{"title":"Extinguishant Control Panels","description":"\u003cp\u003eExtinguishant control panels, also called extinguishing or suppression control panels, monitor detection and control the release of an extinguishing agent in a protected area such as a server room, archive or plant room. They are designed to work alongside gas suppression systems, with controls for delay, abort, hold and manual release.\u003c\/p\u003e\u003cp\u003eThis range includes conventional and addressable extinguishant control panels from brands including Kentec, HAES, Advanced, C-TEC, Notifier and Comelit. Zone, area and loop counts are listed in each product title. Models range from single-area panels to multi-area panels covering several protected spaces.\u003c\/p\u003e\u003ch2\u003eChoosing an extinguishant panel\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAreas and zones:\u003c\/strong\u003e count the separate protected areas and the detection zones within each one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection type:\u003c\/strong\u003e choose a conventional panel for zone-based detection or an addressable panel for loop-based detection and protocol compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e extinguishant control equipment is covered by EN 12094-1, and system design should be carried out by a competent person.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor general fire detection control panels, see our \u003ca href=\"\/collections\/fire-alarm-panels\"\u003efire alarm panels\u003c\/a\u003e range, including \u003ca href=\"\/collections\/conventional-fire-alarm-panels\"\u003econventional\u003c\/a\u003e and \u003ca href=\"\/collections\/addressable-fire-alarm-panels\"\u003eaddressable\u003c\/a\u003e models. Manufacturer ranges include \u003ca href=\"\/collections\/kentec\"\u003eKentec\u003c\/a\u003e and \u003ca href=\"\/collections\/haes\"\u003eHAES\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"advanced-ex-3001-extinguishing-control-panel-3-detection-zones-single-release-output","title":"Advanced EX-3001 ExGo Extinguishing Control Panel with 3 Detection Zones","description":"\u003cp\u003eThe Advanced EX-3001 ExGo is a three-zone automatic gas extinguishing control panel with one release (extinguishing) output. It detects a fire in the same way as a fire alarm panel but also controls the release of the extinguishing agent, from CO2 to specialist gases such as aerosol and clean agents.\u003c\/p\u003e\u003cp\u003eIt is approved to EN 12094-1 and EN 54 parts 2, 4 and 13, and is typically used to protect high-value or strategically important areas such as computer suites, telecoms switch rooms and battery energy storage systems (BESS).\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3 conventional detection zones, including support for I.S. barriers\u003c\/li\u003e\n\u003cli\u003e1 flooding \/ extinguishing zone supporting solenoid and Metron type actuators\u003c\/li\u003e\n\u003cli\u003eLCD display for clear status indication and programming, with large digital countdown timer\u003c\/li\u003e\n\u003cli\u003ePasscode or optional key switch for Level 2 access\u003c\/li\u003e\n\u003cli\u003eTime- and date-stamped event log with improved diagnostics\u003c\/li\u003e\n\u003cli\u003eRS485 connection for up to 7 remote status indicators\u003c\/li\u003e\n\u003cli\u003ePC download of configuration and event logs via USB\u003c\/li\u003e\n\u003cli\u003eCompany logo can be displayed on the LCD in normal conditions\u003c\/li\u003e\n\u003cli\u003eMultiple languages, with customisable slide-in labels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBase technology: flash-based processor\u003c\/li\u003e\n\u003cli\u003eDisplay: backlit 128 x 64 LCD\u003c\/li\u003e\n\u003cli\u003eDetection zones: 3 x conventional\u003c\/li\u003e\n\u003cli\u003eExtinguishing zones: 1 x; solenoid (1 A continuous load) and Metron (3 A, 15 ms pulse) actuators\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 3 x 1 A, 18-28 V DC\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V DC (Fire, Fault and 2 x programmable)\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 500 mA, 18-28 V DC (1 switched)\u003c\/li\u003e\n\u003cli\u003eProgrammable outputs: 8 additional via EXP-008\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: 4 x programmable, 1 x manual trigger, 6 x release (Mode Select, Valve Monitor, Pressure Monitor, Hold, Abort, Flow)\u003c\/li\u003e\n\u003cli\u003eRemote status indicators: up to 7 via RS485\u003c\/li\u003e\n\u003cli\u003eMains supply: 3 A universal switch-mode PSU\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 7 Ah; charger current 1 A\u003c\/li\u003e\n\u003cli\u003eUSB: 1 x for PC connection\u003c\/li\u003e\n\u003cli\u003eEvent log: 100 fire\/trigger events, 500 general events\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, grey RAL 7035\u003c\/li\u003e\n\u003cli\u003eCable entry: 17 knockouts in top, 13 in back\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 330 x 400 x 90 mm; weight 6 kg\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 12094-1, EN 54-2, EN 54-4, EN 54-13\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332026839413,"sku":"EX-3001","price":614.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/ex-3001-1.jpg?v=1771961036"},{"product_id":"notifier-europe-nfs3-ext","title":"Notifier Europe NFS3-EXT Single area 3-zone extinguishing control panel","description":"\u003cp\u003eThe Notifier NFS3-EXT is a single-area, 3-zone extinguishant releasing control panel for small to medium fixed fire-fighting installations. It is approved to EN 12094-1 (BS EN 12094-1 Class A) and complies with EN 54-2 and EN 54-4.\u003c\/p\u003e\u003cp\u003eExtinguishant release can be configured to activate from any combination of detection zone inputs, for example any two from three, as needed for ceiling void, room and floor void detection. A large LED display handles configuration and control and shows the time remaining until extinguishant release.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree detection zones as standard\u003c\/li\u003e\n\u003cli\u003eConfigurable input combinations, delay options and non-latching zone\u003c\/li\u003e\n\u003cli\u003eConfigurable extinguishant duration timer\u003c\/li\u003e\n\u003cli\u003eCountdown timer display, duplicated on up to seven remote status units\u003c\/li\u003e\n\u003cli\u003eFull remote repeater capability (NFS-10LU) and optional auxiliary I\/O board (NFS-AUX)\u003c\/li\u003e\n\u003cli\u003eExtract fan control\u003c\/li\u003e\n\u003cli\u003eAll electronics on a single, easily removable steel plate with quick-release door, allowing a back box first fix\u003c\/li\u003e\n\u003cli\u003eKnock-outs on the top and rear for cable entry\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDimensions: 310 mm (H) x 385 mm (W) x 90 mm (D)\u003c\/li\u003e\n\u003cli\u003eWeight: 5 kg (without batteries)\u003c\/li\u003e\n\u003cli\u003eSupply rating: 230 V AC +10% -15%, 50\/60 Hz, 1.6 A\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3 A total including battery charge, 28 V DC ± 2 V\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to +50 °C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eIngress protection: IP30\u003c\/li\u003e\n\u003cli\u003eStandards: EN 12094-1, EN 54-2, EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Notifier Europe","offers":[{"title":"Default Title","offer_id":56706907701621,"sku":"NFS3-EXT","price":702.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/JEM_ecb6c7de-5fad-49f2-9c05-687a6701eec4.png?v=1770373771"},{"product_id":"kentec-sigma-xt-extinguishant-control-panel-k11031m2","title":"Kentec Sigma XT Extinguishant Control Panel (K11031M2)","description":"\u003ch2\u003eKentec Sigma XT Extinguishant Control Panel (K11031M2)\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKentec Sigma XT Extinguishant Control Panel (K11031M2)\u003c\/strong\u003e is a professional \u003cstrong\u003ethree-zone, single-area extinguishing control panel\u003c\/strong\u003e designed for the control of fixed gaseous fire suppression systems. Suitable for small to medium-sized installations, the Sigma XT combines fire detection and extinguishant release control within a robust and easy-to-install surface-mounted enclosure.\u003c\/p\u003e\n\u003cp\u003eFeaturing \u003cstrong\u003ethree detection zones as standard\u003c\/strong\u003e, the K11031M2 can be configured so that any single zone or combination of zones initiates the extinguishant release sequence. This flexibility allows the system to support a wide range of suppression applications while helping installers meet specific site requirements.\u003c\/p\u003e\n\u003cp\u003eThe Sigma XT provides configurable detection and first-stage sounder delays, an adjustable extinguishant release delay and a clear countdown timer showing the time remaining before discharge. It also supports manual release operation and connection of up to seven compatible four-wire status indicators.