater panel.\u003c\/p\u003e\u003cp\u003eNon-priority alarm and coincidence alarm can be selected per zone, and controls are activated by key switch or code entry.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 x AlarmSense zones\u003c\/li\u003e\n\u003cli\u003eCompatible with the Apollo AlarmSense range of devices\u003c\/li\u003e\n\u003cli\u003eControls activated by key switch or code entry\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003e3A switch mode power supply, nominal 27V DC\u003c\/li\u003e\n\u003cli\u003e2 conventional monitored sounder outputs, fused at 500mA (resettable)\u003c\/li\u003e\n\u003cli\u003e2 voltage-free changeover relays (1 x Fire, 1 x Fault)\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs; fire and fault switched -ve outputs\u003c\/li\u003e\n\u003cli\u003eTest mode with or without sounders; disable zones, sounder outputs and aux outputs\u003c\/li\u003e\n\u003cli\u003eFully functional repeater available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 450mm W x 300mm H x 85mm D; lid 460mm W x 310mm H x 25mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: 3A internal switch mode PSU, nominal 27V DC\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 2 x 7.0Ah 12V VRSLA\u003c\/li\u003e\n\u003cli\u003eDetection zones: 8 x AlarmSense protocol, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x conventional monitored, fused at 500mA, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 1 x Fire, 1 x Fault, 3A 30V volt-free changeover\u003c\/li\u003e\n\u003cli\u003eOutputs: 1 x Fire, 1 x Fault, 40mA switched -ve\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: class change and alert (pulsing)\u003c\/li\u003e\n\u003cli\u003eEvent log: 40 events\u003c\/li\u003e\n\u003cli\u003eNon-priority alarm: selectable per zone\u003c\/li\u003e\n\u003cli\u003eCoincidence alarm: selectable per zone\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784974184821,"sku":"ASP-8","price":274.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/haesasp-1_1.jpg?v=1771972332"},{"product_id":"haes-alarmsense-plus-12-zone-fire-alarm-control-panel-asp-12","title":"HAES AlarmSense PLUS 12 Zone Fire Alarm Control Panel (ASP-12)","description":"\u003cp\u003eThe HAES AlarmSense PLUS ASP-12 is a 12 zone fire alarm control panel for Apollo's AlarmSense range of 2-wire devices. It provides 12 AlarmSense zones plus two conventional monitored sounder circuits, and is suitable for use with a fully functional repeater panel via a plug-in comms PCB.\u003c\/p\u003e\u003cp\u003eNon-priority alarm and coincidence alarm can be selected per zone, and controls are activated by key switch or code entry. AlarmSense PLUS panels are approved to EN54-2 and EN54-4.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e12 x AlarmSense zones\u003c\/li\u003e\n\u003cli\u003eCompatible with the Apollo AlarmSense range of devices\u003c\/li\u003e\n\u003cli\u003eControls activated by key switch or code entry\u003c\/li\u003e\n\u003cli\u003eIntegral detector removal monitoring\u003c\/li\u003e\n\u003cli\u003e3A switch mode power supply, nominal 27V DC\u003c\/li\u003e\n\u003cli\u003e2 conventional monitored sounder outputs, fused at 500mA (resettable)\u003c\/li\u003e\n\u003cli\u003e2 voltage-free changeover relays (1 x Fire, 1 x Fault)\u003c\/li\u003e\n\u003cli\u003eClass change and alert inputs; fire and fault switched -ve outputs\u003c\/li\u003e\n\u003cli\u003eTest mode with or without sounders; disable zones, sounder outputs and aux outputs\u003c\/li\u003e\n\u003cli\u003eFully functional repeater available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 450mm W x 300mm H x 85mm D; lid 460mm W x 310mm H x 25mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC +10%\/-15% 50Hz, max current 1.2A\u003c\/li\u003e\n\u003cli\u003ePower supply: 3A internal switch mode, nominal 27V DC; maximum load shared between outputs 2.4A\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 2 x 7.0Ah 12V VRSLA\u003c\/li\u003e\n\u003cli\u003eDetection zones: 12 x AlarmSense protocol, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eZone circuits: monitoring current limit 50mA, fused at 200mA; typical max load 20 alarm devices at 18mA each\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x monitored, fused at 500mA, EOL 3K3\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 2 x programmable, 3A 30V volt-free changeover\u003c\/li\u003e\n\u003cli\u003eOutputs: 2 x programmable 40mA switched -ve\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: class change and alert (pulsing)\u003c\/li\u003e\n\u003cli\u003eEvent log: 40 events\u003c\/li\u003e\n\u003cli\u003eNon-priority alarm: selectable per zone\u003c\/li\u003e\n\u003cli\u003eCoincidence alarm: selectable per zone\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784974283125,"sku":"ASP-12","price":441.