Fire Detection & Alarm

Interface Modules & Isolators

294 products · Brand new, from leading brands

Shop fire alarm interface modules, loop isolators, input/output units, zone monitors, relays and intrinsically safe barriers for addressable, conventional and wireless fire alarm systems. They let your panel monitor and control plant, doors, dampers, sprinklers and other building systems.

Interface Modules & Isolators

294 products

Showing 1 - 48 of 294 products

Showing 1 - 48 of 294 products
View
FireAngel Specification Mains Powered Radio-Interlink Relay Module (WRLYM-1EU) - JEM Systems UK
FireAngel FireAngel Specification Mains Powered Radio-Interlink Relay Module (WRLYM-1EU)
Sale price£64.70
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
System Sensor M200E-SMB Surface Mounting Box - JEM Systems UKSystem Sensor M200E-SMB Surface Mounting Box - JEM Systems UK
System Sensor M201EA Single Output Module - JEM Systems UKSystem Sensor M201EA Single Output Module - JEM Systems UK
Advanced MXP-510-BX - GRAPHICS Interface (Boxed) - JEM Systems UK
Apollo SA4700-102APO Intelligent Input/Output Module - JEM Systems UK
Apollo Apollo SA4700-102APO Intelligent Input/Output Module
Sale price£48.30
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
HAES 5A 24V Double Pole IP55 Boxed Relay (REBOX24-5) - JEM Systems UK
C-TEC 24V 5A Isolatable Relay on a Plate c/w Buzzer (BF366) - JEM Systems UK
Hochiki CHQ Module Box Lid White
Hochiki Hochiki CHQ Module Box Lid White
Sale price£4.50
In stock
Fike Twinflex Input / Output Module (802-0006) - JEM Systems UK
Fike Fike Twinflex Input / Output Module (802-0006)
Sale price£64.95
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
C-TEC Auxiliary Device Isolator (BF367) - JEM Systems UK
Ziton 99202 A45E-2 Addressable Interface Module - JEM Systems UK
Apollo 55000-812APO XP95 DIN-Rail Zone Monitor Module - Isolating - JEM Systems UK
Apollo Apollo 55000-812APO XP95 DIN-Rail Zone Monitor Module - Isolating
Sale price£73.30
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
System Sensor M210EA Single Input Monitor Module - JEM Systems UKSystem Sensor M210EA Single Input Monitor Module - JEM Systems UK
Kentec KB2869 Thermal Printer Paper Roll, 57mm, 20-PackKentec KB2869 Thermal Printer Paper Roll, 57mm, 20-Pack
Cranford Controls 502-004 RIU Alarm Action IndicatorCranford Controls 502-004 RIU Alarm Action Indicator
Cranford Controls Cranford Controls 502-004 RIU Alarm Action Indicator
Sale price£8.35
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Advanced PC-NET-007 MxPro Logo Programming Software
Aico Ei128RBU Mains Relay Module with Battery Back-Up - JEM Systems UK
Aico Aico Ei128RBU Mains Relay Module with Battery Back-Up
Sale price£61.80
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Hispec Mains Powered Switch Input Module with Rechargeable Backup Battery (HSSA/INPUTMODULE) - JEM Systems UK
Hispec Hispec Mains Powered Switch Input Module with Rechargeable Backup Battery (HSSA/INPUTMODULE)
Sale price£17.95
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
AirSense Addressable Panel Interface Card (APIC) (Apollo Protocol) (9-30430) - JEM Systems UK
AirSense AirSense Addressable Panel Interface Card (APIC) (Apollo Protocol) (9-30430)
Sale price£242.10
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
AirSense Addressable Panel Interface Card (APIC) (Ziton Protocol) (9-30437) - JEM Systems UK
AirSense AirSense Addressable Panel Interface Card (APIC) (Ziton Protocol) (9-30437)
Sale price£210.00
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Aico Ei413 RadioLINK Panel Interface Module - JEM Systems UK
Aico Aico Ei413 RadioLINK Panel Interface Module
Sale price£65.85
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Hochiki Z7728+ Shunt Diode Safety Barrier for IFD-E(IS)
Hochiki Hochiki Z7728+ Shunt Diode Safety Barrier for IFD-E(IS)
Sale price£83.05
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
AirSense Addressable Panel Interface Card (APIC) (Notifier Protocol) (9-30433) - JEM Systems UK
AirSense AirSense Addressable Panel Interface Card (APIC) (Notifier Protocol) (9-30433)
Sale price£140.05
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Espire RF Module for Lithium Battery Powered Alarms (ES1RF2) - JEM Systems UK
Espire Espire RF Module for Lithium Battery Powered Alarms (ES1RF2)
Sale price£50.80
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Apollo 29600-378 Conventional I.S. Galvanic Barrier - JEM Systems UK
Honeywell Y72221-L4 - JEM Systems UK
Honeywell Honeywell Y72221-L4 Intrinsic safety galvanic isolation unit
Sale price£667.30
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Lumi-Plugin Mains Powered Radio-Interlink Relay with 10 Year Backup Battery (LPRLY9004) - JEM Systems UK
Lumi-Plugin Lumi-Plugin Mains Powered Radio-Interlink Relay with 10 Year Backup Battery (LPRLY9004)
Sale price£61.85
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Nittan Evolution SCI-6 Isolator Single Back Box (SCI-6BackBox) - JEM Systems UK
Nittan Nittan Evolution SCI-6 Isolator Single Back Box (SCI-6BackBox)
Sale price£6.60
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Aico Ei129 Switched Input Module with Battery Back-Up - JEM Systems UK
Aico Aico Ei129 Switched Input Module with Battery Back-Up
Sale price£39.55
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Zeta Fyreye MKII Addressable Isolator Base and Cover (MKII-ISO) - JEM Systems UK
Zeta Zeta Fyreye MKII Addressable Isolator Base and Cover (MKII-ISO)
Sale price£15.75
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Hochiki FIRElink APIC Addressable Interface Card (FL-APIC) - JEM Systems UK
Hochiki Hochiki FIRElink APIC Addressable Interface Card (FL-APIC)
Sale price£219.60
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Hochiki Z728 Shunt Diode Safety Barrier for IFD-E(IS)
Hochiki Hochiki Z728 Shunt Diode Safety Barrier for IFD-E(IS)
Sale price£83.05
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Hochiki Conventional Shunt Diode Safety Barrier (Z787) - JEM Systems UK
Hochiki Hochiki Conventional Shunt Diode Safety Barrier (Z787)
Sale price£109.35
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Apollo Conventional Intrinsically Safe Galvanic Barrier 1 Channel Solenoid Driver
Apollo Apollo Conventional Intrinsically Safe Galvanic Barrier 1 Channel Solenoid Driver
Sale price£427.85
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Apollo 29600-240 DIN-Rail Interface Enclosures - JEM Systems UK
AirSense Addressable Panel Interface Card (APIC) (Hochiki Protocol) (9-30438) - JEM Systems UK
AirSense AirSense Addressable Panel Interface Card (APIC) (Hochiki Protocol) (9-30438)
Sale price£126.30
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Apollo 55000-855APO XP95 Protocol Translator [SIL2] - JEM Systems UK
Apollo 29600-098 XP95 I.S. Galvanic Barrier - JEM Systems UK
Honeywell IST200E - JEM Systems UK
Honeywell Honeywell IST200E Intrinsic safety translation module complete
Sale price£289.05
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Advanced 20-BMB100-BX Plastic Mounting Box
Ziton SMB-DIN1 Surface Box for A Series Modules IP66 - Small - JEM Systems UK
Apollo 55000-856APO XP95 Protocol Translator - Dual Channel [SIL2] - JEM Systems UK
Apollo Apollo 55000-856APO XP95 Protocol Translator - Dual Channel [SIL2]
Sale price£143.45
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Apollo 29600-239 DIN-Rail Interface Enclosures - JEM Systems UK
Notifier Europe NFX-DRS-1 - JEM Systems UK
Notifier Europe Notifier NFX-DRS-1 BS7273 Door Release System
Sale price£132.85
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.