\u003c\/p\u003e\n\u003cp\u003eDesigned and manufactured for professional life safety applications, the K11031M2 is approved to \u003cstrong\u003eEN12094-1, EN54-2 and EN54-4\u003c\/strong\u003e, providing a dependable solution for controlling gaseous fire suppression systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eGenuine Kentec Sigma XT extinguishant control panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Code: K11031M2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree detection zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-area extinguishing control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSurface mount enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAny single zone or combination of zones can be configured for release\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable first-stage sounder delays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable detection delays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable extinguishant release delay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountdown timer displays time remaining until release\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZero time delay option for manual release\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with intrinsically safe barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to seven four-wire status indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated power supply and battery charger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust steel enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproved to EN12094-1, EN54-2 and EN54-4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBrand: Kentec\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRange: Sigma XT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Code: K11031M2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Extinguishant Control Panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetection Zones: 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtinguishing Areas: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMains Supply: 230V AC, 50Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply Rating: 3A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetection Circuits: 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSounder Circuits: 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtinguishant Release Output: 21 to 28V DC, 1A maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelease Delay: Adjustable from 0 to 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelease Duration: Adjustable from 60 to 300 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Capacity: Up to 2 × 12V 7Ah sealed lead acid batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure: Mild steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP Rating: IP30\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 310 × 385 × 90mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: Approximately 6kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompliance: EN12094-1, EN54-2 and EN54-4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp\u003eThe Kentec Sigma XT K11031M2 is suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eGaseous fire suppression systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eServer and data rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical switch rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTelecommunications facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlant and machinery rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArchives and document storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial buildings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical equipment areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall to medium fixed firefighting installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the Kentec Sigma XT?\u003c\/h2\u003e\n\u003cp\u003eThe Sigma XT provides flexible detection and extinguishant release control within a compact and proven platform. Its three-zone configuration, programmable release logic and comprehensive indication make it a reliable choice for professional installers designing fixed gaseous fire suppression systems.\u003c\/p\u003e\n\u003ch2\u003eWhy Buy from JEM UK?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCompetitive prices on genuine Kentec products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpert technical advice\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast UK dispatch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrusted supplier of professional fire and life safety equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcellent customer service for installers, businesses and end users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784670359925,"sku":"K11031M2","price":558.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmaxtpanel-1.png?v=1771966601"},{"product_id":"c-tec-ep-3-zone-automatic-extinguisher-release-panel-ep203","title":"C-TEC EP 3 Zone Automatic Extinguisher Release Panel (EP203)","description":"\u003cp\u003eThe C-TEC EP203 is a three zone automatic extinguisher release panel, LPCB certified to EN 12094-1 (gas extinguishing system control) and EN54-2\/4. It works as a standard three zone conventional fire panel with extra circuitry to control the release of fire-suppressing gas, and is ideal for computer rooms, telecommunication centres, archive stores, museums and other areas housing expensive, dangerous or irreplaceable equipment.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCertified to EN12094-1 and EN54-2\/4 by the LPCB\u003c\/li\u003e\n\u003cli\u003e128 x 64 pixel display\u003c\/li\u003e\n\u003cli\u003eAny combination of activated zones can start the extinguishant release sequence\u003c\/li\u003e\n\u003cli\u003eManual release button and two keyswitches\u003c\/li\u003e\n\u003cli\u003e3 conventional sounder circuits (two 1st stage, one 2nd stage)\u003c\/li\u003e\n\u003cli\u003eSix monitored inputs, including hold and abort\u003c\/li\u003e\n\u003cli\u003eVolt-free changeover relays for fire, local fire, 1st stage, 2nd stage, extract fan and fault\u003c\/li\u003e\n\u003cli\u003eAdjustable flood times and time-stamped event log\u003c\/li\u003e\n\u003cli\u003e3A EN54-4 switch mode PSU; other electronics on a detachable metal bridge plate for easy installation\u003c\/li\u003e\n\u003cli\u003eRS485 connection for up to 8 remote status units; single gang economy status units also available\u003c\/li\u003e\n\u003cli\u003eOptional relay expansion boards and single gang hold\/abort buttons\u003c\/li\u003e\n\u003cli\u003eSystem line terminator included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZones: 3 conventional detection zones at 19-28V DC (max. 250m per circuit)\u003c\/li\u003e\n\u003cli\u003eDevices per zone: 20 detectors, or 32 detectors\/manual call points combined\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 3, max. 200mA each\u003c\/li\u003e\n\u003cli\u003eEnd-of-line resistor: 6k8Ω\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V 50\/60Hz, 810mA max.\u003c\/li\u003e\n\u003cli\u003eInternal power supply: 19V-28.5V (27V nominal)\u003c\/li\u003e\n\u003cli\u003eOutput current: 1.5A continuous, 3A peak\u003c\/li\u003e\n\u003cli\u003eBatteries: 2 x 12V 7Ah VRLA in series\u003c\/li\u003e\n\u003cli\u003eRelays: 6 (fire, local fire, extract fan, 1st stage, 2nd stage, fault), volt-free single pole changeover, max. 1A at 30V DC\u003c\/li\u003e\n\u003cli\u003eExtinguishant release output: 21-28V DC, rated 1A for 5 minutes; delay 0-60s, active 1-300s, flood 60-1800s (programmable)\u003c\/li\u003e\n\u003cli\u003eInputs: manual release, flow switch, low pressure, mode, hold, abort\u003c\/li\u003e\n\u003cli\u003eExpansion: up to 8 remote status units (2-wire RS485 + 2-wire power) and\/or up to 8 economy status units\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 439mm (W) x 276mm (H) x 70mm (D); lid 467mm (W) x 293mm (H) x 29mm (D)\u003c\/li\u003e\n\u003cli\u003eConstruction: metal back box and chassis, plastic lid; IP30\u003c\/li\u003e\n\u003cli\u003eWeight: 4.2kg (without batteries)\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C, max. 95% relative humidity\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"C-TEC","offers":[{"title":"Default Title","offer_id":56784670523765,"sku":"EP203","price":396.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/ep203-1.jpg?v=1771966604"},{"product_id":"haes-esprit-g-single-area-automatic-extinguishant-control-panel-1-2a-psu-esg-1001","title":"HAES Esprit-G Single Area Automatic Extinguishant Control Panel 1.2A PSU (ESG-1001)","description":"\u003cp\u003eThe HAES Esprit-G ESG-1001 is a single flood area automatic extinguishant release control panel. It is fully configurable for gas release scenarios, with flexible zone voting for release and programmable countdown timers to suit the exact requirements of the site.\u003c\/p\u003e\u003cp\u003eESG-1001 is the single area model with a 1.2A integral power supply (the ESG-1002 has 3.4A). It has 3 detection circuits and sounder circuits for stage 1 and stage 2 alarms, and supports a wide range of conventional detectors including Apollo, Hochiki and Nittan.