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/haesasp-1_2.jpg?v=1771972336"},{"product_id":"zeta-infinity-id2-4-zone-intelligent-2-wire-fire-alarm-panel-id2-4","title":"Zeta Infinity ID2 4 Zone Intelligent 2-Wire Fire Alarm Panel (ID2\/4)","description":"\u003cp\u003eThe Zeta Infinity ID2\/4 is a 4-zone intelligent 2-wire fire alarm control panel. It gives the benefits of a 2-wire installation (less cable, quicker installation, lower labour and product costs) and can also individually identify ('I.D.') each device. The ID2 is built on Zeta's proven communication protocol and runs Zeta's MKII addressable devices. Detectors, call points, interfaces and sounders all connect to the same circuit.\u003c\/p\u003e\u003cp\u003eBecause ID2 devices sit on radial circuits, the panel suits new installations, retrofits to conventional systems, and replacement of existing 2-wire systems, often without re-wiring. It can also be wired as a single loop.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned to EN 54 parts 2 and 4; the system meets BS 5839 parts 1 and 6\u003c\/li\u003e\n\u003cli\u003eEach device uniquely identified by the panel, with 20-character zone and device descriptions\u003c\/li\u003e\n\u003cli\u003eDevice count verification and alarm verification\u003c\/li\u003e\n\u003cli\u003e2048-event history\u003c\/li\u003e\n\u003cli\u003eAll devices on 2-core zone cable, with no separate sounder circuits needed; loop-powered sounders supported\u003c\/li\u003e\n\u003cli\u003eDetectors available with integrated sandwich sounder\u003c\/li\u003e\n\u003cli\u003eCable break protection (loop mode) and short-circuit protection with isolators\u003c\/li\u003e\n\u003cli\u003eOne-man walk test, zone check facility and auto-configuration\u003c\/li\u003e\n\u003cli\u003eID2 smartphone app (iOS and Android) to help set device address switches\u003c\/li\u003e\n\u003cli\u003eSupports a fully functional repeater panel via RS-485\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModel: ID2\/4 (part no. 37-661)\u003c\/li\u003e\n\u003cli\u003eZones: 4; zone capacity 15 devices per zone\u003c\/li\u003e\n\u003cli\u003eDetection circuits: radial mode up to 8 radial circuits; loop mode 1 loop circuit\u003c\/li\u003e\n\u003cli\u003eMaximum loop sounder quantity: 80\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230 V AC +10% \/ -15% at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eSystem voltage: 29 V DC nominal (19–30 V)\u003c\/li\u003e\n\u003cli\u003eSounder output: 2 x conventional sounder circuits, 28 V nominal, 150 mA (20–30 V DC)\u003c\/li\u003e\n\u003cli\u003eFault output: 1 x fault relay, SELV at 1 A (normally energised)\u003c\/li\u003e\n\u003cli\u003eFire output: 1 x fire relay, SELV at 1 A\u003c\/li\u003e\n\u003cli\u003eRepeater connection: RS-485\u003c\/li\u003e\n\u003cli\u003eDimensions: 370 W x 311 H x 113 D mm\u003c\/li\u003e\n\u003cli\u003eApprovals: Kitemark KM 575040; CPR 2797-CPR-670814\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zeta","offers":[{"title":"Default Title","offer_id":56784974479733,"sku":"ID2\/4","price":314.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/infinityid2panel_1.jpg?v=1771972345"},{"product_id":"zeta-infinity-id2-8-zone-intelligent-2-wire-fire-alarm-panel-id2-8","title":"Zeta Infinity ID2 8 Zone Intelligent 2-Wire Fire Alarm Panel (ID2\/8)","description":"\u003cp\u003eThe Zeta Infinity ID2\/8 is an 8-zone intelligent 2-wire fire alarm panel. It gives all the benefits of a 2-wire installation (less cable, quicker installation and savings on labour and product) while also identifying each individual device, so the panel reports the exact location of an alarm or fault.\u003c\/p\u003e\u003cp\u003eThe ID2 uses Zeta's MKII protocol and can run Zeta's addressable detectors, call points, interfaces and sounders. It can be wired as a single loop or as up to 8 radial circuits, which makes it suitable for new installations, as a retrofit for a conventional system using the existing wiring, or as a replacement for an existing 2-wire system.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 zones; loop or radial wiring (up to 8 radial circuits)\u003c\/li\u003e\n\u003cli\u003eEach device uniquely identified by the panel\u003c\/li\u003e\n\u003cli\u003eDesigned to meet EN 54-2 and EN 54-4; system meets BS 5839-1 and BS 5839-6\u003c\/li\u003e\n\u003cli\u003eNo end-of-line devices required; all devices on 2-core zone cable\u003c\/li\u003e\n\u003cli\u003eDetectors available with integrated sounder, so no separate sounder circuits are needed\u003c\/li\u003e\n\u003cli\u003eAlarm verification to help manage unwanted alarms\u003c\/li\u003e\n\u003cli\u003eDevice count verification and Zone Check facility\u003c\/li\u003e\n\u003cli\u003e2048-event history\u003c\/li\u003e\n\u003cli\u003eCable break protection (loop mode) and