{"title":"Fire Alarm Panels","description":"\u003cp\u003eFire alarm panels for installers: conventional, two-wire, addressable and wireless control panels from 1 zone to 8 loops, plus repeaters and spares – all genuine, brand new and factory sealed, with fast, tracked UK delivery.\u003c\/p\u003e\n\u003ch2\u003eConventional vs addressable fire alarm panels\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eConventional fire alarm panels\u003c\/strong\u003e divide the building into zones, each wired as a separate radial circuit. In an alarm the panel shows which zone has operated, not which device. They suit smaller premises such as shops and small offices. \u003cstrong\u003eTwo-wire\u003c\/strong\u003e panels are a conventional variant in which detectors and sounders share the same pair of cables on each zone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAddressable fire alarm panels\u003c\/strong\u003e connect detectors, call points and sounders on one or more loops. Every device has its own address, so the panel shows exactly which device has triggered an alarm or fault – suited to offices, hotels and larger buildings.\u003c\/p\u003e\n\u003ch2\u003eFire alarm panels we stock\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 zone fire alarm panels\u003c\/strong\u003e – the C-TEC \u003ca href=\"\/products\/c-tec-cfp-4-zone-conventional-fire-alarm-panel-cfp704-5\"\u003eCFP704-4\u003c\/a\u003e, \u003ca href=\"\/products\/advanced-qz-4-quickzone-4-zone-panel\"\u003eAdvanced QZ-4 QuickZone\u003c\/a\u003e, \u003ca href=\"\/products\/kidde-4-zone-conventional-fire-alarm-control-panel-nc-pf4-1\"\u003eKidde NC-PF4\u003c\/a\u003e, \u003ca href=\"\/products\/fike-twinflexpro-4-zone-fire-alarm-panel-505-0004\"\u003eFike TwinflexPro² 4 zone\u003c\/a\u003e and \u003ca href=\"\/products\/global-fire-orion-4-zone-conventional-fire-panel-orion-4\"\u003eGlobal Fire ORION-4\u003c\/a\u003e. Other conventional panels run from 1 to 32 zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-wire panels\u003c\/strong\u003e – \u003ca href=\"\/products\/c-tec-cfp-alarmsense-4-zone-2-wire-fire-alarm-panel-cfp704-2\"\u003eC-TEC CFP AlarmSense\u003c\/a\u003e, \u003ca href=\"\/products\/zeta-infinity-id2-4-zone-intelligent-2-wire-fire-alarm-panel-id2-4\"\u003eZeta Infinity ID2\u003c\/a\u003e and Fike TwinflexPro².\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressable fire alarm panels\u003c\/strong\u003e – 1 to 8 loop panels: \u003ca href=\"\/products\/advanced-mx-5101-1-loop-fire-panel-small-apo-hoch\"\u003eAdvanced MxPro 5\u003c\/a\u003e and \u003ca href=\"\/products\/advanced-go1-go1-fire-alarm-panel-grey-apollo-hochiki-126-127-addresses\"\u003eGo1+\u003c\/a\u003e, \u003ca href=\"\/products\/kentec-syncro-as-2-loop-analogue-addressable-control-panel-no-keyswitch-apollo-protocol\"\u003eKentec Syncro AS\u003c\/a\u003e, \u003ca href=\"\/products\/c-tec-xfp-2-loop-32-zone-addressable-fire-panel-xp95-discovery-protocol-xfp502-x\"\u003eC-TEC XFP\u003c\/a\u003e and ZFP, \u003ca href=\"\/products\/notifier-europe-020-727\"\u003eNotifier ID3000\u003c\/a\u003e, \u003ca href=\"\/products\/morley-ias-ma-2000-01-max-series-2-loop-system-sensor-with-7-touch-display\"\u003eMorley-IAS MAX\u003c\/a\u003e and \u003ca href=\"\/products\/fireclass-557-200-949\"\u003eFireClass FC702S\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless panels\u003c\/strong\u003e – \u003ca href=\"\/products\/ems-firecell-syncro-as-1-loop-16-zone-addressable-fire-panel-fc-a80161m2\"\u003eEMS FireCell\u003c\/a\u003e and \u003ca href=\"\/products\/electro-detectors-zerio-plus-8-zone-wireless-fire-control-panel-eda-z5008\"\u003eZerio Plus\u003c\/a\u003e. See \u003ca href=\"\/collections\/wireless-fire-detection\"\u003ewireless fire detection\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeaters, extinguishant panels and spares\u003c\/strong\u003e – \u003ca href=\"\/products\/c-tec-xfp-16-zone-addressable-repeater-panel-all-protocols-xfp510-16\"\u003eC-TEC XFP510-16\u003c\/a\u003e and \u003ca href=\"\/products\/c-tec-cfp-8-zone-repeater-panel-cfp760-2\"\u003eCFP760\u003c\/a\u003e repeaters, \u003ca href=\"\/products\/kentec-sigma-xt-4-zone-single-area-extinguishing-control-panel-k21041m3\"\u003eKentec Sigma XT+\u003c\/a\u003e extinguishing panels, plus keys, doors, PCBs and loop cards. \u003ca href=\"\/collections\/disabled-refuge-systems\"\u003eDisabled refuge systems\u003c\/a\u003e, \u003ca href=\"\/collections\/batteries\"\u003ebatteries\u003c\/a\u003e and \u003ca href=\"\/collections\/power-supplies\"\u003epower supplies\u003c\/a\u003e are listed separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow many zones or loops do you need?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZones:\u003c\/strong\u003e BS 5839-1 says a detection zone should cover no more than one storey (unless the building's total floor area is under 300 m²) and no more than 2,000 m², with a search distance of no more than 60 m. Stairwells and lift shafts are separate zones. Allow spare capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoops:\u003c\/strong\u003e the number of devices per loop depends on the protocol – the single-loop Advanced Go1+ takes 126\/127 addresses (Apollo\/Hochiki), the Go1V+ 240 (Argus). Short-circuit isolators should limit a single fault to 2,000 m² and one storey, and two simultaneous faults to 10,000 m².\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e addressable devices must use the panel's protocol, e.g. Apollo XP95\/Discovery, Hochiki ESP, Argus Vega or C-TEC CAST.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e panels are covered by EN 54-2 and power supplies by EN 54-4; zones and loops should be designed by a competent person to BS 5839-1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShop fire alarm panels by brand\u003c\/h2\u003e\n\u003cp\u003eJEM Systems UK is an authorised distributor of Advanced, Notifier, Morley-IAS, Kidde and FireClass. Browse \u003ca href=\"\/collections\/advanced-premium-fire-alarm-safety-solutions\"\u003eAdvanced\u003c\/a\u003e, \u003ca href=\"\/collections\/c-tec\"\u003eC-TEC\u003c\/a\u003e, \u003ca href=\"\/collections\/kentec\"\u003eKentec\u003c\/a\u003e, \u003ca href=\"\/collections\/notifier\"\u003eNotifier\u003c\/a\u003e, \u003ca href=\"\/collections\/morley-ias\"\u003eMorley-IAS\u003c\/a\u003e, \u003ca href=\"\/collections\/fireclass\"\u003eFireClass\u003c\/a\u003e, \u003ca href=\"\/collections\/kidde-commercial\"\u003eKidde\u003c\/a\u003e, \u003ca href=\"\/collections\/fike\"\u003eFike\u003c\/a\u003e, \u003ca href=\"\/collections\/haes\"\u003eHAES\u003c\/a\u003e, \u003ca href=\"\/collections\/zeta\"\u003eZeta\u003c\/a\u003e, \u003ca href=\"\/collections\/global-fire-equipment\"\u003eGlobal Fire\u003c\/a\u003e, \u003ca href=\"\/collections\/gst\"\u003eGST\u003c\/a\u003e, \u003ca href=\"\/collections\/nittan\"\u003eNittan\u003c\/a\u003e and \u003ca href=\"\/collections\/ems\"\u003eEMS\u003c\/a\u003e. Complete the system with \u003ca href=\"\/collections\/manual-call-points\"\u003emanual call points\u003c\/a\u003e, \u003ca href=\"\/collections\/fire-alarm-sounders-beacons\"\u003esounders and beacons\u003c\/a\u003e, \u003ca href=\"\/collections\/smoke-detectors\"\u003esmoke\u003c\/a\u003e and \u003ca href=\"\/collections\/heat-detectors\"\u003eheat detectors\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eFire alarm panel FAQs\u003c\/h2\u003e\n\u003ch3\u003eWhat does a fire alarm panel do?\u003c\/h3\u003e\n\u003cp\u003eThe fire alarm control panel, or control and indicating equipment (CIE), monitors detectors and call points, operates sounders and beacons, shows where an alarm or fault is and runs on standby batteries if mains power fails.\u003c\/p\u003e\n\u003ch3\u003eWhat size fire alarm panel do I need?\u003c\/h3\u003e\n\u003cp\u003eMatch it to the zones or devices on the design. A 2 or 4 zone panel often suits a small single-storey building; larger or multi-storey sites usually suit an addressable panel.\u003c\/p\u003e\n\u003ch3\u003eCan an electrician install a fire alarm panel?\u003c\/h3\u003e\n\u003cp\u003eIt should be installed by a competent person working to BS 5839-1, with wiring to BS 7671.