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle flooding area\u003c\/li\u003e\n\u003cli\u003e3 conventional detection zones\u003c\/li\u003e\n\u003cli\u003eApproved to EN12094-1, EN54-2 and EN54-4\u003c\/li\u003e\n\u003cli\u003eFully configurable zone voting for gas release\u003c\/li\u003e\n\u003cli\u003e4 programmable sounder circuits with configurable delays\u003c\/li\u003e\n\u003cli\u003eZero time delay option for manual call points\u003c\/li\u003e\n\u003cli\u003eCompatible with IS barriers; non-latching zone input option\u003c\/li\u003e\n\u003cli\u003eLarge backlit graphical LCD display with easy-to-navigate menus\u003c\/li\u003e\n\u003cli\u003eAccess to controls by key switch or code entry\u003c\/li\u003e\n\u003cli\u003eTime and date stamped event log and alarm counter\u003c\/li\u003e\n\u003cli\u003eCompany logo can be programmed into the display\u003c\/li\u003e\n\u003cli\u003eRS485 communications for remote status units\u003c\/li\u003e\n\u003cli\u003eFire, fault and stage signal relays\u003c\/li\u003e\n\u003cli\u003eHold, abort, flow switch, manual release, mode control and pressure switch monitoring inputs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 350mm W x 300mm H x 80mm D; lid 357mm W x 310mm H x 25mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: universal switch mode PSU, 1.2A (1.2A total including battery charging)\u003c\/li\u003e\n\u003cli\u003eBattery capacity: up to 7Ah 24V\u003c\/li\u003e\n\u003cli\u003eCharger current: 700mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 400mA (21-28V DC)\u003c\/li\u003e\n\u003cli\u003eDetection zones: 3 x conventional, EOL 6k8\u003c\/li\u003e\n\u003cli\u003eExtinguishing zones: 1 x flooding\/extinguishing zone, supports metron and solenoid actuators\u003c\/li\u003e\n\u003cli\u003eRelease output: 1A continuous for solenoids; 3A for 450ms for metron actuators\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 4 x 400mA, 21-28V DC, EOL 6k8\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 6 x 1A 30V DC (fire, fault, stage 1 and 2, extract, local)\u003c\/li\u003e\n\u003cli\u003eAdditional outputs: via ESG-2005 add-on output card\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: class change, pulsing\u003c\/li\u003e\n\u003cli\u003eMonitored inputs: flow, pressure, release, hold, abort\u003c\/li\u003e\n\u003cli\u003eCountdown timers: extinguishant delay 0-60s, extinguishant duration 1-300s, flooding time 60-1800s, extract time 1-90 min, reset inhibit 0-30 min\u003c\/li\u003e\n\u003cli\u003eEvent log: 255 events, time and date stamped\u003c\/li\u003e\n\u003cli\u003eEarth fault monitoring: yes\u003c\/li\u003e\n\u003cli\u003eRemote status units: graphic display and mini versions via RS485, up to 16\u003c\/li\u003e\n\u003cli\u003eDisplay: 240 x 64 backlit graphical LCD\u003c\/li\u003e\n\u003cli\u003eManual release button: on board, under plastic release cover\u003c\/li\u003e\n\u003cli\u003eBattery size: 2 x 3.2Ah 12V VRLA (min) to 2 x 7Ah 12V VRLA (max)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784670622069,"sku":"ESG-1001","price":404.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/esg-1001-1.jpg?v=1771966606"},{"product_id":"haes-esprit-g-single-area-automatic-extinguishant-control-panel-3-4a-psu-esg-1002","title":"HAES Esprit-G Single Area Automatic Extinguishant Control Panel 3.4A PSU (ESG-1002)","description":"\u003cp\u003eThe HAES Esprit-G ESG-1002 is a single flood area automatic extinguishant release control panel with an integral 3.4A power supply. It is fully configurable for gas release scenarios, with flexible zone voting for release and programmable countdown timers to suit the site.\u003c\/p\u003e\u003cp\u003eIt has 3 conventional detection zones, supports metron and solenoid type actuators, and a large graphical display gives an easy-to-navigate menu system. It is approved to EN12094-1, EN54-2 and EN54-4.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle flooding area with 3 detection zones\u003c\/li\u003e\n\u003cli\u003eApproved to EN12094-1, EN54-2 and EN54-4\u003c\/li\u003e\n\u003cli\u003eFully configurable zone voting for gas release\u003c\/li\u003e\n\u003cli\u003e4 programmable sounder circuits with configurable delays\u003c\/li\u003e\n\u003cli\u003eZero time delay option for manual call points\u003c\/li\u003e\n\u003cli\u003eCompatible with IS barriers; non-latching zone input option\u003c\/li\u003e\n\u003cli\u003eHold, abort, flow switch, manual release, mode control and pressure switch monitoring inputs\u003c\/li\u003e\n\u003cli\u003eFire, fault and stage signal relays; 2A actuator circuit\u003c\/li\u003e\n\u003cli\u003eRS485 communications for remote status units\u003c\/li\u003e\n\u003cli\u003eAccess controls via key switch or code entry\u003c\/li\u003e\n\u003cli\u003eOnboard manual release button under plastic cover\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 350mm W x 300mm H x 80mm D; lid 357mm W x 310mm H x 25mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: universal switch mode PSU, 3.4A\u003c\/li\u003e\n\u003cli\u003eBattery capacity: up to 7Ah 24V\u003c\/li\u003e\n\u003cli\u003eCharger current: 700mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 400mA (21-28V DC)\u003c\/li\u003e\n\u003cli\u003eDetection zones: 3 x conventional\u003c\/li\u003e\n\u003cli\u003eExtinguishing zones: 1 flooding zone, metron and solenoid actuators supported\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 4 x 400mA, 21-28V DC\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 6 x 1A 30V DC (fire, fault, stage 1 and 2, extract, local)\u003c\/li\u003e\n\u003cli\u003eAdditional outputs: via ESG-2005 output card\u003c\/li\u003e\n\u003cli\u003eCountdown timers: extinguishant delay 0-60 s, extinguishant duration 1-300 s, flooding time 60-1800 s, extract time 1-90 min, reset inhibit 0-30 min\u003c\/li\u003e\n\u003cli\u003eEvent log: 255 events, time and date stamped\u003c\/li\u003e\n\u003cli\u003eEarth fault monitoring: yes\u003c\/li\u003e\n\u003cli\u003eRemote status units: graphic display and mini versions via RS485, up to 16\u003c\/li\u003e\n\u003cli\u003eDisplay: 240 x 64 backlit graphical LCD\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784671342965,"sku":"ESG-1002","price":458.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/esg-1001-1_1.jpg?v=1771966615"},{"product_id":"kentec-sigma-zxt-extinguishant-control-panel-standard-enclosure","title":"Kentec Sigma ZXT Extinguishant Control Panel (Standard Enclosure)","description":"\u003cp\u003eThe Kentec Sigma ZXT is a single area extinguishant control panel, supplied here in the standard enclosure with a 2.6A power supply (part K192311XM2). Three conventional detection zones provide the alarm stimulus for extinguishant release, and any single zone or combination of zones can be configured to contribute to release. It is approved and certified to EN12094-1, EN54-2 and EN54-4, and is fully backward compatible with existing Sigma SI status units and ancillaries.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle area extinguishing panel with 3 conventional detection zones\u003c\/li\u003e\n\u003cli\u003eDual extinguishing outputs, used together as common outputs or configured as main and reserve for two sets of cylinders\u003c\/li\u003e\n\u003cli\u003eCountdown timer shows the time remaining until release\u003c\/li\u003e\n\u003cli\u003e6 programmable volt-free changeover relays, each with one of 14 functions (such as alarm, fault, hold, abort and released)\u003c\/li\u003e\n\u003cli\u003eDynamic LCD display that changes colour with panel status\u003c\/li\u003e\n\u003cli\u003eSecure event log of 1000 events, downloadable over USB\u003c\/li\u003e\n\u003cli\u003eFully programmable from the front fascia, with 4 configurable user passcodes\u003c\/li\u003e\n\u003cli\u003eSupports up to seven Sigma ZXT four-wire status indicators (also compatible with Sigma SI status units for retrofit)\u003c\/li\u003e\n\u003cli\u003eCompatible with I.S. barriers and with Loop Explorer 2 configuration software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMains supply: 230V AC +10%\/-15% (100W max); mains fuse T2.0A 20mm 250V AC HRC\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 2.6A total including battery charge (28V ±1V)\u003c\/li\u003e\n\u003cli\u003eBatteries: two 12V 7Ah (Yuasa NP7-12) in series; charge voltage 27.6V DC nominal (temperature compensated); charge current 0.6A\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail: 0.11A; second stage alarm: 0.19A; post discharge: 0.21A\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 3; up to 32 detectors per zone (dependent on current consumption); detection EOL 6K8\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x first stage, 1 x second stage; 21 to 28V DC, fused at 500mA\u003c\/li\u003e\n\u003cli\u003eExtinguishant outputs: 1 (or 2 with S2 sounder output reconfigured); fused at 1A continuous or 3A max for 50ms\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds in 5 second steps; release duration adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fault, fire, released, mode, hold, abort): 5 to 30V DC 1A max\u003c\/li\u003e\n\u003cli\u003eStatus unit\/ancillary connection: two-wire RS485; AUX 24V output 21 to 28V DC @ 300mA (powers up to two status indicators)\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm²\u003c\/li\u003e\n\u003cli\u003eDimensions: 368 (w) x 324 (h) x 100 (d) mm\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2mm\/1.5mm mild sheet steel, epoxy powder coated, BS 00 A 05 lid and box, RAL 7016 fascia\u003c\/li\u003e\n\u003cli\u003eIP rating: IP30\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -10°C to +40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784671441269,"sku":"K192311XM2","price":504.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmazxtpanel-1.png?v=1771966617"},{"product_id":"kentec-sigma-zxt-extinguishant-control-panel-large-enclosure","title":"Kentec Sigma ZXT Extinguishant Control Panel (Large Enclosure)","description":"\u003cp\u003eThe Kentec Sigma ZXT is an extinguishant release control panel for a single protected area. It gives the controls and indications needed for an extinguishant release system. Three conventional detection zones provide the alarm signal that starts the release.\u003c\/p\u003e\u003cp\u003eThis is the large-enclosure model with a 2.6 A power supply (product code K192311XM3). It measures 368 (w) x 434 (h) x 133 (d) mm. The panel is programmed from the front fascia through password-protected user and engineer menus, or with Kentec's Loop Explorer 2 software.