Shop all Notifier Europe

Notifier Europe 020-772 4-way sounder output module (1.5A Max)

SKU: 020-772Brand: Notifier Europe
4.7store rating from 106 reviews
Available to order Qty Delivery
Pre-order0Lead time 2 to 6 weeks
Price:
Sale price£183.35
220.02 inc. VAT183.35 ex VAT
Stock:
Out of Stock
Genuine stockBrand new, boxed
1 year warrantyPlus statutory rights
Secure checkoutEncrypted payments
Trade accounts30 day credit
American Express Apple Pay Google Pay KlarnaMaestroMastercard PayPalShop Pay Visa
Key featuresFull details
  • 4 monitored sounder circuits
  • Provision for an external PSU
  • 2 digital inputs
  • Common or zonal switching

Frequently bought together

Notifier Europe 020-798 - JEM Systems UK
Notifier Europe Notifier Europe 020-798 Text Insert Label Kit for IDR Series Repeater
Sale price£78.15
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Notifier Europe 020-809 - JEM Systems UK
Notifier Europe Notifier Europe 020-809 Text Insert Label Kit, ID3000 series
Sale price£80.60
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Notifier Europe 020-810 - JEM Systems UK
Notifier Europe Notifier Europe 020-810 Text Insert Label Kit for ID60
Sale price£78.15
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Notifier Europe 020-836 - JEM Systems UK
Notifier Europe Notifier Europe 020-836 Spare key (ref 901) For ID3K Panel
Sale price£11.90
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.
Notifier Europe 020-845 - JEM Systems UK
Notifier Europe Notifier Europe 020-845 ID2000/ID3000 Extended LED extension cable
Sale price£48.60
Pre-Order (Not in Stock) - Estimated Lead Time: 2-6 Weeks.

Product details

The 020-772 is a 4-way sounder output card for Notifier NFS2-8 conventional fire alarm panels (also listed for the Morley-IAS Horizon HRZ range). It adds 4 configurable, monitored sounder circuits with provision for an external power supply, plus 2 digital inputs. Total load is 1.5 A maximum.

Key features

  • 4 monitored sounder circuits
  • Provision for an external PSU
  • 2 digital inputs
  • Common or zonal switching

Technical specifications

  • Sounder outputs: 26-28.5 V DC
  • DIP switch 6 set for loads above 250 mA: 4 x 1 A (maximum 1.5 A in total for 2 or more outputs)
  • DIP switch 6 set for loads below 250 mA: 4 x 250 mA
  • Digital inputs: 2 x 5-32 V DC
  • Sounder PCB input: 20-30 V DC, 5 A
  • Current: quiescent 47 mA, alarm/all active 1547 mA

Datasheet

Notifier Europe 020-772 4-way sounder output module (1.5A Max) Need the datasheet? Our team will email it to you. Request datasheet