\u003c\/p\u003e","products":[{"product_id":"morley-ias-ma-2000-01-max-series-2-loop-system-sensor-with-7-touch-display","title":"Morley-IAS MA-2000-01 MAX Series, 2-Loop System Sensor with 7\" Touch Display","description":"\u003ch2\u003eMorley-IAS MA-2000-01 MAX Series, 2-Loop System Sensor with 7\" Touch Display, 120W 24V Power Supply\u003c\/h2\u003e\n\u003cp\u003eMorley-IAS Max two loop (networkable) For System Sensor \u0026amp; Apollo protocol\u003c\/p\u003e","brand":"Morley-IAS","offers":[{"title":"Default Title","offer_id":55105976140149,"sku":"MA-2000-01","price":864.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/morley-ias-default-title-morley-ias-ma-2000-01-max-series-2-loop-system-sensor-with-7-touch-display-ma-2000-01-65685188116853.jpg?v=1766067864"},{"product_id":"morley-ias-ma-8000-01-max-series-4-loop-system-sensor-with-7-touch-display","title":"Morley-IAS MA-8000-01 MAX Series, 4-Loop System Sensor with 7\" Touch Display","description":"\u003ch2\u003eMorley-IAS MA-8000-01 MAX Series, 4-Loop System Sensor with 7\" Touch Display, 200W 24V Power Supply For System Sensor \u0026amp; Apollo Protocol\u003c\/h2\u003e","brand":"Morley-IAS","offers":[{"title":"Default Title","offer_id":55105976303989,"sku":"MA-8000-01","price":1388.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/morley-ias-default-title-morley-ias-ma-8000-01-max-series-4-loop-system-sensor-with-7-touch-display-ma-8000-01-65684908310901.jpg?v=1766067865"},{"product_id":"morley-ias-pl-1000-plus-addressable-fire-alarm-panel","title":"Morley-IAS PL-1000 Plus Addressable Fire Alarm Panel","description":"\u003cp\u003eThe Morley-IAS Plus PL-1000 is a compact, single-loop analogue addressable fire alarm control panel that is quick to install and configure. It uses Honeywell's Advanced (AP) protocol, which speeds up alarm detection and gives the installer as much information as possible.\u003c\/p\u003e\u003cp\u003eThe panel can be expanded to two loops with the optional PL-LIB01 loop card, and each loop supports 159 detectors and 159 input\/output modules. A 4.3 inch colour touch screen lets you configure the whole system from the panel itself.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4.3 inch (480 x 272 pixel) backlit colour touch screen and backlit membrane buttons\u003c\/li\u003e\n\u003cli\u003eSingle loop, expandable to two loops with the optional PL-LIB01 loop module\u003c\/li\u003e\n\u003cli\u003e159 detectors and 159 input\/output modules per loop\u003c\/li\u003e\n\u003cli\u003eHoneywell Advanced (AP) protocol\u003c\/li\u003e\n\u003cli\u003eMultiple language options\u003c\/li\u003e\n\u003cli\u003eColour event indication tab system\u003c\/li\u003e\n\u003cli\u003eSimple dot matrix cause and effect rule builder\u003c\/li\u003e\n\u003cli\u003e16 virtual zonal LED indicators on screen\u003c\/li\u003e\n\u003cli\u003eCertified to EN 54-2 and EN 54-4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMains supply: 100-240 V AC +\/-15%, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePower consumption: 65 W max.\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 7 Ah or 12 Ah (batteries not included)\u003c\/li\u003e\n\u003cli\u003e24 V DC output: 500 mA max.\u003c\/li\u003e\n\u003cli\u003eRelay outputs: 1 fault (NO\/NC), 1 alarm (NO\/NC)\u003c\/li\u003e\n\u003cli\u003eProtection class: IP30\u003c\/li\u003e\n\u003cli\u003eColour: RAL 9002\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 356 x 379 x 120 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 1.76 kg\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C\u003c\/li\u003e\n\u003cli\u003eHumidity: 5% to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Morley-IAS","offers":[{"title":"Default Title","offer_id":55105977287029,"sku":"PL-1000","price":388.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/morley-ias-default-title-morley-ias-pl-1000-plus-addressable-fire-alarm-panel-pl-1000-65685636252021.jpg?v=1766067856"},{"product_id":"ziton-zp2-af2-fb-s-addressable-fire-panel-repeater-small-cab-2-loop","title":"Ziton ZP2-AF2-FB-S Addressable Fire Panel Repeater - Small Cab (2 Loop)","description":"\u003ch2\u003eAddressable Fire Panel Repeater - Fire Brigade Controls - Small Cabinet - 2 Loop\u003c\/h2\u003e\n\u003cp\u003eThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility, the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness, manufactured in metal, special plastics and easy electronics removal, it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.\u003c\/p\u003e\n\u003cp\u003eWith high power loop addressable detection, a full line of easily configured option cards and modules, as well as USB and Ethernet® connectivity, these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.\u003c\/p\u003e\n\u003cp\u003eThe fire panels supplied in local language, with user interface with fire brigade and fire protection controls, with 1 loop that supports up to 254 devices each (127 addresses) in 512 zones, have standard 2 supervised sounder\/fire-routing outputs, which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs, working in pair and dedicated to common fire and fault conditions, as well as 2 user configurable inputs for monitoring and control are available\u003c\/p\u003e","brand":"Ziton","offers":[{"title":"Default Title","offer_id":55106980118901,"sku":"ZP2-AF2-FB-S","price":746.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/ziton-default-title-ziton-zp2-af2-fb-s-addressable-fire-panel-repeater-small-cab-2-loop-zp2-af2-fb-s-64040267317621.png?v=1766067988"},{"product_id":"gst-gst108a","title":"GST GST108A Conventional Fire Alarm Control Panel","description":"\u003ch2\u003eGST GST108A Conventional Fire Alarm Control Panel\u003c\/h2\u003e\n\u003cp\u003eThe GST108A is compatible with GST conventional detectors, manual call points and sounders. The panel is easy to install and operate. Control functions are enabled by key switch whilst programming functions are enabled by key switch in combination with an internal switch.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8 Detection zones\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEach zone can support up to 15 conventional detectors or 32 manual call points, to a combined total of 32 devices.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eShort and open circuit reporting of detection zones, sounder and alarm outputs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpace provided inside the CIE cabinet for 2 SLA batteries for standby support\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy enable\/disable operation for zones, sounder and alarm outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GST","offers":[{"title":"Default Title","offer_id":55106992177525,"sku":"GST108A","price":190.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/gst108a-1.png?v=1768144528"},{"product_id":"nittan-evolution-1-single-loop-control-panel-with-touch-screen-display","title":"Nittan Evolution 1 Single Loop Control Panel Touch Screen Display (F12-83101)","description":"\u003cp\u003eThe Nittan evolution 1 (part no. F12-83101) is a single-loop analogue addressable fire alarm control panel with a 4.3-inch colour touch screen. It is fully compatible with the Nittan Evolution range of detection and alarm devices and is certified to EN 54-2 and EN 54-4.\u003c\/p\u003e\u003cp\u003eCause and effect can be set up on the panel itself or with the PC configuration tool and then downloaded. Panels can be networked, up to 16 in total, without extra hardware. The ABS enclosure has a fully removable front cover to make cabling and termination easier.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4.3-inch colour touch screen with an intuitive menu structure\u003c\/li\u003e\n\u003cli\u003eUp to 254 devices on the loop and 254 zones\u003c\/li\u003e\n\u003cli\u003eFull cause-and-effect programming at the panel or with the PC configuration tool\u003c\/li\u003e\n\u003cli\u003eNetwork up to 16 panels\u003c\/li\u003e\n\u003cli\u003e2 x configurable RS485 ports\u003c\/li\u003e\n\u003cli\u003eUp to 8 password-protected users\u003c\/li\u003e\n\u003cli\u003eSwitch-mode power supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMains supply: 230 V AC (+10% \/ -15%), 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOperating current: 1.0 A max.