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle-area extinguishant control panel with three conventional detection zones; any zone or combination of zones can be set to contribute to release\u003c\/li\u003e\n\u003cli\u003eDual extinguishing outputs that can work together or as main and reserve outputs\u003c\/li\u003e\n\u003cli\u003eCountdown timer showing the time remaining until release; release delay adjustable from 0 to 60 seconds in 5-second steps\u003c\/li\u003e\n\u003cli\u003e6 programmable volt-free changeover relays, each assignable to one of fourteen functions such as Alarm, Fault, Hold, Abort or Released\u003c\/li\u003e\n\u003cli\u003eSecure event log of 1000 events, downloadable over USB with Loop Explorer 2 software\u003c\/li\u003e\n\u003cli\u003eDynamic LCD that changes colour with panel status (white normal, red fire\/released, yellow fault\/disabled\/test)\u003c\/li\u003e\n\u003cli\u003e4 configurable user passcodes; compatible with I.S. barriers\u003c\/li\u003e\n\u003cli\u003eSupports up to seven Sigma ZXT four-wire status indicators, and is backward compatible with Sigma Si status units for retrofit\u003c\/li\u003e\n\u003cli\u003eApproved and certified to EN 12094-1, EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2\/1.5 mm mild sheet steel, epoxy powder coated, IP30; fascia RAL 7016\u003c\/li\u003e\n\u003cli\u003eDimensions: 368 (w) x 434 (h) x 133 (d) mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC +10% \/ -15% (100 W max.)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 2.6 A total including battery charge (28 V +\/- 1 V); mains fuse T2.0 A 20 mm 250 V AC HRC\u003c\/li\u003e\n\u003cli\u003eBatteries: two 12 V in series - Yuasa NP7-12 (7 Ah)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.6 A; max. current from batteries: 2 A\u003c\/li\u003e\n\u003cli\u003eCurrent draw: 0.11 A mains fail \/ 0.19 A second stage alarm \/ 0.21 A post discharge\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 3 at 21 V DC nominal; max. 32 detectors per zone; EOL 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x first stage, 1 x second stage, 21 to 28 V DC at 500 mA\u003c\/li\u003e\n\u003cli\u003eExtinguishant outputs: 1 (or 2 with S2 reconfigured), fused at 1 A continuous \/ 3 A max. for 50 ms; release duration adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contacts: 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eStatus unit connection: two-wire RS485; AUX 24 V output 21 to 28 V DC at 300 mA (max. two status indicators)\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent; terminals 0.5 to 2.5 mm²\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -10°C to +40°C\u003c\/li\u003e\n\u003cli\u003eWeight: 6 to 7 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784671703413,"sku":"K192311XM3","price":542.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmazxtlargepanel-1.png?v=1771966623"},{"product_id":"kentec-sigma-zxt-extinguishant-control-panel-large-enclosure-5a-240v-psu","title":"Kentec Sigma ZXT Extinguishant Control Panel (Large Enclosure) - 5A 240V PSU","description":"\u003cp\u003eThe Kentec Sigma ZXT is an extinguishant release control panel for a single protected area. It gives the controls and indications needed for an extinguishant release system. Three conventional detection zones provide the alarm signal that starts the release.\u003c\/p\u003e\u003cp\u003eThis is the large-enclosure model with a 5.25 A power supply (product code K195311XM3). It measures 368 (w) x 434 (h) x 133 (d) mm. The panel is programmed from the front fascia through password-protected user and engineer menus, or with Kentec's Loop Explorer 2 software.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle-area extinguishant control panel with three conventional detection zones; any zone or combination of zones can be set to contribute to release\u003c\/li\u003e\n\u003cli\u003eDual extinguishing outputs that can work together or as main and reserve outputs\u003c\/li\u003e\n\u003cli\u003eCountdown timer showing the time remaining until release; release delay adjustable from 0 to 60 seconds in 5-second steps\u003c\/li\u003e\n\u003cli\u003e6 programmable volt-free changeover relays, each assignable to one of fourteen functions such as Alarm, Fault, Hold, Abort or Released\u003c\/li\u003e\n\u003cli\u003eSecure event log of 1000 events, downloadable over USB with Loop Explorer 2 software\u003c\/li\u003e\n\u003cli\u003eDynamic LCD that changes colour with panel status (white normal, red fire\/released, yellow fault\/disabled\/test)\u003c\/li\u003e\n\u003cli\u003e4 configurable user passcodes; compatible with I.S. barriers\u003c\/li\u003e\n\u003cli\u003eSupports up to seven Sigma ZXT four-wire status indicators, and is backward compatible with Sigma Si status units for retrofit\u003c\/li\u003e\n\u003cli\u003eApproved and certified to EN 12094-1, EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2\/1.5 mm mild sheet steel, epoxy powder coated, IP30; fascia RAL 7016\u003c\/li\u003e\n\u003cli\u003eDimensions: 368 (w) x 434 (h) x 133 (d) mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC +10% \/ -15% (100 W max.)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 5.25 A total including battery charge (28 V +\/- 1 V); mains fuse T3.0 A 20 mm 250 V AC HRC\u003c\/li\u003e\n\u003cli\u003eBatteries: two 12 V in series - Yuasa NP12-12 (12 Ah) or NP17-12 (17 Ah)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 1.25 A; max. current from batteries: 5.5 A\u003c\/li\u003e\n\u003cli\u003eCurrent draw: 0.14 A mains fail \/ 0.23 A second stage alarm \/ 0.26 A post discharge\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 3 at 21 V DC nominal; max. 32 detectors per zone; EOL 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 2 x first stage, 1 x second stage, 21 to 28 V DC at 500 mA\u003c\/li\u003e\n\u003cli\u003eExtinguishant outputs: 1 (or 2 with S2 reconfigured), fused at 1 A continuous \/ 3 A max. for 50 ms; release duration adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contacts: 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eStatus unit connection: two-wire RS485; AUX 24 V output 21 to 28 V DC at 300 mA (max. two status indicators)\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent; terminals 0.5 to 2.5 mm²\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -10°C to +40°C\u003c\/li\u003e\n\u003cli\u003eWeight: 6 to 7 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784671768949,"sku":"K195311XM3","price":603.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmazxtlargepanel-1_1.png?v=1771966625"},{"product_id":"kentec-sigma-xt-2-zone-single-area-extinguishing-control-panel-k21021m3","title":"Kentec Sigma XT+ 2 Zone, Single Area Extinguishing Control Panel (K21021M3)","description":"\u003cp\u003eThe Kentec Sigma XT+ K21021M3 is a multi-area extinguishant control panel with 2 conventional fire detection zones and a single extinguishant area. It combines Sigma CP conventional fire detection with Sigma XT+ extinguishing control modules, giving one integrated control solution for fixed extinguishing systems.\u003c\/p\u003e\u003cp\u003eThe detection section talks to the extinguishant control modules over a secure, two-way serial link. Each extinguishant area has its own full set of inputs and outputs and is set up through a simple programming interface.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApproved to EN 12094-1, EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as main\/reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area, plus released and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delay and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator showing the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored inputs for remote manual release, hold, mode select (door interlock), released pressure switch, low pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eSerial connection for up to 7 Sigma Si status units or ancillary boards per extinguishant area\u003c\/li\u003e\n\u003cli\u003eUp to 7 Sigma CP ancillary boards (K580) or Sigma CP sounder boards (K461) can be added on the RS485 serial bus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: K21021M3\u003c\/li\u003e\n\u003cli\u003eDetection zones: 2\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30; lid and box BS 00 A 05 grey, controls plate RAL 7047 light grey\u003c\/li\u003e\n\u003cli\u003eWeight: 8 kg\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC 50 Hz +10% \/ -15% (100 W max.); mains fuse 1.6 A\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3 A total including battery charge (28 V +\/- 2 V)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal (temperature compensated); charge current 0.7 A max.; battery fuse 3.15 A\u003c\/li\u003e\n\u003cli\u003eMax. current draw from batteries: 3 A\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54 mA per module\u003c\/li\u003e\n\u003cli\u003eAux 24 V output: fused at 500 mA (electronic fuse), one per extinguishant area\u003c\/li\u003e\n\u003cli\u003e1st and 2nd stage sounder outputs: 21 to 28 V DC, fused at 1 A (electronic fuse); EOL 10K resistor\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fault, fire, local fire, first stage, second stage, extract): 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 21 to 28 V DC; typically 20 detectors per zone (depends on type); EOL 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eExtinguishant release output: 21 to 28 V DC, fused at 1 A; EOL 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eRelease delay: adjustable 0 to 60 seconds; release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eMonitored inputs EOL: 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eStatus unit\/ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent; terminals 0.5 to 2.5 mm² solid or stranded\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784671900021,"sku":"K21021M3","price":679.