About Interface Modules & Isolators

Shop fire alarm interface modules, loop isolators, input/output units, zone monitors, relays and intrinsically safe barriers for addressable, conventional and wireless fire alarm systems. They let your panel monitor and control plant, doors, dampers, sprinklers and other building systems.

Interface modules and isolators we stock

Shop by brand: Apollo, Hochiki, Notifier, Advanced, Edwards, Zeta and FireClass.

How to choose

  • Match the protocol: addressable modules must suit your panel's protocol, such as Apollo XP95, Hochiki ESP or Notifier.
  • Input, output or both: inputs monitor contacts such as sprinkler flow switches; outputs switch or signal plant, door holders and dampers.
  • Check contact ratings: use a mains-rated module or relay when switching 230V loads.
  • Plan isolation: fit isolators, or modules with built-in isolators, so a short circuit only affects a small section of the loop.
  • Mounting: choose boxed, DIN-rail or flush versions, and add the correct back box or enclosure.

Why buy from JEM Systems UK

JEM Systems UK supplies genuine Apollo, Hochiki, Notifier and Advanced products, all brand new and factory sealed, to trade installers across the UK. Order modules alongside fire alarm panels and detector bases, with fast, tracked UK delivery.

Fire alarm interface FAQs

What is a fire alarm interface?

A fire alarm interface is a module that connects the fire alarm system to other equipment, monitoring inputs such as switches and controlling outputs such as relays, sounder circuits or plant shutdown.

What does a loop isolator do?

A loop isolator disconnects the section of an addressable loop where a short circuit occurs, so devices on the rest of the loop keep working.

What is an IS barrier?

An intrinsically safe (IS) barrier limits the energy that can reach devices in a hazardous area. Use the barrier specified for your detectors and system.

Can I use any interface module with my panel?

No. Addressable modules only work with panels that use the same protocol, so check compatibility with the panel manufacturer before ordering.

Recently viewed