\u003c\/li\u003e\n\u003cli\u003eSystem voltage: 24 V DC nominal\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max.; loop length up to 2 km\u003c\/li\u003e\n\u003cli\u003eFire and fault relays: 1 x each, 230 V AC at 1 A\u003c\/li\u003e\n\u003cli\u003eEnclosure rating: IP30 (indoor use)\u003c\/li\u003e\n\u003cli\u003eConventional sounder outputs: 2 x 100 mA at 24 V DC\u003c\/li\u003e\n\u003cli\u003eCharger voltage: 27.6 V DC\u003c\/li\u003e\n\u003cli\u003eBatteries: up to 2 x 7.0 Ah 12 V DC sealed lead acid\u003c\/li\u003e\n\u003cli\u003eEnclosure: W 370 x H 311 x D 113 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 2.7 kg without batteries (7.35 kg with batteries)\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-2:1997 + A1:2006; EN 54-4:1997 + A1:2002 + A2:2006\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNote: Nittan advises that panels with firmware 22.0.0 or newer cannot be networked with panels running firmware 21.09.05.20 or older.\u003c\/p\u003e","brand":"Nittan","offers":[{"title":"Default Title","offer_id":55107177906549,"sku":"F12-83101","price":330.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/NittanEvolution1SingleLoopControlPanelwithTouchScreenDisplay.png?v=1765896128"},{"product_id":"fireclass-508-032-044","title":"FireClass 508.032.044 Spare Motherboard for FC-503 3 Loop Panel","description":"\u003cp\u003eThe FireClass 508.032.044 is the spare motherboard for the FireClass FC503 3-loop addressable fire alarm control panel, listed by the manufacturer as an accessory in the FC503 ordering information. The FC503 is an auto-addressing panel with 3-in-1 loops supporting up to 250 addressable devices and 128 zones.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine FireClass spare motherboard for the FC503 panel\u003c\/li\u003e\n\u003cli\u003eFC503 panel: up to 800 mA loop current dynamically shared across 3 circuits in 1 loop\u003c\/li\u003e\n\u003cli\u003eFC503 panel: auto mapping with Intelli-Zone, walk test, 4,000-event log and loop break location\u003c\/li\u003e\n\u003cli\u003eFC503 panel: on-board PSTN communicator; event transmission through PSTN and IP\u003c\/li\u003e\n\u003cli\u003eFC503 panel: up to 8 repeaters and up to 7 FC500 series panel clients\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOrder number: 508.032.044\u003c\/li\u003e\n\u003cli\u003eManufacturer description: Spare Motherboard for FC-503 3 Loop FireClass Panel\u003c\/li\u003e\n\u003cli\u003eCompatible panel: FireClass FC503 (557.200.725), 3-loop panel, 250 points\u003c\/li\u003e\n\u003cli\u003eFC503 supply voltage: 230 V AC 50 Hz (-15\/+10%)\u003c\/li\u003e\n\u003cli\u003eFC503 aux output rated voltage: 27.6 V DC\u003c\/li\u003e\n\u003cli\u003eFC503 loop power: 800 mA\u003c\/li\u003e\n\u003cli\u003eFC503 maximum battery size: 17 Ah\u003c\/li\u003e\n\u003cli\u003eFC503 operating temperature: -5°C to 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149566886261,"sku":"508.032.044","price":327.85,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/20241223_114004.jpg?v=1782726503"},{"product_id":"fireclass-508-032-045","title":"FireClass FC506 Board Spare Motherboard for FC-506 6 Loop Panel (508.032.045)","description":"\u003cp\u003eThe FireClass 508.032.045 is the spare motherboard for the FireClass FC506 6-loop addressable fire control panel (557.200.726).\u003c\/p\u003e\u003cp\u003eThe FC506 is an auto-addressing panel with \"6 in 2\" loops: three circuits in each of two loops, supporting up to 500 addressable devices and 256 zones. Up to 800 mA is dynamically shared across the three circuits of each loop. The panel is programmed from its backlit 4 x 40-character LCD and front controls or with FireClass PC software.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireClass spare motherboard for the FC506\u003c\/li\u003e\n\u003cli\u003eFC506 panel features: auto mapping with Intelli-Zone, loop break location, walk test and 4000-event log\u003c\/li\u003e\n\u003cli\u003eOn-board PSTN communicator; GSM\/GPRS as an external module; optional IP board\u003c\/li\u003e\n\u003cli\u003eDual-role USB interface (host\/device); up to 2 installers and 8 users\u003c\/li\u003e\n\u003cli\u003eUp to 8 repeaters and up to 7 FC500-series panel clients\u003c\/li\u003e\n\u003cli\u003eAutomatic drift compensation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOrder number: 508.032.045 (spare motherboard for FC506)\u003c\/li\u003e\n\u003cli\u003eFC506 capacity: 6 circuits in 2 loops, up to 500 addressable devices, 256 zones\u003c\/li\u003e\n\u003cli\u003eLoop power: 800 mA\u003c\/li\u003e\n\u003cli\u003eSupply voltage (panel): 230 V AC 50 Hz -15\/+10%; input current 1.5 A\u003c\/li\u003e\n\u003cli\u003eAux output rated voltage: 27.6 V DC\u003c\/li\u003e\n\u003cli\u003eMax. battery size (panel): 17 Ah\u003c\/li\u003e\n\u003cli\u003ePanel dimensions (H x W x D): 493 x 429 x 124 mm\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to 40°C; humidity up to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149567345013,"sku":"508.032.045","price":398.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/20250225_102738.jpg?v=1782467193"},{"product_id":"fireclass-508-032-730-essential-2-zone-panel","title":"FireClass 508.032.730 Essential 2 Zone Panel","description":"\u003ch2\u003eFireClass 508.032.730 Essential 2 Zone Panel\u003c\/h2\u003e\n\u003cp\u003eThe Fireclass Essential Panel range is an EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants.\u003c\/p\u003e\n\u003cp\u003eThe panels can support up to 128 devices with a maximum of 32 devices on each zone.\u003c\/p\u003e\n\u003cp\u003eThe panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch3\u003eThe panel UI has the following features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e18 LEDs on the 2 Zone Panel and 22 LEDs on the 4 Zone Panel\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOne piezo buzzer for audible indication\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEight push buttons for user inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePlease note: For full details on all the supported devices, refer to the EN 54-13 certificate.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149567443317,"sku":"508.032.730","price":122.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/508-032-730.jpg?v=1769635953"},{"product_id":"fireclass-508-032-731-essential-4-zone-panel","title":"FireClass 508.032.731 Essential 4 Zone Panel","description":"\u003ch2\u003eFireClass 508.032.731 Essential 4 Zone Panel\u003c\/h2\u003e\n\u003cp\u003eThe Fireclass Essential Panel range is an EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants.\u003c\/p\u003e\n\u003cp\u003eThe panels can support up to 128 devices with a maximum of 32 devices on each zone.\u003c\/p\u003e\n\u003cp\u003eThe panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch3\u003eThe panel UI has the following features:\u003c\/h3\u003e\n\u003cp\u003e18 LEDs on the 2 Zone Panel and 22 LEDs on the 4 Zone Panel\u003cbr\u003eOne piezo buzzer for audible indication\u003cbr\u003eEight push buttons for user inputs\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModern and aesthetic design\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePlease note: For full details on all the supported devices, refer to the EN 54-13 certificate.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149567902069,"sku":"508.032.731","price":134.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/20241223_112214_c4a4ecad-4407-4997-a924-983ed0b28350.jpg?v=1782725646"},{"product_id":"fireclass-fc602s-two-loop-addressable-fire-panel-557-200-650","title":"FireClass 557.200.650 FC602S Two Loop Addressable Fire Panel","description":"\u003cp\u003eFireClass FC602S Two Loop Addressable Fire Alarm Control Panel 557.200.650 The FireClass FC602S Two Loop Addressable Fire Alarm Control Panel (SKU: 557.200.650) is a compact, networkable fire alarm control panel designed for commercial and industrial fire detection systems. Featuring a shallow enclosure, intuitive colour LCD display and support for up to 250 addressable devices, it delivers reliable performance while simplifying installation, commissioning and day-to-day operation. Part of the trusted FireClass FC600 Series, the FC602S is built around the highly resilient FireClass loop protocol, offering dependable communication even in electrically noisy environments. The proven platform is shared with the FireClass FC700 range, providing outstanding reliability and flexibility for a wide variety of fire protection applications.