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmaxt_panel.png?v=1771966628"},{"product_id":"haes-esprit-dual-area-automatic-extinguishant-control-panel-3-4a-psu-esg-1003","title":"HAES Esprit Dual Area Automatic Extinguishant Control Panel 3.4A PSU (ESG-1003)","description":"\u003cp\u003eThe HAES Esprit-G ESG-1003 is a dual flood area automatic extinguishant release control panel. It is fully configurable for gas release scenarios, with flexible zone voting for release and programmable countdown timers to suit the exact requirements of the site.\u003c\/p\u003e\u003cp\u003eThe dual area panel has 6 detection circuits and sounder circuits for stage 1 and stage 2 alarms in both flood areas, with an integral 3.4A power supply for up to 18Ah batteries. It supports a wide range of conventional detectors including Apollo, Hochiki and Nittan.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual flooding areas\u003c\/li\u003e\n\u003cli\u003e6 conventional detection zones\u003c\/li\u003e\n\u003cli\u003eApproved to EN12094-1, EN54-2 and EN54-4\u003c\/li\u003e\n\u003cli\u003eFully configurable zone voting for gas release\u003c\/li\u003e\n\u003cli\u003e6 programmable sounder circuits with configurable delays\u003c\/li\u003e\n\u003cli\u003eZero time delay option for manual call points\u003c\/li\u003e\n\u003cli\u003eCompatible with IS barriers; non-latching zone input option\u003c\/li\u003e\n\u003cli\u003eLarge backlit graphical LCD display with easy-to-navigate menus\u003c\/li\u003e\n\u003cli\u003eAccess to controls by key switch or code entry\u003c\/li\u003e\n\u003cli\u003eTime and date stamped event log and alarm counter\u003c\/li\u003e\n\u003cli\u003eCompany logo can be programmed into the display\u003c\/li\u003e\n\u003cli\u003eRS485 communications for remote status units\u003c\/li\u003e\n\u003cli\u003eFire, fault and stage signal relays\u003c\/li\u003e\n\u003cli\u003eHold, abort, flow switch, manual release, mode control and pressure switch monitoring inputs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure: 1.2mm mild steel, IP30, Interpon powder coat (colour ref MW334E)\u003c\/li\u003e\n\u003cli\u003eCable entry: 20mm knockouts in the top and rear of the cabinet\u003c\/li\u003e\n\u003cli\u003eDimensions: back box 450mm W x 385mm H x 100mm D; lid 463mm W x 394mm H x 25mm D\u003c\/li\u003e\n\u003cli\u003eMains supply: universal switch mode PSU, 3.4A (maximum load shared between outputs 3A)\u003c\/li\u003e\n\u003cli\u003eBattery capacity: up to 18Ah 24V\u003c\/li\u003e\n\u003cli\u003eCharger current: 700mA\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 400mA (21-28V DC)\u003c\/li\u003e\n\u003cli\u003eDetection zones: 6 x conventional, EOL 6k8\u003c\/li\u003e\n\u003cli\u003eExtinguishing zones: 2 x flooding\/extinguishing zone, supports metron and solenoid actuators\u003c\/li\u003e\n\u003cli\u003eRelease output: 1A continuous for solenoids; 3A for 450ms for metron actuators\u003c\/li\u003e\n\u003cli\u003eSounder circuits: 6 x 400mA, 21-28V DC, EOL 6k8\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 10 x 1A 30V DC (fire, fault, stage 1 and 2, extract, local, per area)\u003c\/li\u003e\n\u003cli\u003eAdditional outputs: via ESG-2005 add-on output card\u003c\/li\u003e\n\u003cli\u003eSwitch inputs: class change, pulsing\u003c\/li\u003e\n\u003cli\u003eMonitored inputs: flow, pressure, release, hold, abort\u003c\/li\u003e\n\u003cli\u003eCountdown timers: extinguishant delay 0-60s, extinguishant duration 1-300s, flooding time 60-1800s, extract time 1-90 min, reset inhibit 0-30 min\u003c\/li\u003e\n\u003cli\u003eEvent log: 255 events, time and date stamped\u003c\/li\u003e\n\u003cli\u003eEarth fault monitoring: yes\u003c\/li\u003e\n\u003cli\u003eRemote status units: graphic display and mini versions via RS485, up to 16\u003c\/li\u003e\n\u003cli\u003eDisplay: 240 x 64 backlit graphical LCD\u003c\/li\u003e\n\u003cli\u003eManual release buttons: 2 x on board, under plastic release covers\u003c\/li\u003e\n\u003cli\u003eStandby \/ alarm current: 184mA \/ 277mA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HAES Technologies","offers":[{"title":"Default Title","offer_id":56784671998325,"sku":"ESG-1003","price":646.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/esg-1003-1.jpg?v=1771966630"},{"product_id":"kentec-sigma-xt-4-zone-single-area-extinguishing-control-panel-k21041m3","title":"Kentec Sigma XT+ 4 Zone, Single Area Extinguishing Control Panel (K21041M3)","description":"\u003cp\u003eThe Kentec Sigma XT+ K21041M3 is a multi-area extinguishant control panel with 4 conventional fire detection zones and a single extinguishant area. It combines Sigma CP conventional fire detection with Sigma XT+ extinguishing control modules, giving one integrated control solution for fixed extinguishing systems.\u003c\/p\u003e\u003cp\u003eThe detection section talks to the extinguishant control modules over a secure, two-way serial link. Each extinguishant area has its own full set of inputs and outputs and is set up through a simple programming interface.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApproved to EN 12094-1, EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as main\/reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area, plus released and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delay and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator showing the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored inputs for remote manual release, hold, mode select (door interlock), released pressure switch, low pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eSerial connection for up to 7 Sigma Si status units or ancillary boards per extinguishant area\u003c\/li\u003e\n\u003cli\u003eUp to 7 Sigma CP ancillary boards (K580) or Sigma CP sounder boards (K461) can be added on the RS485 serial bus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: K21041M3\u003c\/li\u003e\n\u003cli\u003eDetection zones: 4\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30; lid and box BS 00 A 05 grey, controls plate RAL 7047 light grey\u003c\/li\u003e\n\u003cli\u003eWeight: 8 kg\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC 50 Hz +10% \/ -15% (100 W max.); mains fuse 1.6 A\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3 A total including battery charge (28 V +\/- 2 V)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal (temperature compensated); charge current 0.7 A max.; battery fuse 3.15 A\u003c\/li\u003e\n\u003cli\u003eMax. current draw from batteries: 3 A\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54 mA per module\u003c\/li\u003e\n\u003cli\u003eAux 24 V output: fused at 500 mA (electronic fuse), one per extinguishant area\u003c\/li\u003e\n\u003cli\u003e1st and 2nd stage sounder outputs: 21 to 28 V DC, fused at 1 A (electronic fuse); EOL 10K resistor\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fault, fire, local fire, first stage, second stage, extract): 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 21 to 28 V DC; typically 20 detectors per zone (depends on type); EOL 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eExtinguishant release output: 21 to 28 V DC, fused at 1 A; EOL 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eRelease delay: adjustable 0 to 60 seconds; release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eMonitored inputs EOL: 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eStatus unit\/ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent; terminals 0.5 to 2.5 mm² solid or stranded\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784672129397,"sku":"K21041M3","price":636.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmaxt_panel_1.png?v=1771966633"},{"product_id":"kentec-sigma-xt-8-zone-single-area-extinguishing-control-panel-k21081m3","title":"Kentec Sigma XT+ 8 Zone, Single Area Extinguishing Control Panel (K21081M3)","description":"\u003cp\u003eThe Kentec Sigma XT+ K21081M3 is a multi-area extinguishant control panel with 8 conventional fire detection zones and a single extinguishant area. It combines Sigma CP conventional fire detection with Sigma XT+ extinguishing control modules, giving one integrated control solution for fixed extinguishing systems.\u003c\/p\u003e\u003cp\u003eThe detection section talks to the extinguishant control modules over a secure, two-way serial link. Each extinguishant area has its own full set of inputs and outputs and is set up through a simple programming interface.