Twin spot emergency lights use two adjustable LED heads to light escape routes and open areas when the mains supply fails. They suit warehouses, plant rooms and other large or demanding spaces. This range includes twin spots from Advanced, CQR, Hispec, ESP and BLE.
Emergency twin spots we stock
- Advanced Twin-LED (LuxIntelligent) – wall-mounted, addressable, non-maintained projectors with two 3W LED heads, including the IP65 TLED/NM3/P/WP weatherproof version.
- CQR – IP65 twin spots in 2x250lm and 2x500lm outputs, with narrow or wide beam options and self-test versions, such as the CQR Twin Spot Self-Test 2x500lm. See CQR.
- Hispec Congo – IP65 twin spots with two adjustable 2W heads, usable in maintained or non-maintained mode, including the Congo self-test version. Browse Hispec.
- ESP Duceri – 6W IP40 twin spots for ceiling or wall mounting, including the switchable self-test model. See ESP.
- BLE – the DEVONSHIRE 6W IP20 twin spot with square heads. See BLE.
How to choose a twin spot emergency light
- Light output: higher-output models suit larger areas and higher mounting positions; check lumen output on each product page.
- IP rating: choose IP65 for damp, dusty or outdoor areas; IP20 and IP40 models suit dry indoor spaces.
- Testing: self-test and addressable models reduce manual testing. Manual-test fittings are normally tested with an emergency light test key.
- Operation: most twin spots are non-maintained; see also non-maintained emergency lighting.
Positioning and coverage should follow an emergency lighting design to BS 5266-1 and your fire risk assessment, carried out by a competent person.
Why buy from JEM Systems UK
Every product is genuine, brand new and factory sealed. JEM Systems UK is an authorised distributor of Advanced, and we supply trade customers with fast, tracked UK delivery. Explore our full emergency lighting range.
Twin spot emergency light FAQs
What is a twin spot emergency light used for?
It lights escape routes and open areas in commercial, industrial and public buildings when the mains fails. The two heads can be aimed to cover a wide area from one fitting.
Are twin spot emergency lights maintained or non-maintained?
Most are non-maintained and only light when the power fails. Some, such as the Hispec Congo, can be set to either mode.
How long do twin spot emergency lights run?
Many models in this range are rated for 3 hours in emergency mode; always check the rated duration on the product page.
How often should twin spots be tested?
A short functional test monthly and a full rated-duration test annually, with results recorded in a log book.