\u003c\/p\u003e\n\u003ch3\u003eComponents \u0026amp; features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFireClass\u003c\/li\u003e\n  \u003cli\u003eFC602S addressable fire alarm control panel\u003c\/li\u003e\n  \u003cli\u003eManufacturer\u003c\/li\u003e\n  \u003cli\u003eSKU: 557.200.650 Supports two standard-power loops or one high-power loop\u003c\/li\u003e\n  \u003cli\u003eMaximum capacity of 250 addressable devices per panel\u003c\/li\u003e\n  \u003cli\u003eNetworkable architecture for larger fire alarm systems\u003c\/li\u003e\n  \u003cli\u003eHigh-resolution colour\u003c\/li\u003e\n  \u003cli\u003eLCD display for clear system status\u003c\/li\u003e\n  \u003cli\u003e32 dedicated zonal\u003c\/li\u003e\n  \u003cli\u003eLED indicators\u003c\/li\u003e\n  \u003cli\u003eCompact shallow housing for easier installation\u003c\/li\u003e\n  \u003cli\u003eSupports batteries up to 17Ah\u003c\/li\u003e\n  \u003cli\u003eBuilt on the proven\u003c\/li\u003e\n  \u003cli\u003eFC600 and FC700 hardware platform\u003c\/li\u003e\n  \u003cli\u003eHighly resistant to electrical interference and false alarm sources\u003c\/li\u003e\n  \u003cli\u003eDesigned for\u003c\/li\u003e\n  \u003cli\u003eReliable Fire\u003c\/li\u003e\n  \u003cli\u003eDetection The FC602S provides dependable operation using the advanced\u003c\/li\u003e\n  \u003cli\u003eCommercial\u003c\/li\u003e\n  \u003cli\u003eApplications\u003c\/li\u003e\n  \u003cli\u003eSuitable for offices, schools, healthcare facilities, retail premises, hotels, warehouses and other commercial buildings, the FireClass\u003c\/li\u003e\n  \u003cli\u003eFC602S offers a scalable solution that can expand alongside your fire detection requirements. Why\u003c\/li\u003e\n  \u003cli\u003eBuy from JEM UK? Competitive pricing on genuine\u003c\/li\u003e\n  \u003cli\u003eFireClass products\u003c\/li\u003e\n  \u003cli\u003eExpert technical support before and after purchase Fast\u003c\/li\u003e\n  \u003cli\u003eUK dispatch on stocked items\u003c\/li\u003e\n  \u003cli\u003eTrusted supplier of professional fire alarm equipment\u003c\/li\u003e\n  \u003cli\u003eDedicated customer service for installers and end users\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149648314741,"sku":"557.200.650","price":802.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/fireclass-default-title-fireclass-557-200-650-fc602s-two-loop-addressable-fire-panel-557-200-650-64081900208501.png?v=1766067448"},{"product_id":"fireclass-557-200-651-fc604s-four-loop-addressable-fire-panel","title":"FireClass 557.200.651 FC604S Four Loop Addressable Fire Panel","description":"\u003ch2\u003eFC604S 2-4 Loop FireClass Panel Shallow\u003c\/h2\u003e\n\u003cp\u003eThe FC604S is a four loop FireClass networkable panel with a shallow housing. This panel can have four standard-power loops or two high-power loops with each panel having a maximum of 500 addresses. It features a colour LCD display with 32 zonal LEDs, and has a maximum capacity of 17 Ah batteries.\u003c\/p\u003e\n\u003cp\u003eThe FC600 FireClass range is a powerful fire detection and alarm system that uses the robust FireClass loop protocol at its heart. The FireClass loop protocol was originally designed for operation in the most hostile of environments, therefore the system is highly resilient to external factors such as electrical noise, including interference from electrical signals from other devices, and sources of false alarm. The FC600 FireClass range uses the same hardware and software platform already well-known from the FC700 FireClass panel range.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149648675189,"sku":"557.200.651","price":981.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/fireclass-default-title-fireclass-557-200-651-fc604s-four-loop-addressable-fire-panel-557-200-651-64081892999541.png?v=1766067446"},{"product_id":"fireclass-557-200-719-fc501-l-triple-circuit-single-loop-panel-with-1-5a-psu","title":"FireClass 557.200.719 FC501-L Triple Circuit Single Loop Panel with 1.5A PSU","description":"\u003ch2\u003eFireClass 557.200.719 FC501-L Triple Circuit Single Loop Panel Icons - 1,5A PSU\u003c\/h2\u003e\n\u003cp\u003eFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use, the FC501 is an “out of the box” panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.\u003c\/p\u003e\n\u003cp\u003eAuto Addressing, Intelli-Zone, On line Help function, USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the instal­lation and configuration of the FC501 in just a few simple steps.\u003c\/p\u003e\n\u003cp\u003eThis 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones, according to the physical loop they are connected to, the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149651100021,"sku":"557.200.719","price":355.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/20250225_093506_2.jpg?v=1769533792"},{"product_id":"fireclass-557-200-949","title":"FireClass 557.200.949 FC702S 2 Loop Panel","description":"\u003cp\u003eThe FireClass FC702S (order number 557.200.949) is a 1-2 loop addressable fire control panel in a compact, shallow enclosure. It has a fully programmable 8.4-inch TFT colour touch-screen user interface with context-sensitive help and on-screen instructions, and it can be used with or without gloves.\u003c\/p\u003e\u003cp\u003eThe panel supports 250 addresses in total. Its addressable loop can be connected as one high power (HP) loop or as two shared power (SP) loops, so you can give all the power and 250 addresses to one loop or share them across two. FC702S panels can be networked together. The panel is certified to EN 54-2 and EN 54-4.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8.4-inch TFT colour touch-screen, multilingual user interface\u003c\/li\u003e\n\u003cli\u003eTouch-sensitive status LEDs with instant access to detailed event information\u003c\/li\u003e\n\u003cli\u003eUser-configurable on-screen site maps and programmable graphic quiescent display\u003c\/li\u003e\n\u003cli\u003eComprehensive point management and disable functions\u003c\/li\u003e\n\u003cli\u003e10,000-event log with dynamic filters\u003c\/li\u003e\n\u003cli\u003eKeyless log-on using RFID tags that identify and log user actions\u003c\/li\u003e\n\u003cli\u003eFlexible single or dual hardware loop configuration (1 HP or 2 SP loops)\u003c\/li\u003e\n\u003cli\u003eCompact shallow housing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOrder number: 557.200.949 (FC702S)\u003c\/li\u003e\n\u003cli\u003eLoops: 1 HP or 2 SP; up to 250 addresses per loop, 250 in total\u003c\/li\u003e\n\u003cli\u003eZonal LEDs: 16; zones supported: 240\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 480 x 410 x 140 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 9.7 kg (excluding batteries)\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 17 Ah\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230 V AC 50\/60 Hz; input current 1.6 A\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5°C to +40°C; storage -20°C to +70°C; 90% RH non-condensing\u003c\/li\u003e\n\u003cli\u003eIP rating: IP30\u003c\/li\u003e\n\u003cli\u003eColour: RAL 7035 back box and door; RAL 7016 user interface surround\u003c\/li\u003e\n\u003cli\u003eEMC: EN 50130-4, EN 61000-6-3\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2, EN 54-4 (DoP-2018-4263; 2831-CPR-F2668; 0832-UKCA-CPR-F0388)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149655097717,"sku":"557.200.949","price":871.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/20250102_142556.jpg?v=1782723801"},{"product_id":"fireclass-557-200-951-fc708d-4-8-loop-touchscreen-fire-alarm-control-panel","title":"FireClass 557.200.951 FC708D 4-8 Loop Touchscreen Fire Alarm Control Panel","description":"\u003ch2\u003eFireClass 557.200.951 FC708D 4-8 Loop Touchscreen Fire Alarm Control Panel\u003c\/h2\u003e\n\u003cp\u003eThe FireClass range of fire alarm control panels provide a great deal of flexibility in terms of hardware configuration, scalability and feature set. They are easy to operate, easy to install, easy to service and provide the system designer with a wide range of practical engineering solutions. Remote connectivity and backwards compatibility make it a future proof investment with long term support and reduced life time cost.