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApproved to EN 12094-1, EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as main\/reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area, plus released and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delay and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator showing the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored inputs for remote manual release, hold, mode select (door interlock), released pressure switch, low pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eSerial connection for up to 7 Sigma Si status units or ancillary boards per extinguishant area\u003c\/li\u003e\n\u003cli\u003eUp to 7 Sigma CP ancillary boards (K580) or Sigma CP sounder boards (K461) can be added on the RS485 serial bus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: K21081M3\u003c\/li\u003e\n\u003cli\u003eDetection zones: 8\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30; lid and box BS 00 A 05 grey, controls plate RAL 7047 light grey\u003c\/li\u003e\n\u003cli\u003eWeight: 8 kg\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC 50 Hz +10% \/ -15% (100 W max.); mains fuse 1.6 A\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3 A total including battery charge (28 V +\/- 2 V)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal (temperature compensated); charge current 0.7 A max.; battery fuse 3.15 A\u003c\/li\u003e\n\u003cli\u003eMax. current draw from batteries: 3 A\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54 mA per module\u003c\/li\u003e\n\u003cli\u003eAux 24 V output: fused at 500 mA (electronic fuse), one per extinguishant area\u003c\/li\u003e\n\u003cli\u003e1st and 2nd stage sounder outputs: 21 to 28 V DC, fused at 1 A (electronic fuse); EOL 10K resistor\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fault, fire, local fire, first stage, second stage, extract): 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 21 to 28 V DC; typically 20 detectors per zone (depends on type); EOL 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eExtinguishant release output: 21 to 28 V DC, fused at 1 A; EOL 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eRelease delay: adjustable 0 to 60 seconds; release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eMonitored inputs EOL: 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eStatus unit\/ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent; terminals 0.5 to 2.5 mm² solid or stranded\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784672293237,"sku":"K21081M3","price":929.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmaxt_panel_3.png?v=1771966637"},{"product_id":"kentec-sigma-xt-4-zone-2-area-extinguishing-control-panel-k21042m3","title":"Kentec Sigma XT+ 4 Zone, 2 Area Extinguishing Control Panel (K21042M3)","description":"\u003cp\u003eThe Kentec Sigma XT+ K21042M3 is a multi-area extinguishant control panel with 4 conventional detection zones and 2 extinguishant areas. It combines Sigma CP conventional fire detection with configurable extinguishing control modules, and complies with EN 12094-1, EN 54-2 and EN 54-4.\u003c\/p\u003e\u003cp\u003eEach area has a full set of inputs and outputs. Each area can also have up to seven Sigma Si status units or ancillary relay boards connected by a simple four-core cable.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 detection zones, 2 extinguishant areas\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs per area (configurable as main\/reserve)\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs and volt-free changeover contacts per area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delay and output duration; countdown indicator in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote manual release, hold, abort, mode select (door interlock), released pressure switch and low pressure switch inputs\u003c\/li\u003e\n\u003cli\u003eRS485 serial connection for Sigma Si status units and ancillary boards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: K21042M3\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC 50 Hz +10% \/ -15% (100 W max.); fuse 1.6 A\u003c\/li\u003e\n\u003cli\u003ePower supply: 3 A total including battery charge (28 V +\/- 2 V)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal; charge current 0.7 A max.; max. draw from batteries 3 A\u003c\/li\u003e\n\u003cli\u003eSounder outputs: 21 to 28 V DC, fused at 1 A\u003c\/li\u003e\n\u003cli\u003eRelay contacts: 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eExtinguishant release output: 21 to 28 V DC, fused at 1 A; delay 0 to 60 s; duration 60 to 300 s\u003c\/li\u003e\n\u003cli\u003eDetection and monitored input EOL: 6K8 resistor; extinguishant output EOL: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent\u003c\/li\u003e\n\u003cli\u003eWeight: 8 kg (standard panel)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784672424309,"sku":"K21042M3","price":1179.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmaxt_panel_2.png?v=1771966641"},{"product_id":"kentec-sigma-xt-8-zone-2-area-extinguishing-control-panel-k21082m3","title":"Kentec Sigma XT+ 8 Zone, 2 Area Extinguishing Control Panel (K21082M3)","description":"\u003cp\u003eThe Kentec Sigma XT+ K21082M3 is a multi-area extinguishant control panel with 8 conventional fire detection zones and 2 extinguishant areas. It combines Sigma CP conventional fire detection with Sigma XT+ extinguishing control modules, giving one integrated control solution for fixed extinguishing systems.\u003c\/p\u003e\u003cp\u003eThe detection section talks to the extinguishant control modules over a secure, two-way serial link. Each extinguishant area has its own full set of inputs and outputs and is set up through a simple programming interface.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApproved to EN 12094-1, EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as main\/reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area, plus released and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delay and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator showing the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored inputs for remote manual release, hold, mode select (door interlock), released pressure switch, low pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eSerial connection for up to 7 Sigma Si status units or ancillary boards per extinguishant area\u003c\/li\u003e\n\u003cli\u003eUp to 7 Sigma CP ancillary boards (K580) or Sigma CP sounder boards (K461) can be added on the RS485 serial bus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: K21082M3\u003c\/li\u003e\n\u003cli\u003eDetection zones: 8\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 2\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30; lid and box BS 00 A 05 grey, controls plate RAL 7047 light grey\u003c\/li\u003e\n\u003cli\u003eWeight: 8 kg\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC 50 Hz +10% \/ -15% (100 W max.); mains fuse 1.6 A\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3 A total including battery charge (28 V +\/- 2 V)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal (temperature compensated); charge current 0.7 A max.; battery fuse 3.15 A\u003c\/li\u003e\n\u003cli\u003eMax. current draw from batteries: 3 A\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54 mA per module\u003c\/li\u003e\n\u003cli\u003eAux 24 V output: fused at 500 mA (electronic fuse), one per extinguishant area\u003c\/li\u003e\n\u003cli\u003e1st and 2nd stage sounder outputs: 21 to 28 V DC, fused at 1 A (electronic fuse); EOL 10K resistor\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fault, fire, local fire, first stage, second stage, extract): 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 21 to 28 V DC; typically 20 detectors per zone (depends on type); EOL 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eExtinguishant release output: 21 to 28 V DC, fused at 1 A; EOL 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eRelease delay: adjustable 0 to 60 seconds; release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eMonitored inputs EOL: 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eStatus unit\/ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent; terminals 0.5 to 2.5 mm² solid or stranded\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784672620917,"sku":"K21082M3","price":1250.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmaxt_panel_4.png?v=1771966645"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-1-loop-1-area-apollo-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 1 Loop, 1 Area (Apollo Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ A31161M3 is a multi-area, analogue addressable extinguishant release control panel with 1 loop and 1 extinguishant area, for use with Apollo protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eApollo protocol, 1 loop, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e1 extinguishant area (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: A31161M3\u003c\/li\u003e\n\u003cli\u003eProtocol: Apollo\u003c\/li\u003e\n\u003cli\u003eDetection loops: 1\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 1\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 3A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784673145205,"sku":"A31161M3","price":1340.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1.png?v=1771966649"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-1-loop-1-area-hochiki-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 1 Loop, 1 Area (Hochiki Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ H31161M3 is a multi-area, analogue addressable extinguishant release control panel with 1 loop and 1 extinguishant area, for use with Hochiki protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eHochiki protocol, 1 loop, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e1 extinguishant area (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: H31161M3\u003c\/li\u003e\n\u003cli\u003eProtocol: Hochiki\u003c\/li\u003e\n\u003cli\u003eDetection loops: 1\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 1\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 3A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784673309045,"sku":"H31161M3","price":1266.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_5.png?v=1771966652"},{"product_id":"kentec-sigma-xt-8-zone-3-area-extinguishing-control-panel-k21083m4","title":"Kentec Sigma XT+ 8 Zone, 3 Area Extinguishing Control Panel (K21083M4)","description":"\u003cp\u003eThe Kentec Sigma XT+ K21083M4 is a multi-area extinguishant control panel with 8 conventional fire detection zones and 3 extinguishant areas. It combines Sigma CP conventional fire detection with Sigma XT+ extinguishing control modules, giving one integrated control solution for fixed extinguishing systems.