short-circuit protection with isolators\u003c\/li\u003e\n\u003cli\u003e20-character zone and device descriptions\u003c\/li\u003e\n\u003cli\u003eOne-man walk test; zone and sounder circuit isolation\u003c\/li\u003e\n\u003cli\u003eID2 smartphone app (iOS and Android) to help set device addresses\u003c\/li\u003e\n\u003cli\u003eSupports a fully functional repeater panel and GSM communicator\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModel \/ part no.: ID2\/8 (37-663)\u003c\/li\u003e\n\u003cli\u003eSupply: 230 V AC +10% \/ -15% at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eSystem voltage: 29 V DC nominal (19-30 V)\u003c\/li\u003e\n\u003cli\u003eSounder outputs: loop-powered sounders plus 2 conventional sounder circuits, 28 V nominal, 150 mA\u003c\/li\u003e\n\u003cli\u003eFault relay: SELV at 1 A (normally energised)\u003c\/li\u003e\n\u003cli\u003eFire relay: SELV at 1 A\u003c\/li\u003e\n\u003cli\u003eZones: 8; zone capacity 15 devices per zone\u003c\/li\u003e\n\u003cli\u003eMaximum loop sounders: 80\u003c\/li\u003e\n\u003cli\u003eRepeater connection: RS485\u003c\/li\u003e\n\u003cli\u003eDimensions: 370 (W) x 311 (H) x 113 (D) mm\u003c\/li\u003e\n\u003cli\u003eWeight: 2.65 kg\u003c\/li\u003e\n\u003cli\u003eKitemark certificate KM 575040; CPR 2797-CPR-670814\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zeta","offers":[{"title":"Default Title","offer_id":56784974512501,"sku":"ID2\/8","price":382.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/infinityid2panel_2.jpg?v=1771972348"},{"product_id":"c-tec-fp4e-4-zone-economy-fire-panel-c-tec","title":"C-Tec FP4E 4 Zone economy fire panel C-TEC","description":"\u003cp\u003eThe C-TEC FF384-3 is a 4 zone economy conventional fire alarm panel from C-TEC's FP range, in a metal enclosure. It is designed to comply with BS 5839-4 and works with most conventional fire detectors, including C-TEC's ActiV range. C-TEC states that this panel is not compliant with EN54-2\/4 and should not be used in new UK or European installations.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour conventional detector zone circuits and two conventional sounder circuits\u003c\/li\u003e\n\u003cli\u003eMetal enclosure with lift-off lid and heavy-duty base connections\u003c\/li\u003e\n\u003cli\u003eSeparate indicators for open and short circuit fault, sounder fault and battery\/power supply fault\u003c\/li\u003e\n\u003cli\u003eShort circuit = fire facility (pre-1980 BS, no resistors in call points), selectable zone by zone\u003c\/li\u003e\n\u003cli\u003eNon-latching class change sounder output; latching fire and non-latching fault outputs via optional expansion loom\u003c\/li\u003e\n\u003cli\u003eConnections for repeaters and add-ons such as fault, fire and sounder delay relay modules and sounder extender kits\u003c\/li\u003e\n\u003cli\u003eSpace for 2 x 12V 2.3Ah VRLA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOrder code: FF384-3\u003c\/li\u003e\n\u003cli\u003eStandard: designed to comply with BS 5839-4 (for head-out monitoring use 1 x BF378M per zone)\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V 50\/60Hz, 185mA maximum\u003c\/li\u003e\n\u003cli\u003eInternal power supply: 27V nominal; total output current limited to 800mA\u003c\/li\u003e\n\u003cli\u003eQuiescent current: 50mA\u003c\/li\u003e\n\u003cli\u003eBatteries: 2 x 12V 2.3Ah VRLA in series\u003c\/li\u003e\n\u003cli\u003eDetector zones: 4 (maximum 500m per circuit); up to 20 detectors per zone (maximum detector current 2mA), no limit on manual call points\u003c\/li\u003e\n\u003cli\u003eCall point resistor value: 470 to 680Ω\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 (maximum 500m per circuit), 800mA total, fused at 1A\u003c\/li\u003e\n\u003cli\u003eEnd-of-line resistor: 6800Ω\u003c\/li\u003e\n\u003cli\u003eAuxiliary relay: 1 x on-board (1A, 30V DC, follows sounders)\u003c\/li\u003e\n\u003cli\u003eControls: reset, resound, lamp test, evacuate, silence alarm, silence fault, S\/C = fire, one-man test, zone isolate; keyswitch\u003c\/li\u003e\n\u003cli\u003eRepeaters: up to 3 per main panel, maximum cable length 200m\u003c\/li\u003e\n\u003cli\u003eDimensions: 322 W x 267 H x 92 D mm\u003c\/li\u003e\n\u003cli\u003eConstruction: metal lid and base\u003c\/li\u003e\n\u003cli\u003eIP rating: IP30\u003c\/li\u003e\n\u003cli\u003eWeight: 4.3kg\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C, maximum 95% relative humidity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"C-TEC","offers":[{"title":"Default Title","offer_id":57305407488373,"sku":"FF384-3\/C-TEC","price":246.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEMUK_c026c890-1f8d-4508-84e2-23755e3f451f.jpg?v=1782125568"}],"url":"https:\/\/jemsystems.co.uk\/collections\/conventional-fire-alarm-panels.oembed","provider":"JEM Systems UK","version":"1.0","type":"link"}