\u003c\/p\u003e\n\u003cp\u003eThe eight loop addressable panel from FireClass is a highly featured digital addressable fire alarm system with an advanced TFT colour touch-screen user interface that is ergonomically engineered specifically for fire alarm control. Operation of the touch screen is possible with or without gloves and provides easy-to-use, intuitive user controls including keyless log-on using RFID cards.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eErgonomic Icon Display - simple to operate user interface eliminates operator errors\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTouch sensitive status LEDs provide event summary information - instant access to detailed event information\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eContext sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser configurable on screen site maps - no need for additional site plans\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgrammable graphic quiescent display - opportunity for customer branding\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eComprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSelectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eKeyless log-on using RFID tags – identifies and logs user actions\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlexible single or dual hardware loop configurations - optimise loop power and address capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntegral slot card cage – easily expanded with a number of slot card options?\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":55149655720309,"sku":"557.200.951","price":1354.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/fireclass-control-panels-default-title-fireclass-557-200-951-fc708d-4-8-loop-touchscreen-fire-alarm-control-panel-557-200-951-64082164482421.jpg?v=1766067442"},{"product_id":"edwards-27193-26-fire-alarm-control-panel-component","title":"Edwards 27193-26 White 2-Gang Surface Mount Box","description":"\u003cp\u003eThe Edwards 27193-26 is a 2-gang surface mount box in bright white from the Edwards 27193 series, a heavy-duty general-purpose utility box for surface mounting fire alarm devices. Typical uses include Signature Series modules, manual call points\/pull stations, end-of-line resistors and CO2 or Halon discharge stations. The white version is easy to finish to match the decor on site, and Edwards also lists it as related equipment for its Signature Series signal modules.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHeavy-duty one-piece 16 gauge cold rolled steel construction\u003c\/li\u003e\n\u003cli\u003eDurable baked enamel finish\u003c\/li\u003e\n\u003cli\u003ePre-drilled and tapped #6-32 device mounting holes\u003c\/li\u003e\n\u003cli\u003eCombination 1\/2 inch and 3\/4 inch conduit knockouts on the top, bottom and rear\u003c\/li\u003e\n\u003cli\u003eMounting holes in the back of the box for screw fixing\u003c\/li\u003e\n\u003cli\u003eGrounding provision\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModel: 27193-26\u003c\/li\u003e\n\u003cli\u003eSize: 2-gang\u003c\/li\u003e\n\u003cli\u003eColour: bright white\u003c\/li\u003e\n\u003cli\u003eMaterial: 16 gauge cold rolled steel\u003c\/li\u003e\n\u003cli\u003eFinish: baked enamel\u003c\/li\u003e\n\u003cli\u003eKnockouts: combination 1\/2 in and 3\/4 in (top, bottom and rear)\u003c\/li\u003e\n\u003cli\u003eDevice mounting: #6-32 tapped holes\u003c\/li\u003e\n\u003cli\u003eShipping weight: 0.8 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":55788347326837,"sku":"27193-26","price":16.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/edwards-fire-alarms-default-title-edwards-27193-26-fire-alarm-control-panel-component-27193-26-65381797822837.webp?v=1766067374"},{"product_id":"advanced-mx-5808-ft-2-8-loop-fire-panel-c-w-8-loop-cards","title":"Advanced MX-5808\/FT 2-8 Loop Fire Panel c\/w 8 Loop cards","description":"\u003cp\u003eThe Advanced MX-5808\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 8 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 8 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (8 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332002361717,"sku":"MX-5808\/FT","price":5152.22,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5808-ft-2-8-loop-fire-panel-c-w-8-loop-cards-mx-5808-ft-66749786227061.webp?v=1766067393"},{"product_id":"advanced-mx-5808a-ft-2-8-loop-fire-panel-c-w-8-loop-cards","title":"Advanced MX-5808A\/FT 2-8 Loop Fire Panel c\/w 8 Loop cards","description":"\u003cp\u003eThe Advanced MX-5808A\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 8 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 8 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (8 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332002460021,"sku":"MX-5808A\/FT","price":5152.22,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5808a-ft-2-8-loop-fire-panel-c-w-8-loop-cards-mx-5808a-ft-66749786620277.webp?v=1766068012"},{"product_id":"advanced-mx-5808v-ft-2-8-loop-fire-panel-c-w-8-loop-cards","title":"Advanced MX-5808V\/FT 2-8 Loop Fire Panel c\/w 8 Loop cards","description":"\u003cp\u003eThe Advanced MX-5808V\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 8 loop driver cards for Argus Vega devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 8 x MXP-568 loop driver cards (Argus Vega)\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Argus Vega\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (8 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Argus Vega: up to 240 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332002918773,"sku":"MX-5808V\/FT","price":5152.22,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5808v-ft-2-8-loop-fire-panel-c-w-8-loop-cards-mx-5808v-ft-66749787046261.webp?v=1766068013"},{"product_id":"advanced-mx-5808n-ft-2-8-loop-fire-panel-c-w-8-loop-cards","title":"Advanced MX-5808N\/FT 2-8 Loop Fire Panel c\/w 8 Loop cards","description":"\u003cp\u003eThe Advanced MX-5808N\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 8 loop driver cards for Nittan Evolution devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 8 x MXP-567 loop driver cards (Nittan Evolution)\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Nittan Evolution\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (8 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Nittan Evolution: up to 249 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332003344757,"sku":"MX-5808N\/FT","price":5152.22,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5808n-ft-2-8-loop-fire-panel-c-w-8-loop-cards-mx-5808n-ft-66749787668853.webp?v=1766068016"},{"product_id":"advanced-mx-5807-ft-2-8-loop-fire-panel-c-w-7-loop-cards","title":"Advanced MX-5807\/FT 2-8 Loop Fire Panel c\/w 7 Loop cards","description":"\u003cp\u003eThe Advanced MX-5807\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 7 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 7 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (7 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332003443061,"sku":"MX-5807\/FT","price":5000.44,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5807-ft-2-8-loop-fire-panel-c-w-7-loop-cards-mx-5807-ft-66749787930997.webp?v=1766068013"},{"product_id":"advanced-mx-5807a-ft-2-8-loop-fire-panel-c-w-7-loop-cards","title":"Advanced MX-5807A\/FT 2-8 Loop Fire Panel c\/w 7 Loop cards","description":"\u003cp\u003eThe Advanced MX-5807A\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 7 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 7 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (7 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332003508597,"sku":"MX-5807A\/FT","price":5000.44,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5807a-ft-2-8-loop-fire-panel-c-w-7-loop-cards-mx-5807a-ft-66749788258677.webp?v=1766068015"},{"product_id":"advanced-mx-5807v-ft-2-8-loop-fire-panel-c-w-7-loop-cards","title":"Advanced MX-5807V\/FT 2-8 Loop Fire Panel c\/w 7 Loop cards","description":"\u003cp\u003eThe Advanced MX-5807V\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 7 loop driver cards for Argus Vega devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 7 x MXP-568 loop driver cards (Argus Vega)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Argus Vega\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (7 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Argus Vega: up to 240 