\u003c\/p\u003e\u003cp\u003eThe detection section talks to the extinguishant control modules over a secure, two-way serial link. Each extinguishant area has its own full set of inputs and outputs and is set up through a simple programming interface.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApproved to EN 12094-1, EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as main\/reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area, plus released and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delay and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator showing the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored inputs for remote manual release, hold, mode select (door interlock), released pressure switch, low pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eSerial connection for up to 7 Sigma Si status units or ancillary boards per extinguishant area\u003c\/li\u003e\n\u003cli\u003eUp to 7 Sigma CP ancillary boards (K580) or Sigma CP sounder boards (K461) can be added on the RS485 serial bus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: K21083M4\u003c\/li\u003e\n\u003cli\u003eDetection zones: 8\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 3\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 700 x 145 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30; lid and box BS 00 A 05 grey, controls plate RAL 7047 light grey\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC 50 Hz +10% \/ -15% (100 W max.); mains fuse 1.6 A\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 5.25 A including battery charge (28 V +\/- 2 V)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal (temperature compensated); charge current 0.7 A max.; battery fuse 3.15 A\u003c\/li\u003e\n\u003cli\u003eMax. current draw from batteries: 4 A\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54 mA per module\u003c\/li\u003e\n\u003cli\u003eAux 24 V output: fused at 500 mA (electronic fuse), one per extinguishant area\u003c\/li\u003e\n\u003cli\u003e1st and 2nd stage sounder outputs: 21 to 28 V DC, fused at 1 A (electronic fuse); EOL 10K resistor\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fault, fire, local fire, first stage, second stage, extract): 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 21 to 28 V DC; typically 20 detectors per zone (depends on type); EOL 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eExtinguishant release output: 21 to 28 V DC, fused at 1 A; EOL 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eRelease delay: adjustable 0 to 60 seconds; release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eMonitored inputs EOL: 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eStatus unit\/ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent; terminals 0.5 to 2.5 mm² solid or stranded\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784673472885,"sku":"K21083M4","price":1499.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmaxt_panel_5.png?v=1771966656"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-2-loops-1-area-apollo-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 2 Loops, 1 Area (Apollo Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ A32161M3 is a multi-area, analogue addressable extinguishant release control panel with 2 loops and 1 extinguishant area, for use with Apollo protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eApollo protocol, 2 loops, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e1 extinguishant area (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: A32161M3\u003c\/li\u003e\n\u003cli\u003eProtocol: Apollo\u003c\/li\u003e\n\u003cli\u003eDetection loops: 2\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 1\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 3A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784673571189,"sku":"A32161M3","price":1723.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_1.png?v=1771966658"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-2-loops-1-area-hochiki-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 2 Loops, 1 Area (Hochiki Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ H32161M3 is a multi-area, analogue addressable extinguishant release control panel with 2 loops and 1 extinguishant area, for use with Hochiki protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eHochiki protocol, 2 loops, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e1 extinguishant area (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: H32161M3\u003c\/li\u003e\n\u003cli\u003eProtocol: Hochiki\u003c\/li\u003e\n\u003cli\u003eDetection loops: 2\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 1\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 3A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784673669493,"sku":"H32161M3","price":1565.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_6.png?v=1771966660"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-1-loop-2-areas-apollo-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 1 Loop, 2 Areas (Apollo Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ A31162M3 is a multi-area, analogue addressable extinguishant release control panel with 1 loop and 2 extinguishant areas, for use with Apollo protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eApollo protocol, 1 loop, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e2 extinguishant areas (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: A31162M3\u003c\/li\u003e\n\u003cli\u003eProtocol: Apollo\u003c\/li\u003e\n\u003cli\u003eDetection loops: 1\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 2\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 3A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784673800565,"sku":"A31162M3","price":1486.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_2.png?v=1771966663"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-1-loop-2-areas-hochiki-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 1 Loop, 2 Areas (Hochiki Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ H31162M3 is a multi-area, analogue addressable extinguishant release control panel with 1 loop and 2 extinguishant areas, for use with Hochiki protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eHochiki protocol, 1 loop, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e2 extinguishant areas (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: H31162M3\u003c\/li\u003e\n\u003cli\u003eProtocol: Hochiki\u003c\/li\u003e\n\u003cli\u003eDetection loops: 1\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 2\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 3A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784673898869,"sku":"H31162M3","price":1590.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_7.png?v=1771966665"},{"product_id":"kentec-sigma-xt-8-zone-4-area-extinguishing-control-panel-k21084m4","title":"Kentec Sigma XT+ 8 Zone, 4 Area Extinguishing Control Panel (K21084M4)","description":"\u003cp\u003eThe Kentec Sigma XT+ K21084M4 is a multi-area extinguishant control panel with 8 conventional fire detection zones and 4 extinguishant areas. It combines Sigma CP conventional fire detection with Sigma XT+ extinguishing control modules, giving one integrated control solution for fixed extinguishing systems.\u003c\/p\u003e\u003cp\u003eThe detection section talks to the extinguishant control modules over a secure, two-way serial link. Each extinguishant area has its own full set of inputs and outputs and is set up through a simple programming interface.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApproved to EN 12094-1, EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as main\/reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area, plus released and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delay and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator showing the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored inputs for remote manual release, hold, mode select (door interlock), released pressure switch, low pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eSerial connection for up to 7 Sigma Si status units or ancillary boards per extinguishant area\u003c\/li\u003e\n\u003cli\u003eUp to 7 Sigma CP ancillary boards (K580) or Sigma CP sounder boards (K461) can be added on the RS485 serial bus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: K21084M4\u003c\/li\u003e\n\u003cli\u003eDetection zones: 8\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 4\u003c\/li\u003e\n\u003cli\u003eDimensions: 385 x 700 x 145 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: 1.2 mm mild sheet steel, epoxy powder coated, IP30; lid and box BS 00 A 05 grey, controls plate RAL 7047 light grey\u003c\/li\u003e\n\u003cli\u003eMains supply: 230 V AC 50 Hz +10% \/ -15% (100 W max.); mains fuse 1.6 A\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 5.25 A including battery charge (28 V +\/- 2 V)\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6 V DC nominal (temperature compensated); charge current 0.7 A max.; battery fuse 3.15 A\u003c\/li\u003e\n\u003cli\u003eMax. current draw from batteries: 4 A\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54 mA per module\u003c\/li\u003e\n\u003cli\u003eAux 24 V output: fused at 500 mA (electronic fuse), one per extinguishant area\u003c\/li\u003e\n\u003cli\u003e1st and 2nd stage sounder outputs: 21 to 28 V DC, fused at 1 A (electronic fuse); EOL 10K resistor\u003c\/li\u003e\n\u003cli\u003eRelay contacts (fault, fire, local fire, first stage, second stage, extract): 5 to 30 V DC, 1 A max. each\u003c\/li\u003e\n\u003cli\u003eDetection circuits: 21 to 28 V DC; typically 20 detectors per zone (depends on type); EOL 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eExtinguishant release output: 21 to 28 V DC, fused at 1 A; EOL 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eRelease delay: adjustable 0 to 60 seconds; release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eMonitored inputs EOL: 6K8 resistor\u003c\/li\u003e\n\u003cli\u003eStatus unit\/ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent; terminals 0.5 to 2.5 mm² solid or stranded\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784673997173,"sku":"K21084M4","price":1921.