The C-TEC QT302RXS is a slave infrared ceiling receiver for C-TEC's Quantec Addressable Call System. It is wired to a master Quantec infrared receiving device, such as an addressable infrared call point or master infrared ceiling receiver, to extend infrared coverage in bedrooms, corridors, common rooms and other areas.
Key features
- Increases infrared coverage when connected to a master Quantec infrared receiving device
- Accepts infrared calls from compatible Quantec staff attack transmitters, patient neck/wrist pendants and staff attendance pendants
- Typical 10m line-of-sight receiving range
- Up to three QT302RXS slave receivers per master
- Mounts on a standard UK 25mm single gang back box
Technical specifications
-
Order code: QT302RXS/W
-
System: C-TEC Quantec Addressable Call System
-
Receiving range: Typically 10m line of sight
-
Quiescent current: Less than 2mA
-
Connections: +V, -V, IR (wired as a slave to a Quantec addressable call point or master infrared ceiling receiver)
-
Mounting: Standard UK 25mm single gang flush or surface back box
-
Construction: Plastic
-
IP rating: IP40
-
Weight: 60g
-