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332003606901,"sku":"MX-5807V\/FT","price":5000.44,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5807v-ft-2-8-loop-fire-panel-c-w-7-loop-cards-mx-5807v-ft-66749788586357.webp?v=1766068014"},{"product_id":"advanced-mx-5807n-ft-2-8-loop-fire-panel-c-w-7-loop-cards","title":"Advanced MX-5807N\/FT 2-8 Loop Fire Panel c\/w 7 Loop cards","description":"\u003cp\u003eThe Advanced MX-5807N\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 7 loop driver cards for Nittan Evolution devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 7 x MXP-567 loop driver cards (Nittan Evolution)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-567 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Nittan Evolution\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (7 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Nittan Evolution: up to 249 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332003639669,"sku":"MX-5807N\/FT","price":5000.44,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5807n-ft-2-8-loop-fire-panel-c-w-7-loop-cards-mx-5807n-ft-66749788946805.webp?v=1766068012"},{"product_id":"advanced-mx-5806-ft-2-8-loop-fire-panel-c-w-6-loop-cards","title":"Advanced MX-5806\/FT 2-8 Loop Fire Panel c\/w 6 Loop cards","description":"\u003cp\u003eThe Advanced MX-5806\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 6 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 6 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (6 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332003705205,"sku":"MX-5806\/FT","price":4847.57,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5806-ft-2-8-loop-fire-panel-c-w-6-loop-cards-mx-5806-ft-66749789241717.webp?v=1766068016"},{"product_id":"advanced-mx-5806a-ft-2-8-loop-fire-panel-c-w-6-loop-cards","title":"Advanced MX-5806A\/FT 2-8 Loop Fire Panel c\/w 6 Loop cards","description":"\u003cp\u003eThe Advanced MX-5806A\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 6 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 6 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (6 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332003869045,"sku":"MX-5806A\/FT","price":4847.57,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5806a-ft-2-8-loop-fire-panel-c-w-6-loop-cards-mx-5806a-ft-66749789798773.webp?v=1766068013"},{"product_id":"advanced-mx-5806v-ft-2-8-loop-fire-panel-c-w-6-loop-cards","title":"Advanced MX-5806V\/FT 2-8 Loop Fire Panel c\/w 6 Loop cards","description":"\u003cp\u003eThe Advanced MX-5806V\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 6 loop driver cards for Argus Vega devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 6 x MXP-568 loop driver cards (Argus Vega)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Argus Vega\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (6 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Argus Vega: up to 240 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332003901813,"sku":"MX-5806V\/FT","price":4847.57,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5806v-ft-2-8-loop-fire-panel-c-w-6-loop-cards-mx-5806v-ft-66749790093685.webp?v=1766068016"},{"product_id":"advanced-mx-5806n-ft-2-8-loop-fire-panel-c-w-6-loop-cards","title":"Advanced MX-5806N\/FT 2-8 Loop Fire Panel c\/w 6 Loop cards","description":"\u003cp\u003eThe Advanced MX-5806N\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 6 loop driver cards for Nittan Evolution devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 6 x MXP-567 loop driver cards (Nittan Evolution)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-567 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Nittan Evolution\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (6 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Nittan Evolution: up to 249 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004000117,"sku":"MX-5806N\/FT","price":4847.57,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5806n-ft-2-8-loop-fire-panel-c-w-6-loop-cards-mx-5806n-ft-66749790585205.webp?v=1766068014"},{"product_id":"advanced-mx-5805-ft-2-8-loop-fire-panel-c-w-5-loop-cards","title":"Advanced MX-5805\/FT 2-8 Loop Fire Panel c\/w 5 Loop cards","description":"\u003cp\u003eThe Advanced MX-5805\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 5 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 5 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (5 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004098421,"sku":"MX-5805\/FT","price":4694.68,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5805-ft-2-8-loop-fire-panel-c-w-5-loop-cards-mx-5805-ft-66749791043957.webp?v=1766068016"},{"product_id":"advanced-mx-5805a-ft-2-8-loop-fire-panel-c-w-5-loop-cards","title":"Advanced MX-5805A\/FT 2-8 Loop Fire Panel c\/w 5 Loop cards","description":"\u003cp\u003eThe Advanced MX-5805A\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 5 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 5 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (5 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004426101,"sku":"MX-5805A\/FT","price":4694.68,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5805a-ft-2-8-loop-fire-panel-c-w-5-loop-cards-mx-5805a-ft-66749791273333.webp?v=1766068010"},{"product_id":"advanced-mx-5805v-ft-2-8-loop-fire-panel-c-w-5-loop-cards","title":"Advanced MX-5805V\/FT 2-8 Loop Fire Panel c\/w 5 Loop cards","description":"\u003cp\u003eThe Advanced MX-5805V\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 5 loop driver cards for Argus Vega devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 5 x MXP-568 loop driver cards (Argus Vega)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Argus Vega\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (5 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Argus Vega: up to 240 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004491637,"sku":"MX-5805V\/FT","price":4694.68,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5805v-ft-2-8-loop-fire-panel-c-w-5-loop-cards-mx-5805v-ft-66749791535477.webp?v=1766068011"},{"product_id":"advanced-mx-5805n-ft-2-8-loop-fire-panel-c-w-5-loop-cards","title":"Advanced MX-5805N\/FT 2-8 Loop Fire Panel c\/w 5 Loop cards","description":"\u003cp\u003eThe Advanced MX-5805N\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 5 loop driver cards for Nittan Evolution devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 5 x MXP-567 loop driver cards (Nittan Evolution)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-567 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Nittan Evolution\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (5 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Nittan Evolution: up to 249 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004557173,"sku":"MX-5805N\/FT","price":4694.68,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5805n-ft-2-8-loop-fire-panel-c-w-5-loop-cards-mx-5805n-ft-66749791830389.webp?v=1766068012"},{"product_id":"advanced-mx-5808-2-8-loop-fire-panel-c-w-8-loop-cards","title":"Advanced MX-5808 2-8 Loop Fire Panel c\/w 8 Loop cards","description":"\u003cp\u003eThe Advanced MX-5808 is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 8 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 8 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (8 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004622709,"sku":"MX-5808","price":5452.