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/sigmaxt_panel_6.png?v=1771966667"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-2-loops-2-areas-apollo-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 2 Loops, 2 Areas (Apollo Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ A32162M3 is a multi-area, analogue addressable extinguishant release control panel with 2 loops and 2 extinguishant areas, for use with Apollo protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eApollo protocol, 2 loops, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e2 extinguishant areas (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: A32162M3\u003c\/li\u003e\n\u003cli\u003eProtocol: Apollo\u003c\/li\u003e\n\u003cli\u003eDetection loops: 2\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 2\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 3A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784674128245,"sku":"A32162M3","price":1834.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_3.png?v=1771966671"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-2-loops-2-areas-hochiki-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 2 Loops, 2 Areas (Hochiki Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ H32162M3 is a multi-area, analogue addressable extinguishant release control panel with 2 loops and 2 extinguishant areas, for use with Hochiki protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eHochiki protocol, 2 loops, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e2 extinguishant areas (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: H32162M3\u003c\/li\u003e\n\u003cli\u003eProtocol: Hochiki\u003c\/li\u003e\n\u003cli\u003eDetection loops: 2\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 2\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 520 x 110 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 3A total including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 3A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784674619765,"sku":"H32162M3","price":1963.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_8.png?v=1771966673"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-2-loops-4-areas-apollo-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 2 Loops, 4 Areas (Apollo Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ A32164M4 is a multi-area, analogue addressable extinguishant release control panel with 2 loops and 4 extinguishant areas, for use with Apollo protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eApollo protocol, 2 loops, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e4 extinguishant areas (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: A32164M4\u003c\/li\u003e\n\u003cli\u003eProtocol: Apollo\u003c\/li\u003e\n\u003cli\u003eDetection loops: 2\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 4\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 700 x 145 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 4A including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 4A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784674718069,"sku":"A32164M4","price":2578.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_4.png?v=1771966675"},{"product_id":"kentec-syncro-xt-extinguishing-control-panel-2-loops-4-areas-hochiki-protocol","title":"Kentec Syncro XT+ Extinguishing Control Panel - 2 Loops, 4 Areas (Hochiki Protocol)","description":"\u003cp\u003eThe Kentec Syncro XT+ H32164M4 is a multi-area, analogue addressable extinguishant release control panel with 2 loops and 4 extinguishant areas, for use with Hochiki protocol addressable detection devices. It combines addressable fire detection and extinguishant release control in one panel.\u003c\/p\u003e\u003cp\u003eSyncro XT+ panels comply with EN12094-1. Up to 16 zones of addressable detection are available, so every detector can contribute to the extinguishant release decision.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComplies with EN12094-1\u003c\/li\u003e\n\u003cli\u003eHochiki protocol, 2 loops, 16 detection zones\u003c\/li\u003e\n\u003cli\u003e4 extinguishant areas (the Syncro XT+ range offers up to 4 areas)\u003c\/li\u003e\n\u003cli\u003eDual extinguishant outputs for each area, configurable as Main\/Reserve\u003c\/li\u003e\n\u003cli\u003eFirst and second stage sounder outputs for each area\u003c\/li\u003e\n\u003cli\u003eFirst and second stage volt-free changeover contacts for each area\u003c\/li\u003e\n\u003cli\u003eReleased and fault volt-free contacts per area\u003c\/li\u003e\n\u003cli\u003eProgrammable extinguishant delays and output duration\u003c\/li\u003e\n\u003cli\u003eCountdown indicator shows the time until release in seconds\u003c\/li\u003e\n\u003cli\u003eMode select and manual release controls per area\u003c\/li\u003e\n\u003cli\u003eMonitored remote inputs: manual release, hold, mode select (door interlock), released pressure switch and abort\u003c\/li\u003e\n\u003cli\u003eUp to 7 serially connected Sigma Si status units or ancillary relay boards (K588) per area, via a simple 4-core cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProduct code: H32164M4\u003c\/li\u003e\n\u003cli\u003eProtocol: Hochiki\u003c\/li\u003e\n\u003cli\u003eDetection loops: 2\u003c\/li\u003e\n\u003cli\u003eDetection zones: 16\u003c\/li\u003e\n\u003cli\u003eExtinguishant areas: 4\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 385 x 700 x 145 mm\u003c\/li\u003e\n\u003cli\u003eMains supply: 230V AC, 50Hz +10% \/ -15% (100 W maximum)\u003c\/li\u003e\n\u003cli\u003eMains supply fuse: 1.6A (F1.6A L250V)\u003c\/li\u003e\n\u003cli\u003ePower supply rating: 4A including battery charge, 28V +\/- 2V\u003c\/li\u003e\n\u003cli\u003eBattery charge voltage: 27.6V DC nominal (temperature compensated)\u003c\/li\u003e\n\u003cli\u003eBattery charge current: 0.7A maximum\u003c\/li\u003e\n\u003cli\u003eBattery fuse: 20mm, 3.15A glass\u003c\/li\u003e\n\u003cli\u003eCurrent draw in mains fail condition: 54mA per extinguishing module\u003c\/li\u003e\n\u003cli\u003eMaximum current draw from batteries: 4A\u003c\/li\u003e\n\u003cli\u003eExtinguishant release delay: adjustable 0 to 60 seconds (+\/- 10%)\u003c\/li\u003e\n\u003cli\u003eExtinguishant release duration: adjustable 60 to 300 seconds\u003c\/li\u003e\n\u003cli\u003eRelay contact ratings (fault, fire, local fire, first stage, second stage, extract): 5 to 30V DC, 1A maximum each\u003c\/li\u003e\n\u003cli\u003eMonitored input end of line: 6K8 +\/- 5% ½ W resistor; sounder circuit end of line: 10K +\/- 5% ¼ W resistor; extinguishant output end of line: 1N4004 diode\u003c\/li\u003e\n\u003cli\u003eStatus unit \/ ancillary board connection: two-wire RS485 (EIA-485)\u003c\/li\u003e\n\u003cli\u003eStatus unit power output: 21 to 28V DC, fused at 500mA with electronic fuse\u003c\/li\u003e\n\u003cli\u003eTerminal capacity: 0.5mm² to 2.5mm² solid or stranded wire\u003c\/li\u003e\n\u003cli\u003eCabling: FP200 or equivalent (max capacitance 1uF, max inductance 1mH)\u003c\/li\u003e\n\u003cli\u003eFinish: epoxy powder coated; lid and box BS 00 A 05 grey (fine texture); controls plate and labels RAL 7047 light grey (satin)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":56784674881909,"sku":"H32164M4","price":2758.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/syncroxtpanel-1_9.png?v=1771966678"},{"product_id":"comelit-extinguishing-panel-3-detection-zone","title":"Comelit Extinguishing Panel 3 Detection Zone","description":"\u003cp\u003eConventional fire extinguishing system control panel with 3 wired zones (2 fire extinguishing and 1 alarm) designed for use in combination with active fire extinguishing systems. Can be combined with events log module 46LEP000 (optional)\u003c\/p\u003e","brand":"Comelit-PAC","offers":[{"title":"Default Title","offer_id":57305406013813,"sku":"46EST003","price":385.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/4b5c9d98-3005-4bba-8be2-8268c09ffe99.png?v=1792404204"},{"product_id":"kentec-syncro-xt-1-loop-apollo-protocol-3-area-extinguishant-control-panel","title":"Kentec Syncro XT+ 1 Loop Apollo Protocol 3 Area Extinguishant Control Panel","description":"\u003cp\u003eSyncro 1 loop addressable control module + 3 single area extinguishing control module Space to add additional extinguishing modules Detection and Extinguishing controls and status indicators Dual action manual extinguishing release control Auto\/Manual keyswitch Integral 5.25 Amp power supply 230V AC input Space for 2 x 12V 12Ah SLA batteries Surface Mount M4 enclosure 385mm (W) x 700mm (H) x 145mm (D)\u003c\/p\u003e","brand":"Kentec Electronics","offers":[{"title":"Default Title","offer_id":57305430229365,"sku":"A31163M4","price":2234.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/8d2ac7cf-5c0c-4ccb-8490-9b475f32f7c6.png?v=1781868347"}],"url":"https:\/\/jemsystems.co.uk\/collections\/extinguishant-control-panels.oembed","provider":"JEM Systems UK","version":"1.0","type":"link"}