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5802-1_9.jpg?v=1771961089"},{"product_id":"advanced-mx-5808a-2-8-loop-fire-panel-c-w-8-loop-cards","title":"Advanced MX-5808A 2-8 Loop Fire Panel c\/w 8 Loop cards","description":"\u003cp\u003eThe Advanced MX-5808A is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 8 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 8 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (8 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004721013,"sku":"MX-5808A","price":4612.1,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5808a-2-8-loop-fire-panel-c-w-8-loop-cards-mx-5808a-66749792485749.webp?v=1766068012"},{"product_id":"advanced-mx-5808v-2-8-loop-fire-panel-c-w-8-loop-cards","title":"Advanced MX-5808V 2-8 Loop Fire Panel c\/w 8 Loop cards","description":"\u003cp\u003eThe Advanced MX-5808V is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 8 loop driver cards for Argus Vega devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 8 x MXP-568 loop driver cards (Argus Vega)\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Argus Vega\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (8 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Argus Vega: up to 240 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004786549,"sku":"MX-5808V","price":4612.1,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5808v-2-8-loop-fire-panel-c-w-8-loop-cards-mx-5808v-66749792747893.webp?v=1766068012"},{"product_id":"advanced-mx-5808n-2-8-loop-fire-panel-c-w-8-loop-cards","title":"Advanced MX-5808N 2-8 Loop Fire Panel c\/w 8 Loop cards","description":"\u003cp\u003eThe Advanced MX-5808N is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 8 loop driver cards for Nittan Evolution devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 8 x MXP-567 loop driver cards (Nittan Evolution)\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Nittan Evolution\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (8 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Nittan Evolution: up to 249 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332004983157,"sku":"MX-5808N","price":4612.1,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5808n-2-8-loop-fire-panel-c-w-8-loop-cards-mx-5808n-66749793304949.webp?v=1766068010"},{"product_id":"advanced-mx-5804-ft-2-8-loop-fire-panel-c-w-4-loop-cards","title":"Advanced MX-5804\/FT 2-8 Loop Fire Panel c\/w 4 Loop cards","description":"\u003cp\u003eThe Advanced MX-5804\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 4 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 4 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (4 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005015925,"sku":"MX-5804\/FT","price":4541.81,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5804-ft-2-8-loop-fire-panel-c-w-4-loop-cards-mx-5804-ft-66749793698165.webp?v=1766068010"},{"product_id":"advanced-mx-5804a-ft-2-8-loop-fire-panel-c-w-4-loop-cards","title":"Advanced MX-5804A\/FT 2-8 Loop Fire Panel c\/w 4 Loop cards","description":"\u003cp\u003eThe Advanced MX-5804A\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 4 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 4 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (4 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005081461,"sku":"MX-5804A\/FT","price":4541.81,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5804a-ft-2-8-loop-fire-panel-c-w-4-loop-cards-mx-5804a-ft-66749793993077.webp?v=1766068014"},{"product_id":"advanced-mx-5804v-ft-2-8-loop-fire-panel-c-w-4-loop-cards","title":"Advanced MX-5804V\/FT 2-8 Loop Fire Panel c\/w 4 Loop cards","description":"\u003cp\u003eThe Advanced MX-5804V\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 4 loop driver cards for Argus Vega devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 4 x MXP-568 loop driver cards (Argus Vega)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Argus Vega\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (4 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Argus Vega: up to 240 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005146997,"sku":"MX-5804V\/FT","price":4541.81,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5804v-ft-2-8-loop-fire-panel-c-w-4-loop-cards-mx-5804v-ft-66749794320757.webp?v=1766068012"},{"product_id":"advanced-mx-5804n-ft-2-8-loop-fire-panel-c-w-4-loop-cards","title":"Advanced MX-5804N\/FT 2-8 Loop Fire Panel c\/w 4 Loop cards","description":"\u003cp\u003eThe Advanced MX-5804N\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 4 loop driver cards for Nittan Evolution devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 4 x MXP-567 loop driver cards (Nittan Evolution)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-567 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Nittan Evolution\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (4 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Nittan Evolution: up to 249 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005212533,"sku":"MX-5804N\/FT","price":4541.81,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5804n-ft-2-8-loop-fire-panel-c-w-4-loop-cards-mx-5804n-ft-66749794648437.webp?v=1766068015"},{"product_id":"advanced-mx-5807-2-8-loop-fire-panel-c-w-7-loop-cards","title":"Advanced MX-5807 2-8 Loop Fire Panel c\/w 7 Loop cards","description":"\u003cp\u003eThe Advanced MX-5807 is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 7 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 7 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (7 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005343605,"sku":"MX-5807","price":5271.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5802-1_8.jpg?v=1771961088"},{"product_id":"advanced-mx-5807a-2-8-loop-fire-panel-c-w-7-loop-cards","title":"Advanced MX-5807A 2-8 Loop Fire Panel c\/w 7 Loop cards","description":"\u003cp\u003eThe Advanced MX-5807A is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 7 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 7 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (7 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005474677,"sku":"MX-5807A","price":4459.22,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5807a-2-8-loop-fire-panel-c-w-7-loop-cards-mx-5807a-66749796057461.webp?v=1766068009"},{"product_id":"advanced-mx-5807v-2-8-loop-fire-panel-c-w-7-loop-cards","title":"Advanced MX-5807V 2-8 Loop Fire Panel c\/w 7 Loop cards","description":"\u003cp\u003eThe Advanced MX-5807V is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 7 loop driver cards for Argus Vega devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 7 x MXP-568 loop driver cards (Argus Vega)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Argus Vega\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (7 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Argus Vega: up to 240 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005540213,"sku":"MX-5807V","price":4459.22,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5807v-2-8-loop-fire-panel-c-w-7-loop-cards-mx-5807v-66749796712821.webp?v=1766068007"},{"product_id":"advanced-mx-5807n-2-8-loop-fire-panel-c-w-7-loop-cards","title":"Advanced MX-5807N 2-8 Loop Fire Panel c\/w 7 Loop cards","description":"\u003cp\u003eThe Advanced MX-5807N is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 7 loop driver cards for Nittan Evolution devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 7 x MXP-567 loop driver cards (Nittan Evolution)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-567 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Nittan Evolution\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (7 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Nittan Evolution: up to 249 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005605749,"sku":"MX-5807N","price":4459.22,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5807n-2-8-loop-fire-panel-c-w-7-loop-cards-mx-5807n-66749797106037.webp?v=1766068012"},{"product_id":"advanced-mx-5803-ft-2-8-loop-fire-panel-c-w-3-loop-cards","title":"Advanced MX-5803\/FT 2-8 Loop Fire Panel c\/w 3 Loop cards","description":"\u003cp\u003eThe Advanced MX-5803\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 3 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 3 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (3 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005671285,"sku":"MX-5803\/FT","price":4388.93,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5803-ft-2-8-loop-fire-panel-c-w-3-loop-cards-mx-5803-ft-66749797564789.webp?v=1766068007"},{"product_id":"advanced-mx-5803a-ft-2-8-loop-fire-panel-c-w-3-loop-cards","title":"Advanced MX-5803A\/FT 2-8 Loop Fire Panel c\/w 3 Loop cards","description":"\u003cp\u003eThe Advanced MX-5803A\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 3 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 3 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (3 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005769589,"sku":"MX-5803A\/FT","price":4388.93,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5803a-ft-2-8-loop-fire-panel-c-w-3-loop-cards-mx-5803a-ft-66749798056309.webp?v=1766068007"},{"product_id":"advanced-mx-5803v-ft-2-8-loop-fire-panel-c-w-3-loop-cards","title":"Advanced MX-5803V\/FT 2-8 Loop Fire Panel c\/w 3 Loop cards","description":"\u003cp\u003eThe Advanced MX-5803V\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 3 loop driver cards for Argus Vega devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 3 x MXP-568 loop driver cards (Argus Vega)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Argus Vega\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (3 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Argus Vega: up to 240 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005867893,"sku":"MX-5803V\/FT","price":4388.93,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5803v-ft-2-8-loop-fire-panel-c-w-3-loop-cards-mx-5803v-ft-66749798285685.webp?v=1766068009"},{"product_id":"advanced-mx-5803n-ft-2-8-loop-fire-panel-c-w-3-loop-cards","title":"Advanced MX-5803N\/FT 2-8 Loop Fire Panel c\/w 3 Loop cards","description":"\u003cp\u003eThe Advanced MX-5803N\/FT is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 3 loop driver cards for Nittan Evolution devices. This is the fault-tolerant network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 3 x MXP-567 loop driver cards (Nittan Evolution)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-567 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eFault-tolerant network (\/FT) panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Nittan Evolution\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (3 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Nittan Evolution: up to 249 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332005966197,"sku":"MX-5803N\/FT","price":4388.93,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5803n-ft-2-8-loop-fire-panel-c-w-3-loop-cards-mx-5803n-ft-66749798580597.webp?v=1766068010"},{"product_id":"advanced-mx-5806-2-8-loop-fire-panel-c-w-6-loop-cards","title":"Advanced MX-5806 2-8 Loop Fire Panel c\/w 6 Loop cards","description":"\u003cp\u003eThe Advanced MX-5806 is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 6 loop driver cards for Apollo (XP95 \/ Discovery) and Hochiki ESP devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 6 x MXP-568 loop driver cards (Apollo (XP95 \/ Discovery) and Hochiki ESP)\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo (XP95 \/ Discovery) and Hochiki ESP\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (6 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo XP95 \/ Discovery: up to 126 detectors\/call points per loop; Hochiki ESP: up to 127 per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332006162805,"sku":"MX-5806","price":5090.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/mx-5802-1_7.jpg?v=1771961086"},{"product_id":"advanced-mx-5806a-2-8-loop-fire-panel-c-w-6-loop-cards","title":"Advanced MX-5806A 2-8 Loop Fire Panel c\/w 6 Loop cards","description":"\u003cp\u003eThe Advanced MX-5806A is an MxPro 5 series analogue addressable fire alarm control panel, fully expandable from 2 to 8 loops and supplied in this configuration with 6 loop driver cards for Apollo Soteria (CoreProtocol) devices. This is the standard network version of the panel, housed in a 750 x 450 x 190 mm steel enclosure.\u003c\/p\u003e\u003cp\u003eSuitable for a wide range of sites from small buildings to large, complex multi-area systems, the panel combines dual flash-based processors with a high-contrast graphical display, 8 on-board sounder circuits and advanced peer-to-peer networking with other MxPro 5 and MxPro 4 panels. The network can be configured in a fault-tolerant loop or radial format.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupplied with 6 x MXP-568 loop driver cards (Apollo Soteria (CoreProtocol))\u003c\/li\u003e\n\u003cli\u003eExpandable to 8 loops: add one MXP-568 loop driver card per additional loop\u003c\/li\u003e\n\u003cli\u003eStandard network panel variant\u003c\/li\u003e\n\u003cli\u003e8 x on-board programmable sounder circuits\u003c\/li\u003e\n\u003cli\u003eUp to 400 fire zones across 8 loops, 2000 zones when networked\u003c\/li\u003e\n\u003cli\u003eHigh-resolution, white backlit 240 x 64 graphical LCD with tactile alphanumeric keypad for simple select-and-click operation\u003c\/li\u003e\n\u003cli\u003eDual flash-based microprocessors with on-board real-time clock and trace diagnostics\u003c\/li\u003e\n\u003cli\u003e20 programmable zonal LEDs with slide-in labels plus system LEDs\u003c\/li\u003e\n\u003cli\u003ePowerful cause-and-effect programming for small sites through to large, complex multi-area systems\u003c\/li\u003e\n\u003cli\u003eInstaller-friendly auto-learn, loop detection and on-board scope facility for commissioning and fault finding\u003c\/li\u003e\n\u003cli\u003eOn-board Ethernet for AdvancedLive remote fire panel monitoring (UK and Ireland only)\u003c\/li\u003e\n\u003cli\u003eFully programmable on site from the keypad or with Advanced PC-NeT configuration software\u003c\/li\u003e\n\u003cli\u003eDisplay can be configured for virtually any language or character set, and the installer's logo can be shown using the Logo application software\u003c\/li\u003e\n\u003cli\u003eIntegral P-Bus for system expansion with optional peripheral cards\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer networking with other MxPro 5 \/ MxPro 4 panels, remote terminals and network peripherals such as BMS or graphics interfaces\u003c\/li\u003e\n\u003cli\u003eRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocol: Apollo Soteria (CoreProtocol)\u003c\/li\u003e\n\u003cli\u003eLoops: dedicated 2-8 loop control panel (6 loop cards supplied)\u003c\/li\u003e\n\u003cli\u003eDevices per loop: Apollo Soteria: up to 254 detectors\/call points per loop\u003c\/li\u003e\n\u003cli\u003eLoop current: 500 mA max per loop\u003c\/li\u003e\n\u003cli\u003eDisplay: white backlit 240 x 64 graphical LCD (5.5 x 2.5 inches)\u003c\/li\u003e\n\u003cli\u003eLED indicators: 22 red (1 x Fire, 1 x More Alarms, 20 x zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault and System)\u003c\/li\u003e\n\u003cli\u003eControls: alphanumeric keypad for navigation, Reset, Mute, Silence, Resound, Evacuate and programmable push buttons\u003c\/li\u003e\n\u003cli\u003eFire zones: 400 max across 8 loops; 2000 when networked\u003c\/li\u003e\n\u003cli\u003eOn-board sounder circuits: 8 x 1 A programmable\u003c\/li\u003e\n\u003cli\u003eOn-board relays: 4 x 1 A 30 V AC\/DC programmable (10 mA, 5 V min), expandable to 8 using 2 x MXP-507\u003c\/li\u003e\n\u003cli\u003eAuxiliary supply: 2 x 24 V 500 mA\u003c\/li\u003e\n\u003cli\u003eProgrammable inputs: 2 on-board\u003c\/li\u003e\n\u003cli\u003eProgrammable key switch inputs: 16 volt-free digital inputs\u003c\/li\u003e\n\u003cli\u003eTotal available output current: 2 x 5 A max for loop current + sounder outputs + auxiliary supply\u003c\/li\u003e\n\u003cli\u003eMains supply: 200-240 V AC 47-63 Hz (+10%, -15%), 1.4 A max\u003c\/li\u003e\n\u003cli\u003eCharger current: 2 x 2.0 A, temperature compensated\u003c\/li\u003e\n\u003cli\u003eBattery capacity: 24 V 4 Ah min to 24 V 45 Ah max internal (plus 1 x 24 V 45 Ah external with optional battery enclosure)\u003c\/li\u003e\n\u003cli\u003eEthernet: 10-Base-T \/ 100-Base-T for AdvancedLive connectivity (UK and Ireland)\u003c\/li\u003e\n\u003cli\u003eSerial ports: 2 x on-board RS232 for PC, modem, IP or portable printer\u003c\/li\u003e\n\u003cli\u003eUSB: 2 x USB type B for PC communication\u003c\/li\u003e\n\u003cli\u003eEvent log: 2 x 5000 event and diagnostic + 500 fire\u003c\/li\u003e\n\u003cli\u003eEnclosure: steel, IP30, RAL 7035\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 750 x 450 x 190 mm\u003c\/li\u003e\n\u003cli\u003eCable entry (20 mm knockouts): 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 °C to 40 °C; humidity 95% RH max\u003c\/li\u003e\n\u003cli\u003eApprovals: EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, EN 50130-4:2011 +A1:2014, EN 55032:2015, EN 62368-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced","offers":[{"title":"Default Title","offer_id":56332006228341,"sku":"MX-5806A","price":4306.34,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/6712\/8604\/files\/advanced-fire-alarms-default-title-advanced-mx-5806a-2-8-loop-fire-panel-c-w-6-loop-cards-mx-5806a-66749799137653.webp?v=1766068016"}],"url":"https:\/\/jemsystems.co.uk\/collections\/fire-alarm-panels.oembed?page=9","provider":"JEM Systems UK","version":"1.0","type":"link"}